Accuracy of T1 measurement in dynamic contrast-enhanced breast MRI using two- and three-dimensional variable flip angle fast low-angle shot.

In vivo T1 measurements, used to monitor the uptake of contrast agent by tissues, are typically performed as a first step in implementing compartmental analysis of contrast-enhanced breast magnetic resonance imaging (MRI) data. We have extended previously described methodology for in vivo T1 measurement (using a variable flip-angle gradient-recalled echo technique) to two-dimensional (2D), fast low-angle shot (FLASH). This approach requires computational modeling of slice-selective radiofrequency (RF) excitation to correct for nonrectangular slice profiles. The accuracy with which breast tissue T1 values can be measured by this approach is examined: T1 measurements from phantom and in vivo image data acquired with 2D and 3D FLASH imaging sequences are presented. Significant sources of error due to imaging pulse sequence quality and RF transmit field nonuniformity in the breast coil device that will have detrimental consequences for compartmental analysis are identified. Rigorous quality assurance programs with calibrated phantoms are thus recommended, to verify the accuracy with which T1 measurements are obtained.

Breast↗

Sources of artifact and systematic error in quantitative snapshot of FLASH imaging and methods for their elimination.

Snapshot FLASH preceded by a preparation sequence is used to measure NMR parameters. Some preparation information is lost during snapshot FLASH acquisition as the magnetization evolves towards the steady state. This problem is often addressed by assuming that image intensity is proportional to the central k-space line, which may be sampled immediately after preparation using a centric-reordered scheme. Although some limitations of this assumption have been discussed, they are often ignored in parameter measurement. In this study, magnetization evolution effects in snapshot FLASH were investigated by computer simulation and phantom experiments in the context of T2 measurement. It was found that the standard analysis may lead to significant error in parameter measurement. Some improvement may be obtained using a more sophisticated analysis to take account of magnetization evolution. However, at the expense of a 50% reduction in signal intensity, accurate values may be obtained by a novel method that uses crusher gradients to eliminate evolved magnetization.

Artifacts↗

A novel fast split-echo multi-shot diffusion-weighted MRI method using navigator echoes.

Difficulties in obtaining diffusion-weighted images of acceptable quality using conventional hardware and in a reasonable time have hindered the clinical application of diffusion-weighted magnetic resonance imaging (DWI). Diffusion-weighted fast spin-echo (FSE) sequences offer the possibility of fast DWI on standard hardware without the susceptibility problems associated with echoplanar imaging. However, motion in the presence of diffusion-sensitizing gradients can prevent fulfilment of the Meiboom Gill phase condition, leading to destructive interference between echo components and consequent signal losses. A recently proposed single-shot FSE sequence employed split-echo acquisition to address this problem. However, in a segmented FSE sequence, phase errors differ between successive echo trains, causing "ghosting" in the diffusion-weighted images that are not eliminated by split-echo acquistion alone. A DWI technique is presented that combines split-echo acquisition with navigator echo phase correction in a segmented FSE sequence. It is shown to be suitable for diffusion measurements in vivo using standard hardware.

Brain↗

Determination of normal regional left ventricular function from cine-MR images using a semi-automated edge detection method.

A semi-automated edge detection method for the delineation of the endo- and epicardial borders of the left ventricle from cine MR images has been developed. The feasibility of this was demonstrated by processing end diastolic and end systolic ECG-gated images of four short axis images in 10 healthy subjects. The first derivative method combined with a 2D weighted polynomial fitting procedure was used to determine the endo- and epicardial borders, which then allowed determination of the wall motion, wall thickening, and ejection fraction, of the left ventricle. The results show that the end-systolic radial wall motion varies from (32+/-8)% to (76+/-12)%, and wall thickening from (0.60+/-0.46) cm to (1.26+/-0.50) cm. An average ejection fraction of (69+/-6)% was found which agrees well with literature values. The method described, for the delineation of the borders, reduces considerably the long and tedious operator time inherent in manual measurement and greatly increases the reproducibility of the measurements.

Adult↗

Assessment of the sinus lift operation by magnetic resonance imaging.

