PubMed Health⌕ Search

Biomedical subjects

T M Cook

Publications and source records attributed to T M Cook.

At least 55 records · Page 3Linked to original sources

Randomized crossover comparison of the proseal with the classic laryngeal mask airway in unparalysed anaesthetized patients.

BACKGROUND: The ProSeal is a wire-reinforced laryngeal mask airway with an additional drain tube that leads to the distal tip of the laryngeal cuff. The design should improve the seal with the larynx. METHODS: The ProSeal and classic laryngeal mask airways were compared in 180 patients in a randomized crossover study. Patients were anaesthetized without neuromuscular blocking drugs. RESULTS: The ProSeal took more time and more attempts to insert successfully than the classic laryngeal mask airway. Insertion was successful on the first attempt in 81% of cases with the ProSeal and 90% with the classic laryngeal mask airway. The ProSeal required more air to achieve an intracuff pressure of 60 cm H2O (6 ml more for size 4 and 12 ml more for size 5). Laryngeal seal pressure was better with the ProSeal than the classic laryngeal mask airway. Median seal pressure was 29 cm H2O with the ProSeal and 18 cm H2O with the classic laryngeal mask airway. Laryngeal seal pressure was greater than 20 cm H2O in 87% of patients with the ProSeal and 41% with the classic laryngeal mask airway. Laryngeal seal pressure was greater than 40 cm H2O in 21% of patients with the ProSeal and in none of the patients with the classic laryngeal mask. Once placed, the ProSeal remained a stable and effective airway. Gastric tube insertion through the drain tube was attempted in 147 cases and was successful in 135 (92%). CONCLUSION: The ProSeal is more difficult to insert than the classic laryngeal mask airway but allows positive pressure ventilation more reliably than the classic laryngeal mask airway.

Adolescent↗

The effect of overhead drilling position on shoulder moment and electromyography.

The effect of overhead drilling tasks on electromyographic (EMG) activity and shoulder joint moment was examined in this study. Twenty subjects simulated an overhead drilling task using a close, middle and far reach position while standing on either a lower or a higher step of a stepladder. Root mean square amplitude (AMP) of EMG activity from the dominant side anterior deltoid, biceps brachii and triceps brachii muscles was used to determine muscular load. Digital video was used to determine shoulder joint moment using 2-dimensional static link segment modelling in the sagittal plane. The results demonstrated that, compared to the far reach position, using the close reach position significantly decreased anterior deltoid AMP and biceps brachii AMP and moment, but increased triceps brachii AMP. Compared to the lower step, using the higher step significantly decreased anterior deltoid AMP and triceps AMP and moment, while increasing biceps AMP in the close position. There was no significant change noted in EMG median frequency indicating that fatigue was minimized. Moment increased monotonically with AMP. The findings indicated that workers performing overhead tasks should work close to their body in order to minimize shoulder forces. The implications of this recommendation are discussed.

Adult↗

Rapid sequence induction: a national survey of practice.

We performed a national postal survey exploring anaesthetists' practice in rapid sequence induction. All respondents used pre-oxygenation, although the technique employed, and its reliability, varied. Thiopental and succinylcholine, given after waiting for signs of loss of consciousness, were the most widely used drugs for rapid sequence induction. Propofol and rocuronium were used by more than a third of respondents, and most respondents (75%) also routinely administered an opioid. Cricoid pressure was used universally but the practice of its application varied widely. The commonest aids used if intubation was difficult were the gum elastic bougie, the long laryngoscope blade and the laryngeal mask. After failed intubation, approximately half of respondents would maintain the supine position. Failure to intubate at rapid sequence intubation had been seen by 45% of respondents but harm was uncommon. In contrast, 28% had seen regurgitation, which frequently led to considerable harm and to three deaths. In spite of this, practice of a failed intubation drill was uncommon (15%) and anaesthetic assistants were rarely known to practice application of cricoid pressure. Consultants were less likely than trainees to use rocuronium as a muscle relaxant, and more likely to choose morphine if administering an opioid. They were less likely to practice a failed intubation drill. Other aspects of practice varied little between grades. This survey suggests that many anaesthetists do not follow best practice when performing a rapid sequence induction.

Anesthesia, General↗

An evaluation of the Airway Management Device.

We have evaluated the Airway Management Device (AMD) in 105 anaesthetised patients. We were successful in establishing a clear airway on the first attempt on 69 occasions and unable to establish a patent airway at all in 10 patients. Airway obstruction requiring removal of the device occurred during maintenance of anaesthesia in a further two cases and during emergence in three. Loss of the airway during anaesthesia occurred in eight of 95 patients and could be reversed by manipulation of the airway in six cases. Overall, a mean of 0.56 manipulations per patient were required to establish an airway and a further 0.42 per patient were required during maintenance of anaesthesia. In the 95 patients in whom an airway was established, assisted ventilation was satisfactory in 93, with a leak pressure above 20 cmH2O in 65. Intracuff pressure was measured in 12 cases and was above 100 cmH2O in eight. Minor complications occurred in 12 patients. Blood was visible on removal of the device in six cases.

