Application of the principle of optical phase-contrast microscopy to velocity phase-encoded MRI of blood flow in the aorta.

A new method of presenting magnetic resonance phase information is described and an example of its application given in the context of velocity phase-encoded MRI of blood flow in the aorta. The method takes as its starting point Zernike's technique of phase contrast microscopy. It exploits the parallel between the transform plane in Fourier optics and kappa-space in MRI. In the example described two datasets are acquired, one with and the other without velocity encoding, as in conventional phase-encoded velocity imaging. A dataset is formed which is corrected for unwanted phase variations caused by static field inhomogeneity. The method then effectively combines phase and magnitude information into a single image. The technique is complementary to existing methods of displaying phase information.

Aorta↗

Dynamic magnetic resonance mammography of both breasts following local excision and radiotherapy for breast carcinoma.

The purpose of this study was to evaluate a dynamic gadolinium-diethylene-triaminepentacetate (Gd-DTPA) enhanced magnetic resonance mammography (MRM) protocol, incorporating image subtraction and using a dedicated double breast coil, in patients with treated breast cancer. 36 patients who had undergone breast conserving surgery and radiotherapy, with clinical or mammographic suspicion of locally recurrent breast carcinoma, were examined. 3D rapid volume imaging of both breasts was performed before and repeated three times, at 1, 2 and 3 min, following Gd-DTPA enhancement. Image subtraction allowed identification of enhancing lesions and quantitative analysis of these was performed. Five patients had six lesions demonstrating rapid enhancement in the first minute, all of which were histologically confirmed recurrent or second primary tumours. Slower enhancement was seen in six benign lesions and diffuse enhancement was seen in one patient within 6 months of treatment. The dynamic protocol used allowed sufficient temporal resolution for distinguishing malignant from benign lesions at the site of previous surgery and ensured that both breasts were imaged in their entirety, thus enabling the diagnosis of multifocal and second primary tumours.

Adult↗

Pre-surgical dental implant assessment by magnetic resonance imaging.

The use of magnetic resonance imaging (MRI) for pre-surgical implant assessment of available bone in the maxilla and mandible is described. An acrylic surgical template with suitable MRI reference markers allows potential implant sites, as chosen on the MR images, to be accurately identified at surgery. MRI is a tomographic modality capable of giving accurate information on the three-dimensional relationships of all the relevant anatomic structures. Our results show that MRI is reasonably tolerant of artifacts caused by metal pins and amalgam fillings. Unlike computerized tomography (CT) and other x-radiographic techniques, MRI uses no ionizing radiation, and is capable of angulating and offsetting its scan plane at will. Good bone detail is available because cancellous bone yields a strong signal from the marrow fat, while cortical bone and dental enamel are dark. The excellent anatomic detail provided by thin-slice high-resolution MRI allows for assessment of the suitability of sites to receive an implant in terms of bone quality and thickness, and the relative position of the site to important structures such as the inferior dental nerve and nasal sinuses. The MRI technique used is described in detail. The principles underlying image contrast are outlined where appropriate and examples shown. To date, we have used MRI in conjunction with rotational panoramic x-rays (OPG) to plan 26 implants (21 maxillary, 5 mandibular) in 12 patients.

Alveolar Bone Loss↗

Aortic distensibility and stiffness index measured by magnetic resonance imaging in patients with Marfan's syndrome.

OBJECTIVES: To use magnetic resonance imaging to measure the elastic properties of the aorta of adults with Marfan's syndrome and to compare these results with those obtained by echocardiography. PATIENTS AND METHODS: 12 patients with Marfan's syndrome and 12 controls matched for age. Transverse luminal areas of the ascending and descending aorta were measured using electrocardiographic gated magnetic resonance imaging. Echocardiography was used to measure the diameter of the ascending aorta and aortic arch in patients with Marfan's syndrome. Blood pressure was measured during both scans. RESULTS: In diastole, transverse luminal areas of the ascending and descending aorta were significantly greater in patients with Marfan's syndrome when measured by magnetic resonance imaging and corrected for body surface area; P < 0.02 and P < 0.05 respectively. Patients with Marfan's syndrome had a higher stiffness index (112.77 v 5.78, P < 0.05) and a lower distensibility (0.0066 v 0.0105, P < 0.05) than controls. Results produced by MRI and echocardiography were not significantly different. CONCLUSIONS: Magnetic resonance imaging gives good quality reproducible images of the ascending and descending aorta. In patients with Marfan's syndrome, aortic distensibility and stiffness index measured by magnetic resonance imaging were abnormal (but did not always relate directly to the size of the aorta.

