Plasma cholesterol: an influencing factor in red blood cell oxygen release and cellular oxygen availability.

BACKGROUND: A fairly immediate reduction in angina pectoris symptoms after cholesterol lowering has been described. Our previous findings in rabbits and in a four-patient human pilot study indicated the existence of an RBC membrane barrier to oxygen (O2) transport in the presence of hypercholesterolemia. Our current objective was to determine whether, and to what extent, the plasma cholesterol concentration is an influencing factor in RBC O2 release and cellular O2 availability. STUDY DESIGN: In an unique O2 diffusion analysis system, blood samples from 100 patients referred for lipid modification were analyzed. After 1 to 2 minutes of mixing in our diffusion analysis system, the next 1 to 2 minutes of circulation is comparable with 1 to 2 seconds of myocardial capillary flow. RBC O2 diffusion was defined by the depletion rate of total O2 content in blood from full O2 saturation (98%) to desaturation (approximately 60%). Relative tissue O2 availability was defined as the percentage decrease in O2 availability between the high-cholesterol group and the low-cholesterol group. RESULTS: The 100 patients were divided almost equally into two groups on the basis of plasma cholesterol ranges of 175 to 229 mg/dL (n=49) and 230 to 299 mg/dL (n = 51). The mean cholesterol concentrations and percentage increases in the high-cholesterol group over the low-cholesterol group were: for plasma, 206 +/- 0.3 and 256 +/- 0.4 mg/dL, 24.3% (p < 0.001); for RBCs, 93 +/- 0.2 and 106 +/- 0.2mg/dL, 14.0% (p < 0.001); and for RBC membranes, 41 +/- 0.1 and 54 +/- 0.2mg/dL, 31.7% (p < 0.001). The blood O2 diffusion curves were distinctly different between the high- and the low-cholesterol groups (p < 0.05). Blood O2 diffusion, defined by the blood O2 diffusion curves, was inversely proportional to the plasma, RBC, and RBC-membrane cholesterol concentrations. The relative tissue O2 availability, after a circulation period of more than 3 minutes in the diffusion system, showed a decrease of 17.5% (p < 0.05) between the plasma cholesterol groups. In comparing the two plasma cholesterol concentration extremes of less than 200mg/dL (n= 14) and greater than 275 mg/dL (n= 11) after a circulation period of more than 3 minutes in the diffusion system, we found a decrease in relative tissue O2 availability of 35.8% (p < 0.05). CONCLUSIONS: The plasma cholesterol concentration may be an influencing factor in RBC-membrane cholesterol content, which, in turn, may regulate RBC-membrane O2 transport, RBC O2 release, and cellular O2 availability. The implications of this work include the addition of angina pectoris control to the indications for appropriate lipid modification and the development of an in vitro blood stress test to replace patient cardiac stress testing.

Cholesterol↗

Effect of plasma cholesterol on red blood cell oxygen transport.

1. Oxygen (O2) transfer from the blood to tissues is a function of the red blood cell (RBC) O2 saturation (SO2), the plasma O2 content being negligible. Under conditions of increased tissue O2 demand, the SO2 of arterial blood does not change appreciably (97%); however, the SO2 of mixed venous blood, equal to that of the perfused tissues, can go as low as 20%. 2. Tissue O2 availability is limited by the exposure time to a RBC, which decreases under conditions of maximum stress (< 1 s). If the O2 unloading time was to increase significantly, because of a decrease in the RBC diffusion constant or an increase in the RBC membrane thickness, the RBC O2 unloading time would exceed tissue (e.g. cardiac) transit time and O2 transfer would be impaired. 3. Cholesterol constitutes the non-polar, hydrophobic lipid of the enveloping layer of the RBC membrane. As the cholesterol content of the RBC increases, the fluidity of the membrane decreases and the lipid shell stiffens. 4. Early studies demonstrated that high blood cholesterol concentrations were associated with reduced blood O2 transport; in essence, the haemoglobin dissociation curve was shifted to the left. 5. Current investigations have shown that the cholesterol RBC membrane barrier to O2 diffusion delayed O2 entry into the RBC during saturation and delayed O2 release from the RBC during desaturation. In an analysis of 93 patients divided by their cholesterol concentration into five groups, the percentage change in blood O2 diffusion was inversely proportional to the cholesterol concentration. 6. The RBC membrane cholesterol is in equilibrium with the plasma cholesterol concentration. It stands to reason that as the plasma cholesterol increases, the RBC membrane becomes impaired and O2 transport is reduced. 7. The implications of this new perspective on O2 transport include the ability to increase tissue oxygenation by lowering plasma cholesterol.

Animals↗

Radiation dose in interventional fluoroscopic procedures.