Adolescent↗

POGO score.

Explore the source record for details and available documents.

Glottis↗

Combined spinal-epidural techniques.

The combined spinal-epidural technique has been used increasingly over the last decade. Combined spinal-epidural may achieve rapid onset, profound regional blockade with the facility to modify or prolong the block. A variety of techniques and devices have been proposed. The technique cannot be considered simply as an isolated spinal block followed by an isolated epidural block as combining the techniques may alter each block. This review concentrates on technical and procedural aspects of combined spinal-epidural. Needle-through-needle, separate-needle and combined-needle techniques are described and modifications discussed. Failure rates and causes are reviewed. The problems of performing a spinal block before epidural blockade (potential for unrecognised placement of an epidural catheter, inability to detect paraesthesia during epidural placement, difficulty in testing the epidural, delay in positioning the patient) are described and evaluated. Problems of performing spinal block after epidural blockade (risk of catheter or spinal needle damage) are considered. Mechanisms of modification of spinal blockade by subsequent epidural drug administration are discussed. The review considers choice of technique, needle type, patient positioning and paramedian vs. midline approach. Finally, complications associated with combined spinal-epidural are reviewed.

Anesthesia, Epidural↗

A new practical classification of laryngeal view.

A new practical classification of laryngeal view at laryngoscopy is presented and evaluated. The best laryngeal view obtained with or without anterior laryngeal pressure is recorded. The laryngeal view is easy (E) when the laryngeal inlet is visible. The view is restricted (R) when the posterior glottic structures (posterior commissure or arytenoids) are visible or the epiglottis is visible and can be lifted; this includes some grade 2 and some grade 3 views as classified by Cormack and Lehane. A difficult (D) view is present when the epiglottis cannot be lifted or when no laryngeal structures are visible. Five hundred patients were studied. Laryngoscopy, with the patient anaesthetised and paralysed, was performed with a Macintosh laryngoscope. If the vocal cords were not visible, a gum elastic bougie was used to aid intubation. Other aids were used only if this did not allow intubation. Each laryngeal view was graded according to the new classification and that of Cormack and Lehane. Intubation was timed and the equipment needed to facilitate intubation was recorded. The new classification stratified increasing difficulty with intubation (time for intubation longer and increasingly complex methods needed) better than the Cormack and Lehane classification. The new classification is as sensitive and more specific than the Cormack and Lehane classification in predicting difficult intubation. It is also more sensitive and more specific in predicting easy intubation.

Adolescent↗

Patient-controlled intranasal diamorphine for postoperative pain: an acceptability study.

A patient acceptability study was conducted using patient-controlled intranasal diamorphine. Patients undergoing nonemergency orthopaedic or gynaecological surgery self-administered intranasal diamorphine for 24 h postoperatively. Pain, pain relief, sedation, respiratory rate, nausea and vomiting were assessed regularly. After 24 h, patients and their attending nurses completed a questionnaire assessing satisfaction and practical aspects of the technique. Satisfaction was reported as good or complete by 69% of patients and 69% of nurses. Pain relief was assessed as better than expected by 45% of patients and better than normal by 50% of nurses. Seventy-nine per cent of patients would be pleased to use patient-controlled intranasal diamorphine again and 89% of nurses would be happy for their patients to use it again. Sedation was uncommon and mild and there were no episodes of significant respiratory depression. Fifty-three per cent of patients reported no nausea and 74% did not vomit at any stage. There were seven withdrawals, four due to problems with the device and three due to therapeutic problems. The nasal spray may need modification to improve reliability. However, we found patient-controlled intranasal analgesia an effective technique, which was well tolerated by patients and nurses and was without unpleasant side-effects. Further work to determine how it performs compared with intramuscular or intravenous analgesia is now needed.

Administration, Intranasal↗

Cricoid pressure: which hand?

We studied 20 anaesthetic assistants applying simulated cricoid pressure with the left or right hand in random order. Simulated cricoid pressure was continued for up to 5 min with one hand and then, after resting, with the other hand. Applied pressure was measured at intervals and the subjects were blind to the results. Nineteen assistants were right-handed and all routinely applied cricoid pressure with their right hand. Mean (SD) force applied during simulated 'awake' cricoid pressure was 13.8 (5.7) N with either left or right hand, and during 'anaesthetised' cricoid pressure it was initially 25.1 (8.2) N and 24.7 (8.8) N with left or right hand, respectively. Mean force was maintained above 20 N and below 30 N throughout the study period with either hand. Force applied with the left hand was significantly lower than with the right hand but the difference was clinically insignificant (0.4 N). Inadequate or excessive force was more frequently associated with use of the left hand (p < 0.0001). Cricoid pressure was released before 5 min in three cases, two left-handed and one right-handed. Our results demonstrate that anaesthetic assistants apply a lower force than is classically taught and are able to maintain the force with either hand for a sustained period. Application with the left hand is justified where clinically indicated but may have a lower margin for error than when applied with the right hand.