Adult↗

Evaluation of tilted, optimized, non-saturating excitation pulses in 3D magnetic resonance angiography of the abdominal aorta and major branches in volunteers.

Ten normotensive volunteers were imaged with FISP-3D (Fast Imaging Steady Precession) pulse sequences (a steady state gradient recalled echo, SS-GRE, technique) without and with modification by tilted, optimized non-saturating excitation (TONE) customized radio frequency (RF) pulses, for evaluation of the abdominal aorta--in particular the renal arteries. Maximum intensity projection (MIP) angiograms were constructed for each sequence in each volunteer; 15 observers "blinded" to sequence type preferred the images generated from the TONE applied sequence. Analysis showed that this preference was significant.

Aorta, Abdominal↗

Cine magnetic resonance imaging of pulsatile cerebrospinal fluid flow using CSPAMM.

Spatial modulation of magnetization (SPAMM) is a well established imaging technique which superimposes a tagging pattern on conventional magnetic resonance (MR) images, allowing movement to be visualized. A modification to the SPAMM technique, called complementary spatial modulation of magnetization (CSPAMM), which improves the contrast of the tagging pattern is explained. The application of CSPAMM to the visualization of pulsatile cerebrospinal fluid flow (CSF) using an 8 frame cardiac-gated cine sequence is described. Various combinations of binomial pulses, up to the fifth order, were investigated to see which produces the optimum tagging pattern in the CSPAMM images. The flip angles of the imaging RF pulses were studied to see which would give equal maximum CSF signal intensity in all the cine images. The optimized cine CSPAMM technique was compared in vivo with SPAMM and CSF motion was found to be more easily visualized in the CSPAMM images.

Cerebrospinal Fluid↗

Technical note: use of a double inversion recovery pulse sequence to image selectively grey or white brain matter.

The design of a double inversion recovery (DIR) sequence, to image selectively grey or white brain matter, is described. Suitable choice of inversion times allows either cerebrospinal fluid (CSF) and white matter to be suppressed, to image the cortex alone, or CSF and grey matter to be suppressed, to image the white matter. The DIR sequence was found to give clear delineation of the cerebral cortex.

Adult↗

A cine-SPAMM sequence for NMR imaging of pulsatile cerebrospinal fluid flow.

The technical difficulties in designing a SPAMM sequence to image pulsatile cerebrospinal fluid (CSF) flow at different phases of the cardiac cycle are described. The criteria used to select the most appropriate order of binomial SPAMM sequence are outlined. Data collection times required to view both cephalad and caudad flow for all R-R intervals were considered. The flip angles of the RF pulses required to produce images with equal CSF intensity throughout the cardiac cycle were investigated in detail.

Cerebrospinal Fluid↗

Fat suppressed magnetic resonance imaging at 0.5 T using binomial radiofrequency pulses.

Fat suppressed MR imaging can be achieved by selectively saturating lipid protons, just before applying a conventional spin-echo rf pulse sequence. The difference in the Larmor frequency between fat and water protons is only 3.5 ppm, so that the frequency response of the suppressing pulse, or pulses, has to be carefully designed. The choice of suitable binomial and modified trains of hard rf pulses was investigated by computer simulation, phantom testing and T1 weighted spin-echo imaging of a normal volunteer's optic nerve at 0.5 T.

Computer Simulation↗

Noise correlation in multicoil receiver systems.

