Publications and source records attributed to T Dudykevych.

7 recordsLinked to original sources

Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT.

The increasing use of EIT in clinical research on severely ill lung patients requires a clarification of the influence of pathologic impedance distributions on the validity of the resulting tomograms. Significant accumulation of low-conducting air (e.g. pneumothorax or emphysema) or well-conducting liquid (e.g. haematothorax or atelectases) may conflict with treating the imaging problem as purely linear. First, we investigated the influence of stepwise inflation and deflation by up to 300 ml of air and 300 ml of Ringer solution into the pleural space of five pigs on the resulting tomograms during ventilation at constant tidal volume. Series of EIT images representing relative impedance changes were generated on the basis of a modified Sheffield back projection algorithm and ventilation distribution was displayed as functional (f-EIT) tomograms. In addition, a modified simultaneous iterative reconstruction technique (SIRT) was applied to quantify the resistivity distribution on an absolute level scaled in Omega m (a-EIT). Second, we applied these two EIT techniques on four intensive care patients with inhomogeneous air and fluid distribution and compared the EIT results to computed tomography (CT) and to a reference set of intrathoracic resistivity data of 20 healthy volunteers calculated by SIRT. The results of the animal model show that f-EIT based on back projection is not disturbed by the artificial pneumo- or haematothorax. Application of SIRT allows reliable discrimination and detection of the location and amplitude of pneumo- or haematothorax. These results were supported by the good agreement between the electrical impedance tomograms and CT scans on patients and by the significant differences of regional resistivity data between patients and healthy volunteers.

Algorithms↗

Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomography.

BACKGROUND: We hypothesized, that in mechanically ventilated patients with acute respiratory failure, regional pressure volume curves differ markedly from conventional global pressure volume curves of the whole lung. METHODS: In nine mechanically ventilated patients with acute respiratory failure during an inspiratory low-flow manoeuvre, conventional global pressure volume curves were registered by spirometry and regional pressure volume curves in up to 912 regions were assessed simultaneously using electrical impedance tomography. We compared the lower (LIP) and upper (UIP) inflection points obtained from the conventional global pressure volume curve and regional pressure volume curves. RESULTS: We identified from the conventional global pressure volume curves LIP [3-11 (8) cmH2O] in eight patients and UIP [31-39 (33) cmH2O] in three patients. Using electrical impedance tomography (EIT), LIP [3-18 (8) cmH2O] in 54-264 (180) regions and UIP [23-42 (36) cmH2O] in 149-324 (193) regions (range and median) were identified. Lung mechanics measured by conventional global pressure volume curves are similar to the median of regional pressure volume curves obtained by EIT within the tomographic plane. However, single regional pressure volume curves differ markedly with a broad heterogeneity of lower and upper inflection points. CONCLUSION: Lower and upper inflection points obtained from conventional global pressure volume curves are not representative of all regions of the lungs.

Acute Disease↗

Effect of positive end-expiratory-pressure on regional ventilation in patients with acute lung injury evaluated by electrical impedance tomography.

BACKGROUND AND OBJECTIVE: For the treatment of patients with adult respiratory distress syndrome and acute lung injury bedside measurements of regional lung ventilation should be considered for optimizing ventilatory settings. The aim was to investigate the effect of positive end-expiratory pressure (PEEP) on regional ventilation in mechanically ventilated patients at the bedside by electrical impedance tomography. METHODS: Eight mechanically ventilated patients were included in the study. PEEP levels were increased from 0 to 5, 10, 15 mbar and back to 0 mbar. Regional ventilation in 912 regions of the thorax was investigated at each PEEP by electrical impedance tomography. The obtained regions were divided in four groups: none (none and poorly ventilated regions including chest wall and mediastinum), bad, moderate and well-ventilated regions. RESULTS: Increasing the PEEP stepwise from 0 to 15 mbar decreased the non-ventilated regions (none: 540 regions at PEEP 0 and 406 regions at PEEP 15). In contrast, the other regions increased (bad: 316 regions at PEEP 0 and 380 regions at PEEP 15; moderate: 40 regions at PEEP 0 and 100 regions at PEEP 15; well: 0 region at PEEP 0 and 34 regions at PEEP 15 (median values)) indicating an improvement of regional ventilation. CONCLUSIONS: Increasing PEEP in mechanically ventilated patients reduces none ventilated regions (atelectasis). Furthermore, it leads to a shift from none and bad ventilated regions to moderately and well-ventilated regions. Electrical impedance tomography is a bedside technique and might be an alternative to computed tomography scan to assess aerated lung regions.