Anesthesia, General↗

The use of participatory action research and ergonomics in the prevention of work-related musculoskeletal disorders in the newspaper industry.

The newspaper industry is one of many in which employees are reported to be at risk for work-related musculoskeletal disorders of the upper extremities and low back. The purpose of this 18-month demonstration project was to assess the usefulness of a participatory ergonomics process as a strategy to reduce the risk factors associated with musculoskeletal disorders at a metropolitan newspaper company. The company involved had 455 employees and a daily circulation of 75,200. Employees from both office and production areas participated. The participatory action research approach utilized required investigators to work collaboratively with the study population. Using a five-step continuous improvement process, the ergonomics committee identified and evaluated jobs having ergonomic risk factors. This was followed by the development, implementation, and evaluations of interventions aimed at reducing risk factor exposure. The committee's productivity and participant feedback were used as measures of the committee's effectiveness. During the project period, interventions were implemented in 11 of 12 targeted departments. Participant ratings of effectiveness for different aspects of the ergonomics process were generally favorable. The mean and median cost for ergonomic interventions were $376 and $25, respectively. This project demonstrated that participatory action research could be used to develop and implement ergonomic solutions that reduce the risk factors associated with work-related musculoskeletal disorders.

Adult↗

Alterations in shoulder kinematics and associated muscle activity in people with symptoms of shoulder impingement.

BACKGROUND AND PURPOSE: Treatment of patients with impingement symptoms commonly includes exercises intended to restore "normal" movement patterns. Evidence that indicates the existence of abnormal patterns in people with shoulder pain is limited. The purpose of this investigation was to analyze glenohumeral and scapulothoracic kinematics and associated scapulothoracic muscle activity in a group of subjects with symptoms of shoulder impingement relative to a group of subjects without symptoms of shoulder impingement matched for occupational exposure to overhead work. SUBJECTS: Fifty-two subjects were recruited from a population of construction workers with routine exposure to overhead work. METHODS: Surface electromyographic data were collected from the upper and lower parts of the trapezius muscle and from the serratus anterior muscle. Electromagnetic sensors simultaneously tracked 3-dimensional motion of the trunk, scapula, and humerus during humeral elevation in the scapular plane in 3 handheld load conditions: (1) no load, (2) 2. 3-kg load, and (3) 4.6-kg load. An analysis of variance model was used to test for group and load effects for 3 phases of motion (31(-60(, 61(-90(, and 91(-120(). RESULTS: Relative to the group without impingement, the group with impingement showed decreased scapular upward rotation at the end of the first of the 3 phases of interest, increased anterior tipping at the end of the third phase of interest, and increased scapular medial rotation under the load conditions. At the same time, upper and lower trapezius muscle electromyographic activity increased in the group with impingement as compared with the group without impingement in the final 2 phases, although the upper trapezius muscle changes were apparent only during the 4.6-kg load condition. The serratus anterior muscle demonstrated decreased activity in the group with impingement across all loads and phases. CONCLUSION AND DISCUSSION: Scapular tipping (rotation about a medial to lateral axis) and serratus anterior muscle function are important to consider in the rehabilitation of patients with symptoms of shoulder impingement related to occupational exposure to overhead work. [Ludewig PM, Cook TM. Alterations in shoulder kinematics and associated muscle activity in people with symptoms of shoulder impingement.

Adult↗

Electromyographic effects of ergonomic modifications in selected meatpacking tasks.

This project evaluated the feasibility of a new method of collection of electromyographic (EMG) data during working conditions in industry, and quantified the effects of specific job modifications on the EMG activity of selected upper extremity muscle groups. Average root mean square (RMS) surface EMG activity, calibrated to force equivalent units, was collected on 20 workers from three pork processing tasks before and after ergonomic modifications to their tasks. Significant reductions in muscle effort were detected in the biceps and/or wrist and finger flexors after modification for two of the three tasks. This EMG measurement technique can be used to objectively validate reduced muscle effort with ergonomic modifications.

Adult↗

Combined spinal epidural anaesthesia: a new technique.

A new technique is described for delivering combined spinal epidural anaesthesia. The disadvantages of the needle-through-needle technique and the two-needle techniques are discussed. The new technique is a modification of the two-needle technique. The spinal needle is introduced and once cerebrospinal fluid is seen at the hub of the needle, the stylet is replaced. The epidural space is then identified and the epidural catheter placed. The spinal needle obturator is then removed and intrathecal injection performed. This technique avoids problems associated with placing an epidural catheter after an intrathecal injection and the potential problem of placing a spinal needle when an epidural catheter has already been placed. This technique requires further evaluation.

Journal Article↗