Sinus lift operations are done to increase bone thickness before placement of osseointegrated implants in areas of the maxilla where there is insufficient bone between the lower border of the maxillary sinus mucosa and the oral mucoperiosteum. Full sectional information should be available to the surgeon before the sinus lift operation so that the outcome can be predicted, and to allow for assessment of the volume of bone graft required. It is also useful to assess the success of the procedure before placement of the implant, and to choose the implant length and orientation required for maximum stability. We describe the use of a 0.2 tesla magnetic resonance imaging (MRI) scanner to image a patient before and after sinus lift. MRI gave full sectional information of the bone on both occasions without using ionizing radiation. The quality of the images was good, and should be considered as an alternative to the accepted gold standard of computed tomography (CT), which exposes the patient to a high dose of radiation.

Bone Transplantation↗

Magnetic resonance imaging: a useful tool for evaluation of bone prior to implant surgery.

OBJECTIVE: To illustrate the potential for use of magnetic resonance imaging (MRI) to gain full sectional information before placement of osseo-integrated dental implants, with no patient exposure to ionising radiation. MATERIALS AND METHODS: Four typical cases are illustrated, the patients being imaged in a one tesla MRI scanner. The setting up of the sequences is explained, along with the use of an imaging/surgical template with gadolinium markers. RESULTS: MRI clearly shows full sectional detail of available bone for safe implant placement, and allows the delineation of cortical and cancellous bone to attain maximum implant length and stability. Vital structures and the floor of the maxillary sinus are clearly shown. CONCLUSIONS: MRI allows the surgeon to assess cases for suitability to place dental implants with confidence. The ability to scan directly at any desired plane, with no reformatting, and to relate this information to a surgical template gives predictable surgery. MRI is a sectional imaging modality giving information about the 3-dimensional relationship of the vital structures, without using ionising radiation. It therefore deserves consideration as an alternative to computed tomography. However, further work is indicated to investigate the relative technical merits of the two imaging modalities.

Adult↗

Comparison of four magnetization preparation schemes to improve blood-wall contrast in cine short-axis cardiac imaging.

Improvements in short-axis blood-myocardium contrast in the heart with the use of four magnetization preparation schemes applied before the imaging sequence are demonstrated. Gradient-echo cine cardiac images are acquired and compared at 0.95 T incorporating T2, T1rho, magnetization transfer, and double inversion (black blood) preparations in a series of volunteer studies over the first 550 ms of the cardiac cycle. T2 and T1rho preparations exhibit improvements of 100% and above in image contrast. Magnetization transfer preparation exhibits improvements of 50% in image contrast, whereas an initial improvement (50%) followed by a large loss in contrast is observed using the black blood preparation. Improvements in contrast are dependent on tissue relaxation parameters and therefore are suitable for studies involving patients exhibiting poor in-flow enhancement of blood caused by poor heart function.

Computer Simulation↗

Split-and-merge segmentation of magnetic resonance medical images: performance evaluation and extension to three dimensions.

Intensity- or edge-based methods of segmentation are often insufficiently robust to be applied to images containing complex anatomical objects, such as those seen in high-resolution magnetic resonance imaging systems. Split-and-merge techniques attempt to overcome these difficulties by using homogeneity measures. Simple modifications to the basic 2D split-and-merge method, based on the principles of simulated annealing and controlled boundary elimination, are developed and discussed. Simulated annealing reduced the number of regions by 22% with a further reduction of 21% achieved through boundary elimination. Smoother regional boundaries are also produced. These methods are extended to true 3D and quantitatively compared with their 2D counterparts. The main advantage of 3D methods is that they produce segmented volumes by directly preserving the connectivity between slices, whereas in 2D, segments have to be grouped together in a post-split-and-merge process. Finally, the properties of the 3D approach are demonstrated by the automatic quantitation of brain ventricle volume, producing estimates to within 7% of validated manual methods.

Algorithms↗

Estimating spatial resolution of in vivo MR images using spatial modulation of magnetization.

