A 96-well single-pot liquid-liquid extraction, hydrophilic interaction liquid chromatography-mass spectrometry method for the determination of muraglitazar in human plasma.

A single-pot liquid-liquid extraction (LLE) with hydrophilic interaction liquid chromatography/tandem mass spectrometry (HILIC/MS/MS) method has been developed and validated for the determination of muraglitazar, a hydrophobic diabetes drug, in human plasma. To 0.050 ml of each plasma sample in a 96-well plate, the internal standard solution in acetonitrile and toluene were added to extract the compound of interest. The plate was vortexed, followed by centrifugation. The organic layer was then directly injected into an LC/MS/MS system. Chromatographic separation was achieved isocratically on a Thermohypersil_Keystone, Hypersil silica column (3 mmx50 mm, 3 microm). The mobile phase contained 85% of methyl t-butyl ether and 15% of 90/10 (v/v) acetonitrile/water with 0.3% trifluoroacetic acid. Post-column mobile phase of 50/50 (v/v) acetonitrile/water containing 0.1% formic acid was added. Detection was by positive ion electrospray tandem mass spectrometry on a Sciex API 4000. The standard curve, ranged from 1 to 1000 ng/ml, was fitted to a 1/x weighted quadratic regression model. This single-pot LLE approach effectively eliminated time-consuming organic layer transfer, dry-down, and sample reconstitution steps, which are essential for a conventional liquid-liquid extraction procedure. The modified mobile phase was more compatible with the direct injection of the commonly used extraction solvents in LLE. Furthermore, the modified mobile phase improved the retention of muraglitazar, a hydrophobic compound, on the normal phase silica column. The validation results demonstrated that this method was rugged and suitable for analyzing muraglitazar in human plasma. In comparison with a revised-phase LC/MS/MS method, this single-pot LLE, HILIC/MS/MS method improved the detection sensitivity by more than four-fold based upon the LLOQ signal to noise ratio. This approach may be applied to other hydrophobic compounds with proper modification of the mobile phase compositions.

Chromatography, Liquid↗

A 96-well single-pot protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of muraglitazar, a novel diabetes drug, in human plasma.

A 96-well single-pot protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of muraglitazar, a PPAR alpha/gamma dual agonist, in human plasma. The internal standard, a chemical analogue, was dissolved in acetonitrile containing 0.1% formic acid. The solvent system was also served as a protein precipitation reagent. Human plasma samples (0.1 mL) and the internal standard solution (0.3 mL) were added to a 96-well plate. The plate was vortexed for 1 min and centrifuged for 5 min. Then the supernatant layers were directly injected into the LC/MS/MS system. The chromatographic separation was achieved isocratically on a Phenomenox C18(2) Luna column (2 mm x 50 mm, 5 microm). The mobile phase contained 20/80 (v/v) of water and acetonitrile containing 0.1% formic acid. Detection was by positive ion electrospray tandem mass spectrometry on a Sciex API 3000. The standard curve, which ranged from 1 to 1000 ng/mL, was fitted to a 1/x weighted quadratic regression model. This single-pot approach effectively eliminated three time consuming sample preparation steps: sample transfer, dry-down, and reconstitution before the injection, while it preserved all the benefits of the traditional protein precipitation. By properly adjusting the autosampler needle offset level, only the supernatant was injected, without disturbing the precipitated proteins in the bottom. As a result, the quality of chromatography and column life were not compromised. After more than 600 injections, there was only slightly increase of column back-pressure. The validation results demonstrated that this method was rugged and provide satisfactory precision and accuracy. The method has been successfully applied to analyze human plasma samples in support of a first-in-man study. This method has also been validated in monkey and mouse plasma for the determination of muraglitazar.

Animals↗

Automated Tecan programming for bioanalytical sample preparation with EZTecan.