Vascular interventional procedures carried out under fluoroscopic guidance often involve high radiation doses. Above certain thresholds, radiation can cause significant damage to the skin including hair loss and severe necrosis. Such damage has been reported by several investigators. Many attempts have been made to quantitate the radiation doses to the skin involved with these procedures, but dosimetry methods are often flawed. To improve the situation better monitoring of radiation doses, fluoroscopist education, and changes in technology and methods are needed.

Europe↗

Establishing a quality control program for an automated dosimetry system.

Automatic dosimetry systems can provide instantaneous dose and dose-rate information during fluoroscopic procedures as well as long-term records of patient doses. For this information to be useful, it is necessary that the accuracy of such systems be maintained through a rigorous quality control program. Daily and weekly quality control checks were performed on a PEMNET automated dosimetry system to determine its stability and the value of such tests in a quality control program. Weekly tests included monitoring the accuracy of the measured doses under a variety of conditions. The results of the tests indicate possible improvements in test methodology and real and potential sources of system failure and provide a statistical basis for setting quality control limits for future system monitoring.

Biophysical Phenomena↗

The potential for radiation-induced skin damage in interventional neuroradiological procedures: a review of 522 cases using automated dosimetry.

The Food and Drug Administration (FDA) has recommended the monitoring of radiation skin dose to patients during procedures having the potential for radiation damage. Radiologists need information about typical radiation doses during interventional procedures. The skin doses to patients during 522 interventional neuroradiological procedures have been monitored using an automated dosimetry system. Estimated entrance skin doses (ESD) were binned into 0.5 Gy increments and compared to FDA recommended thresholds for inclusion in the patient record. Percentages of procedures exceeding the above mentioned thresholds are presented. In addition, the percentage of dose in each view and the percentage of dose in fluoroscopic and digital angiographic modes are shown. Six percent of embolization procedures and one percent of cerebral angiograms are estimated to have potential for main erythema (ESD>6 Gy). All types of procedures have potential for temporary erythema and exceed the threshold for inclusion in the patient record (ESD> 1 Gy) at the 95% percentile. The types of procedures with most potential for skin damage also have significant percentages of dose in the digital angiographic mode. Thus, monitoring fluoroscopic time alone underestimates the potential for skin injury. On the other hand, combining the doses in the posterior-anterior and lateral views, tends to overestimate the potential for radiation injury.

Biophysical Phenomena↗

Decreased blood oxygen diffusion in hypercholesterolemia.

BACKGROUND: Improvement of angina pectoris symptoms after cholesterol lowering has raised questions as to the underlying mechanisms. METHODS: Rabbit experiment: We compared arterial blood samples from New Zealand White cholesterol-supplemented rabbits (n = 6) with nonsupplemented rabbit samples (n = 4) in a closed-loop circulation diffusion system. The pH and partial pressures of oxygen (pO2) and carbon dioxide (pCO2) were measured continuously. The samples were first oxygen (O2) saturated (pO2, 160 mm Hg; pCO2, 4 mm Hg) and then desaturated in 100% nitrogen. Cholesterol levels were determined in whole blood, plasma (P Chol), red blood cells (RBCs), and RBC membranes. Human experiment: We exposed quadruple desaturated venous blood samples (n = 4) with P Chol levels of 87 to 400 mg/dL in a gas exchanger to capillary gas conditions (pO2, 23 mm Hg; pCO2, 46 mm Hg). After 15 minutes we performed blood gas analyses and compared our results to baseline values. RESULTS: In the rabbit experiment the cholesterol-supplemented group as compared to the control group showed higher plasma pO2 levels during the saturation phase and lower plasma pO2 levels during the desaturation phase. It also had a markedly increased RBC membrane cholesterol content: 121 +/- 3 (standard error of the mean [SEM]) mg/dL versus 22 +/- 1.7 mg/dL in the control group (P < .05). This barrier to RBC membrane O2 diffusion caused delayed O2 entry into the RBCs during saturation, with a higher plasma pO2, and delayed O2 release from the RBCs during desaturation, with a lower plasma pO2. In the human experiment the P Chol level was inversely correlated with the percentage change of O2 content in milliliters of O2 per deciliter of blood (P < .05). CONCLUSIONS: Increased RBC membrane cholesterol in hypercholesterolemia appears to decrease the transmembrane O2 diffusion rate.

Animals↗

Protecting the immunocompromised patient: the role of the hospital clinical engineer.

While the discipline of clinical engineering has long been limited to the area of medical equipment management, few areas in hospital engineering practice so closely meet the literal definition of "clinical" engineering as the care of the immunocompromised patient. Although ventilation has been the domain of the plant maintenance department, the increasing numbers of clinical engineers being given responsibility for plant functions, as well as the critical nature of the topic, make the care of the bone marrow transplant (BMT) patient an appropriate area of clinical engineering practice. Further, as clinical engineering branches out of the equipment management area, the clinical engineer can be truly termed the "hospital engineer".

Air Microbiology↗