Spatial Modulation of Magnetization is shown to provide a means of estimating perceived spatial resolution directly in vivo. On the first magnetic resonance system tested, resolution in conventional spin echo images was found to be stability limited in the phase encoding direction and voxel limited (via the Nyquist sampling theorem) in the frequency encoding direction both in vitro and in vivo. As the voxel size approaches half the stripe separation, fringes of resolved and unresolved stripes are formed across the image. This phenomenon is explained and described mathematically. On a second magnetic resonance scanner, resolution in the phase encoding direction of fast spin echo images with centrically ordered phase encoding is shown to be voxel limited in substances with long T2, with poorer resolution in substances with short T2. Resolution in fast spin echo images with linearly ordered phase encoding was shown to be voxel limited in the phase encoding direction.

Artifacts↗

Low-field magnetic resonance imaging for implant dentistry.

OBJECTIVE: To evaluate the use of a low-field magnetic resonance scanner for assessment of available bone for placement of osseo-integrated dental implants. METHODS: Eleven Patients were examined to assess suitability for implant placement using a 0.2 tesla 'open' scanner. Imaging/surgical templates were constructed, with gadolinium markers to allow accurate location of the implant sites. RESULTS: In all cases, localisation of potential implant sites was easily made and full information in all three planes readily available. Artefacts were few and localised, (noted on one site in one case only). Vital structures (nerves and vessels), and the variable geometry of the floor of the maxillary sinus were clearly seen, and cortical bone delineated from cancellous. The appearance of soft tissues in the scan allowed the surgeon to assess the final profile of the patient. CONCLUSION: Low-field magnetic resonance imaging has definite potential for pre-implant assessment. Full sectional information is readily available at any desired plane with no need for reformatting. The information for accurate and safe implant placement is clear. The technique uses no ionising radiation. Further work is needed to evaluate spatial distortion caused by magnetic susceptibility effects at air/tissue interfaces, but our calculations indicate that at low field, using an appropriate protocol, the effect will not be substantial.

Alveolar Process↗

Temporomandibular joint MRI: a 2-D gradient-echo technique.

Magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ) has been most commonly performed using spin-echo sequences. Gradient-echo sequences have previously been investigated in the context of 3-D and 'dynamic' (pseudo-kinematic) imaging. We have used gradient-echo to improve image quality in static studies with rapid acquisition, high spatial resolution (512 x 512 matrix) and excellent contrast resolution. Using pragmatic methods and a non-randomized study group we have demonstrated a definite advantage to image quality, and thus diagnostic confidence, from the use of a gradient-echo high spatial resolution sequence incorporating split acquisition open mouth views.

Adolescent↗

A bandwidth indicator for magnetic resonance imagers.

Signal-to-noise ratios in magnetic resonance imaging are crucial in determining image quality, and dependent on a number of factors, one being the signal bandwidth per pixel. Not all manufacturers clearly state the bandwidth per pixel used for all sequences. A small battery-powered portable device is described which produces bright sharp lines on the magnetic resonance image at 10 kHz intervals in the frequency encoding direction. The bandwidth per pixel can then easily be calculated using electronic distance callipers, provided the image matrix and field of view are known. The device is expected to be especially of value when acceptance testing on poorly documented imaging systems.

Biophysical Phenomena↗

MRI developments in perspective.

Following Paul Lauterbur's seminal 1973 paper in Nature, considerable work was needed to overcome a number of physical, engineering and technical problems before the new technique of magnetic resonance imaging (MRI) could be applied clinically. Much of that pioneering work was done in the UK. Since the first head and whole-body images were obtained in the late 1970s, MRI has become a widely used clinical imaging modality capable of yielding tomographic images of excellent spatial resolution and tissue contrast. This review outlines the historical development of MRI in the context both of the technical problems which had to be overcome, and of the clinical uses of MRI. Current areas of research, such as the use of MRI to map brain function, the measurement of physiological parameters such as tissue perfusion, and the use of open-access real-time MRI to guide interventional procedures, are briefly discussed.

Equipment Design↗

The influence of stimulated echoes on contrast in fast spin-echo imaging.

