PubMed Health⌕ Search

Biomedical subjects

Stephan Windecker

Publications and source records attributed to Stephan Windecker.

42 records · Page 3Linked to original sources

Effect of endurance training on coronary artery size and function in healthy men: an invasive followup study.

In eight healthy male volunteers (cardiologists; age 36 +/- 5 yr), bicycle spiroergometry, Doppler echocardiography, and quantitative coronary angiography with intracoronary Doppler measurements before and after completion of a physical endurance exercise program of >5 mo duration were performed. Maximum oxygen uptake increased from 46 +/- 6 to 54 +/- 5 ml x kg(-1) x min(-1) (P = 0.04), maximum ergometric workload changed from 3.8 +/- 0.3 to 4.4 +/- 0.3 W/kg (P = 0.001), and left ventricular mass index increased from 82 +/- 18 to 108 +/- 29 g/m(2) (P = 0.001). The right, left main, and left anterior descending coronary artery cross-sectional area increased significantly in response to exercise. Before versus at the end of the exercise program, flow-induced left anterior descending coronary artery cross-sectional area was 10.1 +/- 3.5 and 11.0 +/- 3.9 mm(2), respectively (P = 0.03), nitroglycerin-induced left coronary calibers increased significantly, and coronary flow velocity reserve changed from 3.8 +/- 0.8 to 4.5 +/- 0.7 (P = 0.001). Left coronary artery correlated significantly with ventricular mass and maximum oxygen uptake, and coronary flow velocity reserve was significantly associated with maximum workload.

Adenosine↗

Novel femoral artery puncture closure device in patients undergoing interventional and diagnostic cardiac procedures.

BACKGROUND: The wide range of closure devices for arterial access sites still leaves room for improvement. METHODS AND RESULTS: We report our initial experience with a novel, cost-effective, suture-mediated device (6 French X-PRESS device, X-SITE Medical, Blue Bell, Pennsylvania) for closure of the arterial access site after both diagnostic and therapeutic interventions. A total of 51 consecutive patients are reported. The closure was performed immediately after the procedure. No patient had more than 5,000 U heparin administered during the procedure. The closure device was used in 36 patients (73%) after diagnostic angiography and in 15 patients (27%) after therapeutic intervention. The device could be successfully deployed in 48 patients (94%). In the remaining 3 cases (6%), hemostasis was achieved with standard manual compression without any further event. Immediate total hemostasis was achieved with the device in 44 of 48 patients (92%). Four devices (8%) could not be deployed correctly due to technical problems and the patients needed additional manual compression. The average time to achieve complete hemostasis was 5.5 +/- 3.5 minutes (range, 3-26 minutes). The patients were ambulated after a period of 1.3 +/- 0.4 hours of bedrest (range, 0.8-3.5 hours). Time to possible discharge was 4.2 +/- 3.4 hours (range, 0.9-12.5 hours). One patient experienced a minor complication (hematoma < 6 cm) and was treated with manual compression without clinical sequelae. Telephone follow-up was carried out 2 weeks after deployment and revealed no sequelae. CONCLUSION: The 6 French X-PRESS device is safe and effective in providing rapid hemostasis following interventional or diagnostic catheterization procedures. Use of the device is associated with a low rate of complications and facilitates quick hemostasis, mobilization and discharge.

Aged↗

Five French versus 6 French PCI: a case control study of efficacy, safety and outcome.

