Measures of performance in nonlinear estimation tasks: prediction of estimation performance at low signal-to-noise ratio.

Maximum-likelihood (ML) estimation is an established paradigm for the assessment of imaging system performance in nonlinear quantitation tasks. At high signal-to-noise ratio (SNR), ML estimates are asymptotically Gaussian-distributed, unbiased and efficient, thereby attaining the Cramer-Rao bound (CRB). Therefore, at high SNR the CRB is useful as a predictor of the variance of ML estimates and, consequently, as a basis for measures of estimation performance. At low SNR, however, the achievable parameter variances are often substantially larger than the CRB and the estimates are no longer Gaussian-distributed. These departures imply that inference about the estimates that is based on the CRB and the assumption of a normal distribution will not be valid. We have found previously that for some tasks these effects arise at noise levels considered clinically acceptable. We have derived the mathematical relationship between a new measure, chi2(pdf-ML), and the expected probability density of the ML estimates, and have justified the use of chi2(pdf-ML)-isocontours in parameter space to describe the ML estimates. We validated this approach by simulation experiments using spherical objects imaged with a Gaussian point spread function. The parameters, activity concentration and size, were estimated simultaneously by ML, and variances and covariances calculated over 1000 replications per condition from 3D image volumes and from 2D tomographic projections of the same object. At low SNR, where the CRB is no longer achievable, chi2(pdf-ML)-isocontours provide a robust prediction of the distribution of the ML estimates. At high SNR, the chi2(pdf-ML)-isocontours asymptotically approach the analogous chi2(pdf-F)-contours derived from the Fisher information matrix. The chi2(pdf-ML) model appears to be suitable for characterization of the influence of the noise level and characteristics, the task, and the object on the shape of the probability density of the ML estimates at low SNR. Furthermore, it provides unique insights into the causes of the variability of estimation performance.

Algorithms↗

Collimator optimization for detection and quantitation tasks: application to gallium-67 imaging.

We describe a new approach to the problem of collimator optimization in nuclear medicine; our methodology is illustrated for the challenging case of gallium-67 imaging. Collimator-design methods based on empirical rules, such as specification of an allowable level of single-septal penetration (SSP) at a fixed energy, are especially inappropriate for radionuclides characterized by an abundance of high-energy contaminant photons that scatter in the patient, collimator, and/or detector before detection within one of a few photopeak energy windows. Lead X-rays produced in the collimator are an additional source of contamination. We designed optimal collimation for 67Ga based on relevant clinical imaging tasks and a realistic simulation of photon transport in a phantom, collimator, and detector. Collimator designs were compared on the basis of performance in lesion detection, as predicted by a three-channel Hotelling observer (CHO), as well as in tumor and background activity estimation (EST), quantified by task-specific signal-to-noise ratios (SNRs). The optimal values of collimator lead content were 22.0 and 23.8 g/cm2, respectively, for CHO and EST, while the optimal geometric resolution values were 1.8 and 1.6 cm full-width at half-maximum (FWHM), respectively, at a distance of 23.5 cm. The resolution of a commercially available medium-energy low-penetration collimator (MELP) is 1.9 cm FWHM at this distance. The optimal values for SSP at 300 keV were 7.3% and 5.8% based on CHO and EST, respectively, compared to 5.2% for the MELP collimator. Compared with the commercial MELP collimator, the 67Ga collimator optimized for tumor detection or activity estimation tasks provided improved geometric spatial resolution with reduced geometric efficiency and, surprisingly, allowed an increased level of single-septal penetration.

Citrates↗

Brain SPECT with short focal-length cone-beam collimation.