This paper reports the first successful automated Tecan (Tecan US, Research Triangle Park, NC) programming for bioanalytical sample analysis with an in-house developed software, called EZTecan. Based on the sample run list in the Watson Laboratory Information Management System (InnaPhase Corp., Philadelphia, PA), EZTecan can generate a Tecan program for bioanalytical sample preparation, including sample transfer, sample dilution, extraction, and reconstitution. Many built-in functions for EZTecan ensure the flexibility, quality, and efficiency of the liquid handling. It takes about 90 min to prepare two 96-well plates from sample transfer to reconstitution. Analytical results shown good inter- and intra-assay accuracy and precision, which meet the +/-15% Good Laboratory Performance acceptance criteria. With EZTecan, bioanalysts can prepare samples without writing a single line of Tecan program.

Automation↗

Quantitative determination of pioglitazone in human serum by direct-injection high-performance liquid chromatography mass spectrometry and its application to a bioequivalence study.

A simple, high throughput, direct-injection high-performance liquid chromatography tandem mass spectrometry method (LC/MS/MS) has been developed and validated for the quantitation of pioglitazone in human serum. After mixing the internal standard with a sample, a 10 microl portion of the mixture was directly injected into a high-flow LC/MS/MS system, which included an extraction column, an analytical column and a six-port switching valve. The on-line extraction was achieved on an Oasis HLB column (1 mm x 50 mm, 30 microm) with a 100% aqueous loading mobile phase containing 5 mM ammonium acetate (pH 4.0) at a flow rate of 4 ml/min. The extracted analyte was eluted by a mobile phase which contained 5 mM ammonium acetate and acetonitrile. The analytical column was a Luna C18 column (4.6 mm x 50 mm, 5 microm). Detection was achieved by positive ion electrospray tandem mass spectrometry. The lower limit of quantitation of the method was 9 ng/ml. The standard curve, which ranged from 9 to 1350 ng/ml, was fitted by a weighted (1/x2) quadratic regression model. The validation results demonstrated that this method had satisfactory precision and accuracy across the calibration range. There was no evidence of instability of the analyte in human serum following three freeze-thaw cycles, and samples could be stored for at least 2 weeks at -30 degrees C. This method was used to analyze pioglitazone concentrations in human serum samples from a bioequivalence study of a blinded Actos formulation (encapsulated 15 mg tablet) and an Actos 15 mg tablet. The blinded formulation was shown to be bioequivalent to an Actos 15 mg tablet.

Calibration↗

Development and validation of a liquid chromatography-mass spectrometric method for the determination of DPC 423, an antithrombotic agent, in rat and dog plasma.

A sensitive and selective LC-MS-MS method for the determination of DPC 423 (I), an antithrombotic agent, is described. This method used a solid-phase extraction from 0.1 ml plasma with an Isolute C(2) cartridge. HPLC separation was carried out on a YMC ODS-AQ C(18) column (50x2 mm) at a flow-rate of 300 microliter/min with an analysis time of 5 min. Compounds were eluted using a mobile phase of H(2)O/CH(3)CN/HCOOH: 66:34:0.1 (v/v/v), pH 4.0. A structural analogue of I was used as the internal standard to account for variations in recovery and instrument response. Mass spectrometric detection was carried out with a PE Sciex API III(+) triple quadrupole mass spectrometer equipped with a Turbo IonSpray source as the LC-MS interface. Good intra-day and inter-day assay precision (<10% CV) and accuracy (<10% difference) were observed over a concentration range of 0.005-2.5 microM in plasma. The extraction recoveries were approximately 90% and the method was found to be linear for the assay (r(2)>0.999). The method has been successfully applied to discovery and preclinical pharmacokinetic studies, including a dose range-finding study and toxicokinetic exposure studies in rat and dog.

Adsorption↗

Effects of increased lipid concentration and hyperemic blood flow on the intrinsic myocardial washout kinetics of (99m)TcN-NOET.