Acute Disease↗

Impedance analyser module for EIT and spectroscopy using undersampling.

In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware for voltage and current measurement, early signal digitization and subsequent digital signal processing in order to calculate the components of impedance (or admittance). At low frequencies, the module utilizes the conventional direct conversion method, whereas at high frequencies the undersampling technique is used. The advantages of the described system are the following: (a) the frequency range is extended to higher frequencies, (b) the number of data sampled per time interval is significantly reduced, and (c) the current consumption and the costs of the ADCs can be significantly reduced. The validation procedure is performed by comparing the measured and theoretical values of the magnitude and the phase of the impedance for a commonly used tissue model. The module offers an accuracy of better than 0.012% for the magnitude of impedance and better than 0.02 degrees for the phase.

Electric Impedance↗

Gravity effects on regional lung ventilation determined by functional EIT during parabolic flights.

Gravity-dependent changes of regional lung function were studied during normogravity, hypergravity, and microgravity induced by parabolic flights. Seven healthy subjects were followed in the right lateral and supine postures during tidal breathing, forced vital capacity, and slow expiratory vital capacity maneuvers. Regional 1) lung ventilation, 2) lung volumes, and 3) lung emptying behavior were studied in a transverse thoracic plane by functional electrical impedance tomography (EIT). The results showed gravity-dependent changes of regional lung ventilation parameters. A significant effect of gravity on regional functional residual capacity with a rapid lung volume redistribution during the gravity transition phases was established. The most homogeneous functional residual capacity distribution was found at microgravity. During vital capacity and forced vital capacity in the right lateral posture, the decrease in lung volume on expiration was larger in the right lung region at all gravity phases. During tidal breathing, the differences in ventilation magnitudes between the right and left lung regions were not significant in either posture or gravity phase. A significant nonlinearity of lung emptying was determined at normogravity and hypergravity. The pattern of lung emptying was homogeneous during microgravity.

Adult↗

Quantitative evaluation of the performance of different electrical tomography devices.

Two widely used electrical tomography systems, the Sheffield Mark I and the DAS-01P, were quantitatively evaluated and compared to the newly developed Goe-MF system. The performance was quantified using a hardware phantom which closely matches the real input and transfer impedances of the human thorax and allows measurements equivalent to different states of lung inflation. Our results demonstrate that adequate averaging is necessary for noise reduction for the Mark I and especially for the DAS-01P system to get meaningful results even in visualizing maximal respiratory manoeuvres. The Goe-MF system showed a notably improved signal-to-noise ratio which allows also dynamic measurements at low levels of lung volume changes, e.g., in intensive care lung injury patients.

Calibration↗

A simple method to check the dynamic performance of electrical impedance tomography systems.

The test concept as well as the design of a simple resistor phantom suitable for the evaluation of the properties of electrical impedance tomographic (EIT) systems is presented. Input and transfer impedance of the phantom are matched with those of the human thorax. Amplitude of the local impedance variations similar to in vivo conditions (ventilation) can be intentionally set to perform measurements on different states. The theoretical potential differences between the electrodes are calculated. The evaluation procedure is performed in terms of the local amplitude of the relative impedance change as well as the local distribution of noise. The whole procedure can be applied either to compare quantitatively the performance of different EIT data acquisition systems or to determine the amount of measurement disturbance caused by the external electrical environment in clinical settings.

Cardiography, Impedance↗