Single-photon emission-computed tomography (SPECT) imaging of deep brain structures is compromised by loss of photons due to attenuation. We have previously shown that a centrally peaked collimator sensitivity function can compensate for this phenomenon, increasing sensitivity over most of the brain. For dual-head instruments, parallel-hole collimators cannot provide variable sensitivity without simultaneously degrading spatial resolution near the center of the brain; this suggests the use of converging collimators. We have designed collimator pairs for dual-head SPECT systems to increase sensitivity, particularly in the center of the brain, and compared the new collimation approach to existing approaches on the basis of performance in estimating activity concentration of small structures at various locations in the brain. The collimator pairs we evaluated included a cone-beam collimator, for increased sensitivity, and a fan-beam collimator, for data sufficiency. We calculated projections of an ellipsoidal uniform background, with 0.9-cm-radius spherical lesions at several locations in the background. From these, we determined ideal signal-to-noise ratios (SNRCRB) for estimation of activity concentration within the spheres, based on the Cramer-Rao lower bound on variance. We also reconstructed, by an ordered-subset expectation-maximization (OS-EM) procedure, images of this phantom, as well as of the Zubal brain phantom, to allow visual assessment and to ensure that they were free of artifacts. The best of the collimator pairs evaluated comprised a cone-beam collimator with 20 cm focal length, for which the focal point is inside the brain, and a fan-beam collimator with 40 cm focal length. This pair yielded increased SNRCRB, compared to the parallel-parallel pair, throughout the imaging volume. The factor by which SNRCRB increased ranged from 1.1 at the most axially extreme location to 3.5 at the center. The gains in SNRCRB were relatively robust to mismatches between the center of the brain and the center of the imaging volume. Artifact-free reconstructions of simulated data acquired using this pair were obtained. Combining fan-beam and short-focusing cone-beam collimation should greatly improve dual-head brain SPECT imaging, especially for centrally located structures.

Algorithms↗

Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses.

UNLABELLED: We have addressed 2 major challenges of (82)Rb cardiac PET, noninvasive estimation of an accurate input function and absolute quantitation of myocardial perfusion, using a generalized form of least-squares factor analysis of dynamic sequences (GFADS) and a novel compartment analysis approach. METHODS: Left and right ventricular (LV + RV) time-activity curves (TACs) were generated from 10 rest/stress studies, and 30 myocardial TACs were modeled to cover a range of clinical values. Two-dimensional PET Monte Carlo simulations of the LV, RV, myocardium, and other organs were generated separately and combined using the above TACs to form 30 realistic dynamic (82)Rb studies. LV and RV TACs were estimated by GFADS and used as input to a 2-compartment kinetic analysis that estimates parametric maps of myocardial tissue extraction (k(1)) and egress (k(2)), as well as LV + RV contributions (f(v), r(v)), by orthogonal voxel grouping. In addition, 13 patients were injected with 2.22 +/- 0.19 GBq (60 +/- 5 mCi) of (82)Rb and imaged dynamically for 6 min at rest and during dipyridamole stress. RESULTS: In Monte Carlo simulations, GFADS yielded estimates of the 3 factors and corresponding factor images, with average errors of -4.2% +/- 6.3%, 3.5% +/- 4.3%, and 2.0% +/- 5.5% in the LV, RV, and myocardial factor estimates, respectively. The estimates were significantly more accurate and robust to noise than those obtained using TACs based on manually drawn volumes of interest (P < 0.01). The 2-compartment approach yielded accurate k(1), k(2), f(v), and r(v) parametric maps; the average error of estimates of k(1) was 6.8% +/- 3.6%. In all patient studies, our approach yielded robust estimates of k(1), k(2), f(v), and r(v), which correlated very well with the status of the subject and the catheterization results. CONCLUSION: Quantitative dynamic (82)Rb PET using generalized factor analysis of dynamic sequences and compartmental modeling yields estimates of parameters of absolute myocardial perfusion and kinetics with errors of <9%.

Adult↗

Quantitative SPECT leads to improved performance in discrimination tasks related to prodromal Alzheimer's disease.