UNLABELLED: Bis(N-ethoxy,N-ethyldithiocarbamato)nitrido technetium (V) ((99m)Tc) ((99m)TcN-NOET) is a myocardial perfusion imaging agent demonstrating significant redistribution and currently in phase III clinical trials. Previous studies have suggested that (99m)TcN-NOET is bound intravascularly. Therefore, we sought to determine whether modifications in the vascular compartment would provide further insights into the mechanisms of (99m)TcN-NOET myocardial washout and redistribution. METHODS: (99m)TcN-NOET cardiac washout was studied ex vivo in 15 isolated perfused rat hearts after bolus injection (1.5 MBq) in the absence (n = 6) or presence of bovine serum albumin ([BSA] 0.03%) with (n = 5) or without (n = 4) bound lipids. The intrinsic myocardial washout of the tracer was also studied in vivo in 6 dogs after intracoronary bolus injection of the tracer (0.75 MBq) before and after hyperlipidemia induced by intravenous administration of 300 mL of 20% intralipids (n = 3) or hyperemia induced by intravenous infusion of the adenosine A(2A) receptor agonist ATL-146e (0.3 micro g/kg/min; n = 6). RESULTS: On isolated hearts, there was no significant myocardial washout of (99m)TcN-NOET with Krebs-Henseleit buffer. Addition of BSA without bound lipids resulted in a significant cardiac washout of the tracer (P < 0.001 by repeated measures ANOVA). The presence of lipids bound to BSA further accelerated the washout rate of (99m)TcN-NOET (half-life [t(1/2)], 431.5 +/- 23.2 min vs. 242.9 +/- 63.2 min; P < 0.05). In vivo in dogs, intralipid administration significantly increased the intrinsic washout rate of (99m)TcN-NOET (t(1/2), 108.0 +/- 23.9 min vs. 51.8 +/- 11.8 min; P < 0.05). In addition, vasodilatation with ATL-146e resulted in a 4.9-fold increase in coronary flow (P < 0.05 vs. baseline) and a significantly faster intrinsic (99m)TcN-NOET myocardial washout (t(1/2), 81.1 +/- 12.1 min vs. 40.7 +/- 7.3 min; P < 0.05). CONCLUSION: The myocardial washout kinetics of (99m)TcN-NOET are affected by a variety of intravascular factors, supporting the hypothesis that the tracer is most likely localized on the vascular endothelium. The potential impact of variations in circulating lipid levels among patients on clinical imaging with (99m)TcN-NOET requires further investigation.

Animals↗

Novel direct detection method for quantitative determination of intracellular nucleoside triphosphates using weak anion exchange liquid chromatography/tandem mass spectrometry.

A novel analytical method has been developed for direct quantification of intracellular nucleoside triphosphates (NTPs). Lysates of human peripheral blood mononuclear cells (PBMCs) were extracted by protein precipitation, and the filtered extracts were analyzed by weak anion exchange liquid chromatography (WAX-LC) coupled to detection by mass spectrometry (MS). Compared with ion pairing (IP)-LC/MS/MS, the only MS-compatible direct detection method for NTPs currently available, the new method completely avoids the usage of ion-pairing reagents and has a shorter analytical time of only 2 min. The method was validated and is being used to determine the amount of the triphosphate metabolite of D-D4FC (DPC817), an investigational HIV nucleoside reverse transcriptase inhibitor (NRTI), in human PBMC samples from clinical studies. By using a PE Sciex API 4000 triple quadrupole instrument operating in positive ion MRM mode, the method was able to achieve a lower limit of quantitation (LLOQ) of 5 fmol/10(6) cells in samples containing 3 x 10(6) lysed cells (6 fmol on-column). With minor adaptation, the method described here may be suitable for analyzing other NTPs. This paper also provides a discussion of the unique retention characteristics of WAX-LC, the principles of which may prove to be valuable for designing other forms of directly coupled ion-exchange (IX)-LC/MS methods suited for high sensitivity quantitative analysis.

Chromatography, Liquid↗