We report our experience of percutaneous coronary intervention (PCI) with 5 French (Fr) guiding catheters in a retrospective analysis of consecutive cases undergoing ad hoc PCI. Results were compared with a cohort of 6 Fr PCI cases matched for age, sex and operator over the same study period. A total of 210 patients (311 lesions) underwent PCI using 5 Fr guiding catheters and 174 matched patients (300 lesions) underwent PCI with 6 Fr guiding catheters. Multivessel PCI was performed in 18% of patients in the 5 Fr group and in 26% of the 6 Fr group (p = 0.046). There was no difference in clinical, angiographic or procedural characteristics between groups. Technical success rate was superior in the 5 Fr group compared with the 6 Fr (99% versus 95%; p = 0.03). The rate of stent implantation did not differ and the 5 Fr guiding catheter did not prohibit the use of large or long stents/balloons. Failure of 5 Fr PCI in 3 cases was not due to inadequate guiding catheter support. In-hospital major adverse cardiac events (MACE) and serious femoral complications were rare and at 6-month follow-up did not differ between groups. However, compared with 6 Fr PCI, procedure time and contrast medium usage was significantly less in the 5 Fr group (contrast: 274 +/- 101 ml versus 313 +/- 124 ml; p = 0.0008; fluoroscopy time: 16 +/- 9 minutes versus 19 +/- 12 minutes; p = 0.006). We conclude that the use of 5 Fr guiding catheters is effective and safe in unselected patients undergoing PCI and may even confer certain advantages. The 5 Fr approach can be recommended for routine interventional practice.

Adult↗

Thrombin activatable fibrinolysis inhibitor (TAFI) levels in patients with coronary artery disease investigated by angiography.

Due to its role in the balance between coagulation and fibrinolysis, thrombin activatable fibrinolysis inhibitor (TAFI) may be involved in the development of cardiovascular diseases. We studied 362 patients with coronary artery disease (CAD) and 134 control subjects free of CAD, both groups investigated by angiography. TAFI antigen levels were determined in venous and intracoronary plasma samples and were related to metabolic and hemostatic risk factors and extent of coronary atherosclerosis. Venous TAFI levels tended to be higher in CAD patients compared to controls, whereas this difference was significant in intracoronary samples. A subgroup of patients who had not experienced acute myocardial infarction or undergone previous cardiac interventions showed significantly higher TAFI levels in both venous and intracoronary plasma samples. TAFI levels correlated with acute phase reactants indicating a role for TAFI in inflammation. However, TAFI levels did not correlate with extent of coronary atherosclerosis and among the classical cardiovascular risk factors TAFI levels only correlated with total cholesterol and fibrinogen concentration. Our results suggest that TAFI might be a risk factor for the development of CAD.

Acute-Phase Proteins↗

Treatment of Restenosis.

Restenosis constitutes the major limitation to the effectiveness of percutaneous coronary intervention. The advent of stent placement has engendered an even more difficult-to-treat entity: in-stent restenosis. Restenosis should be treated with repeat balloon angioplasty. Some patients with focal restenosis in large caliber vessels benefit from stent implantation. In the setting of diffuse in-stent restenosis, debulking techniques such as rotational atherectomy have been considered, but proof of efficacy is lacking. Despite a favorable acute procedural outcome, restenosis after repeat angioplasty develops in 32% to 37% of the treated patients. Therefore, combatting restenosis should focus on prevention. Intracoronary brachytherapy and drug- eluting stents have emerged as promising new tools to help prevent the development of restenosis.

Journal Article↗

Nonpharmacologic Therapy of Atrial Fibrillation and Atrial Flutter.

The medical therapy of atrial fibrillation and atrial flutter is unsatisfactory for many patients since nonpharmacologic therapy is often necessary. Curative catheter ablation is the treatment of choice for atrial flutter. Primary success rates of 95% are routinely achieved in centers of excellence with relapse rates for atrial flutter of 5%-10%. Nonpharmacologic therapies in atrial fibrillation are more often palliative than curative. Catheter ablation of the AV junction with implantation of a permanent pacemaker is the primary nonpharmacologic therapy for medically refractory atrial fibrillation. The quality of life is improved by AV junction ablation, although survival is not. Curative therapy for atrial fibrillation is available with the surgical maze operation but that is primarily offered in conjunction with concomitant cardiac surgery. Recently a catheter ablative procedure to mimic the maze operation has had preliminary evaluation but remains investigational. A focal ablation procedure for paroxysmal atrial fibrillation has also entered into clinical trials.

Journal Article↗