UNLABELLED: We investigated the impact of the quantitation and reconstruction protocol on clinical tasks. The performance of standard clinical reconstruction procedures in discrimination tasks related to the diagnosis of prodromal Alzheimer's disease (AD) was compared with the performance of a quantitative approach incorporating improved corrections for scatter, attenuation, intrinsic spatial resolution, and distance-dependent spatial resolution. METHODS: Seventeen normal controls (normal group), 56 subjects who did not have dementia, who did have memory problems, but who did not develop AD within 5 y of follow-up (questionable group), and 27 subjects who did not have dementia, who did have memory problems, and who did develop AD over the follow-up period (converter group) were considered in this study. (99m)Tc-hexamethylpropyleneamine oxime SPECT and MRI studies were performed for each subject at baseline. The standard quantitation protocol (STD), routinely used in our clinic, consisted of Compton window scatter correction followed by filtered backprojection with attenuation correction using a uniform attenuation map. In the improved quantitative approach (QUAN), projections were corrected for scatter by use of a general spectral method and reconstructed by use of ordered-subset(s) expectation maximization, incorporating corrections for collimator response and attenuation using both a uniform attenuation map (QUANunif) and a nonuniform attenuation map (QUANnonunif). Mean SPECT activity concentration and MRI volume were estimated for 7 structures: rostral anterior cingulate gyrus, caudal anterior cingulate gyrus, posterior cingulate gyrus, hippocampus, basal forebrain, amygdala, and the banks of the superior temporal sulcus. Data were analyzed by pairwise discriminant analysis, and performance in binary group discrimination was measured by correlated receiver-operating-characteristic analysis. RESULTS: The use of QUANnonunif yielded a small but systematic improvement in discrimination accuracy for normal versus converter groups (accuracy or area under the receiver-operating-characteristic curve [Az], 0.965), normal versus questionable groups (Az, 0.973), and questionable versus converter groups (Az, 0.881) compared with the results obtained with QUANunif (Az, 0.955, 0.962, and 0.866, respectively). Discrimination performance was significantly lower (P < 0.05) with STD than with QUAN in all 3 tasks (Az with STD, 0.906, 0.878, and 0.768, respectively). MRI volume estimation led to a lower overall performance in all 3 tasks than did QUANnonunif (Az with MRI, 0.947, 0.917, and 0.872, respectively). CONCLUSION: Improved quantitative image reconstruction with accurate compensation for scatter, attenuation, and variable collimator response led to significantly better performance in discrimination tasks related to the diagnosis of prodromal AD than did standard clinical reconstruction procedures. The use of a nonuniform brain attenuation map yields a small improvement in discrimination accuracy.

Aged↗

Optimization of Ga-67 imaging for detection and estimation tasks: dependence of imaging performance on spectral acquisition parameters.

UNLABELLED: We have compared the use of two (93 and 185 keV) and three (93, 185, and 300 keV) photopeaks for Ga-67 tumor imaging and optimized the placement of each energy window. METHODS: The bases for optimization and evaluation were ideal and Bayesian signal-to-noise ratios (SNR) for the detection of spheres embedded in a realistic anthropomorphic digital torso phantom and ideal SNR for the estimation of their size and activity concentration. Seven spheres of radii ranging from 1 to 3 cm, located at several sites in the torso, were simulated using a realistic Monte Carlo program. We also calculated the ideal SNR for the detection from simple phantom acquisitions. RESULTS: For detection and estimation tasks, the optimum windows were identical for all sphere sizes and locations. For the 93 keV photopeak, the optimal window was 84-102 keV for the detection and 87-102 keV for estimation; these windows are narrower than the 20% window often used in the clinic (83-101 keV). For the 185 keV photopeak, the optimal window was 170-220 keV for the detection and 170-215 keV for estimation; these are substantially different than the 15% window used in our clinic (171-199 keV). For the 300 keV photopeak, the optimal window for detection was 270-320 keV, and for estimation, 280-320 keV. Using the three optimized, rather than only the two lower-energy, windows yielded a 9% increase in the SNR for the detection of the 3 cm diam sphere (a 12% increase for a 2 cm diam sphere) and a 7% increase in the SNR for estimation of its size. For the acquired phantom data, detection also increased by 9%-12% when using three, rather than two, energy windows.

Abdomen↗