When two or more rf coils are used to receive NMR signals from the same part of the patient, the overall sensitivity of an image formed from some combination of these signals may be degraded if noise voltages in the coils are correlated. Whereas it is straightforward to calculate correlation caused by noise sources in the coils themselves, there is disagreement about noise correlation when that noise arises from thermally driven currents within the body itself. A general analysis based on the principles of reciprocity, superposition, and energy conservation yields an equation for sample-induced noise correlation in terms of circuit impedances. Furthermore, the analysis yields a very simple expression for the total noise correlation (i.e., noise from patient and coil elements) between the coils. This latter expression is applicable to any two-port receiver coil assembly, including single coils with two modes, such as a birdcage coil, and in general, to any two ports of an n-port receiver system.

Artifacts↗

Magnetic resonance imaging of pulsatile cerebrospinal fluid flow by spatial modulation of magnetization.

Various orders of binomial spatial modulation of magnetization sequences up to (1 4 6 4 1) have been tested to find the optimum sequence for clinical application. Stripe width, stripe sharpness and the tolerance of the sequences to radiofrequency non-linearity have been investigated. The (1 3 3 1) sequence was found to be a good compromise between competing design criteria, and its application to viewing pulsatile cerebrospinal fluid motion is described.

Cerebrospinal Fluid↗

Low-field cine magnetic resonance imaging in aortic valve disease.

Cine magnetic resonance imaging (MRI) holds considerable promise as a means of detecting abnormal blood flow patterns with the heart and great vessels. To date, the majority of techniques employed have required moderate to high field strengths. We describe a novel, low-field-strength approach that is technically undemanding and faster than conventional methods, which we have applied to the detection of aortic valve disease. A series of 26 patients with aortic stenosis or aortic regurgitation was compared with 21 normal subjects. All 20 patients with aortic stenosis and 15 of 16 patients with aortic regurgitation were identified. There were four false positives in the aortic stenosis group; all these patients had significant aortic regurgitation. There were no false positives in the aortic regurgitation group. Low-field cine MRI is a practical and useful technique for the detection of aortic valve disease.

Adolescent↗

FADE--a new fast imaging sequence.

A series of rapid, equally spaced rf pulses of constant amplitude produces two distinct components of transverse magnetization. FADE (fast acquisition double echo) is a new Fourier steady-state free precession (SSFP) imaging sequence which images both components separately in each interpulse interval. The first component gives more signal than the second but lacks contrast while the second is strongly T2 weighted.

Fourier Analysis↗

Magnetic resonance image synthesis from an interleaved saturation recovery/inversion recovery sequence.

An interleaved saturation recovery/inversion recovery (SR/IR) pulse sequence allows the sign of the IR signal to be retained even if images are formed from the magnitude of the two-dimensional complex Fourier transforms of the raw data. Synthesis of images by a linear combination of SR and signed IR pixel values has proved a valuable method of relaxation time (T1) contrast manipulation without the need to re-image the slice. Linear combination has also allowed IR images with a wide range of time-to-inversion (TI) values to be synthesized from an SR/IR pair obtained with TI = 200 ms and time-to-recovery (TR) = 1000 ms, thus avoiding the need for computationally intensive calculations based on complicated relaxation equations.

Computer Simulation↗

Magnetic resonance imaging of the orbits using a binocular surface coil.

Sixty subjects, including 12 normal volunteers, have been studied using the Aberdeen 0.08 T magnetic resonance imager. A wide range of pathological conditions, including both ocular and and orbital disease, have been examined using a specialized binocular surface coil. The images produced using this coil are superior to those made with a head coil and have the advantage of demonstrating both eyes simultaneously. Each patient has been studied using a pulse sequence combining alternate saturation-recovery and inversion-recovery pulses. The resultant short time-to-inversion inversion-recovery and saturation-recovery images have been shown to be accurate in demonstrating the normal anatomy of the globe and orbit and for the demonstration of a wide range of disease states.

Abscess↗