Tissue contrast obtained using fast spin-echo (FSE) and conventional spin-echo (SE) sequences is not identical and a number of mechanisms are thought to contribute to these contrast differences. The effect of stimulated echoes has previously been apparently ruled out as a contributing mechanism. Signal-to-noise ratios of single-slice matched FSE and conventional SE sequences were compared in aqueous solutions of CuSO4, Cr2(SO4)3 and MnSO4 with various T1 and T2 values. Enhancement of the FSE signal was observed in short T2 solutions and the effect was greater in samples where the T1 to T2 ratio was high. Reducing the refocusing pulse flip angle to increase the contribution from stimulated echoes also resulted in slightly increased enhancement. Experimental results were verified by computer simulations. Our results show that stimulated echoes do contribute to the contrast differences between FSE and conventional SE images and may be significant in the imaging of brain hemorrhage.

Computer Simulation↗

Choice of contrast enhancement index for dynamic magnetic resonance mammography.

Indices are often used in dynamic MRI of the breast to quantitate signal enhancement within suspicious lesions. Two indices are commonly used: one calculates the difference in pre- and postcontrast signal intensity, normalised to a base-line signal intensity such as that of fat (which does not enhance) whilst the other calculates the ratio of pre- to postcontrast signal intensity. The results of a computational simulation are presented which demonstrate the superiority of the normalised signal difference index, based on the criterion that the best index is that which is least influenced by initial tissue T1. This hypothesis was tested by comparing the two indices in a group of patients with clinical or mammographic suspicion of recurrent breast carcinoma. Of 37 patient examinations using Gadolinium enhanced MRI of the breast, 11 patients showed 13 lesions with some degree of enhancement, which were subsequently diagnosed histologically as either benign or malignant. The normalised signal difference index showed no overlap between the benign and malignant groups, whereas some overlap was observed with the signal ratio index. The clinical findings are therefore consistent with the results of the computational simulation.

Adult↗

A variable threshold edge-detector for improved quantitation of gated tomographic imaging of the left ventricular blood pool.

The accurate measurement of left ventricular volume from tomographic MUGA studies is difficult due to the limited resolving power of the gamma camera, which causes errors in the detection of the correct ventricular boundaries. Therefore, the use of fixed threshold or second-derivative edge-detectors results in overestimates at small volumes. A variable threshold edge-detection technique was developed to overcome this. Computer-simulated short-axis slices through the heart over a range of left ventricular dimensions were convolved by the Point Spread Response Function of the system to model the acquired image. The maximum pixel value and the threshold value required to detect the true ventricular edge from each simulation were then combined into a look-up table for the calculation of the required threshold value. As the dimension of the ventricle decreased, the threshold value chosen to detect the ventricular edge increased. Left ventricular volumes and ejection fraction measurements were calculated for seven patients using cine-MRI as the gold-standard technique for validation of the proposed method. The single photon emission tomographic studies were analysed using both the standard second-derivative edge-detection software and the proposed variable threshold technique. The variable threshold technique was shown to increase significantly the accuracy of ventricular volume measurements and ejection fraction calculations. The average error in the measurement of volumes was reduced from 41.4 +/- 45.1% to 18.5 +/- 14.6% and the accuracy of ejection fraction measurement was increased from 29.7 +/- 4.6% to 11.3 +/- 6.9%.

Algorithms↗

Measurement of spin-lattice relaxation times with FLASH for dynamic MRI of the breast.

Using a variable flip angle gradient refocused imaging technique, dynamic quantitative T1 relaxation maps acquired before and after the administration of a gadolinium contrast bolus enable the concentration-time curve of the paramagnetic agent in breast tissue to be calculated. This imaging technique has the aim of improving the diagnostic accuracy of MR mammography. Measurements with phantoms of calibrated T1 values have been carried out to investigate the accuracy of the method, with particular reference to errors caused by incomplete spoiling of residual transverse magnetization and inaccurate radio frequency (RF) flip-angle settings. A clinical example is presented. The method has potential use for any patient study which necessitates rapid quantitation of changing in vivo T1 values as a result of contrast agent injection.

Breast Neoplasms↗