PubMed Health⌕ Search

Biomedical subjects

Takehiko Kitamori

Publications and source records attributed to Takehiko Kitamori.

At least 19 recordsLinked to original sources

Development of a microchip-based bioassay system using cultured cells.

We developed a novel bioassay system using a glass microchip and cultured cells. A microchamber for cell culture and microchannels for reactions and detection were fabricated on a Pyrex glass substrate by photolithography and wet etching techniques. Cell culture, chemical and enzymatic reactions, and detection were integrated into the microchip. To keep different temperatures locally in three areas of the microchip, we designed and fabricated a temperature control device. Nitric oxide released from macrophage-like cells stimulated by lipopolysaccharide was successfully monitored with the microchip, the temperature control device, and a thermal lens microscope. The total assay time was reduced from 24 to 4 h, and detection limit of NO was improved from 1 x 10(-6) to 7 x 10(-8) M compared with conventional methods. Moreover, the system could monitor a time course of the release, which is difficult to measure by conventional batch methods. We conclude that this system is promising for a rapid bioassay system with very small consumption of cells.

Animals↗

Surface modification method of microchannels for gas-liquid two-phase flow in microchips.

A capillarity restricted modification method for microchannel surfaces was developed for gas--liquid microchemical operations in microchips. In this method, a microstructure combining shallow and deep microchannels and the principle of capillarity were utilized for chemical modification of a restricted area of a microchannel. A hydrophobic--hydrophilic patterning in microchannels was prepared as an example for guiding gas and liquid flows along the respective microchannels. Validity of the patterning was confirmed by measuring aqueous flow leak pressure from the hydrophilic microchannel to the hydrophobic one. The leak pressure of 7.7-1.1 kPa agreed well with that predicted theoretically from the Young-Laplace equation for the microchannel depth of 8.6-39 microm. In an experiment to demonstrate usefulness and effectiveness of the method, an air bubble was first introduced into the hydrophilic microchannel and purged from the hydrophobic-hydrophilic patterned microchannels. Next, the patterning structure was applied to remove dissolved oxygen by contacting the aqueous flow with a nitrogen flow. The concentration of dissolved oxygen decreased with contact time, and its time course agreed well with numerical simulation. These demonstrations showed that the proposed patterning method can be used in general microfluidic gas-liquid operations.

Biomechanical Phenomena↗

Thermal lens micro optical systems.

This paper describes two types of miniaturized thermal lens optical systems that use optical fibers, SELFOC microlenses and light sources. The first system consists of a compact diode pumped solid-state laser (532 nm) as an excitation light source, a laser diode (635 nm) as a probe light source, an acoustoptic modulator as an excitation light modulator, fiber-based and conventional optics, and a detection system that combines a pinhole, an interference filter, and a photodiode. The second system consists of two laser diodes as the excitation (658 nm) and probe (780 nm) light sources, fiber-based optics, and the same detection system as the first one. The performance of the two systems was evaluated by the limit of detection (LOD) using standard solutions of sunset yellow (SY) and nickel(II) phthalocyaninetetrasulfonic acid tetrasodium salt (NiP). The LODs of the first system for SY and second system for NiP were calculated to be 3.7 x 10(-8) (1.7 x 10(-6) AU) and 7.7 x 10(-9) M (3.4 x10(-6) AU), respectively. These results were consistent with the expected values obtained from photothermal parameters.

Journal Article↗

Optimization of an interface chip for coupling capillary electrophoresis with thermal lens microscopic detection.

This paper presents a capillary-to-microchip connection, which can be used as an interface for coupling capillary electrophoresis (CE) with a thermal lens microscope (TLM). It is difficult to directly apply TLM to samples in a capillary with a curved surface, and such an interface chip at the end of a CE separation column is needed for reliable TLM measurements. The dependence of the TLM signal intensity on the TLM detection point in the interface chip and the dependence of the theoretical plate number of CE separation on the channel dimensions of the interface chip were investigated and optimized with a mixture of 4-dimethylaminoazobenze-4'-sulfonyl (DABSYL)-derivatized amino acids (glycine, alanine, methionine, and proline) as a model sample. By using an optimized interface chip, theoretical plate numbers of DABSYL-glycine, -methionine, -alanine, and -proline were obtained to be 104000, 95000, 104000, and 95000, respectively.

Amino Acids↗

Grazing-exit and micro X-ray fluorescence analyses for chemical microchips.

Grazing-exit x-ray fluorescence (GE-XRF) and micro x-ray fluorescence (micro-XRF) methods were applied to chemical microchips as a detection method. Since an energy-dispersive x-ray detector was used, the simultaneous detection of multiple elements was possible. An analyzing region was especially designed on the microchip so that a sample solution could be dried and concentrated in a suitable area corresponding to the size of the primary x-ray beam. Finally, it was confirmed that both analytical methods could be combined well for use with a microchip. In GE-XRF, the background intensity in the XRF spectrum was reduced at grazing-exit angles. In addition, a good relationship between the x-ray fluorescence intensities and the concentrations of standard solutions that were introduced into the microchip was obtained. This indicates that the GE-XRF method is feasible for trace elemental analysis in chemical microchip systems. In micro-XRF, an attempt was made to concentrate and dry the analyte within a small analyzing region. The preliminary results indicated that the micro-XRF method could be applied for the analysis of microchips.

Journal Article↗

Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection.

A microchip-based enzyme-linked immunosorbent assay (microELISA) system was developed and interferon-gamma was successfully determined. The system was composed of a microchip with a Y-shaped microchannel and a dam structure, polystyrene microbeads, and a thermal lens microscope (TLM). All reactions required for the immunoassay were done in the microchannel by successive introduction of a sample and regents. The enzyme reaction product, in a liquid phase, was detected downstream in the channel using the TLM as substrate solution was injected. The antigen-antibody reaction time was shortened by the microchip integration. The limit of the determination was improved by adopting the enzyme label. Moreover, detection procedures were greatly simplified and required time for the detection was significantly cut. The system has good potential to be developed as a small and automated high throughput analyzer.

Enzyme-Linked Immunosorbent Assay↗

Capillary-assembled microchip for universal integration of various chemical functions onto a single microfluidic device.

A novel concept for assembling various chemical functions onto a single microfluidic device is proposed. The concept, called a capillary-assembled microchip, involves embedding chemically functionalized capillaries into a lattice microchannel network fabricated on poly(dimethylsiloxane) (PDMS). The network has the same channel dimensions as the outer dimensions of the capillaries. In this paper, we focus on square capillaries to be embedded into a PDMS microchannel network having a square cross section. The combination of hard glass square capillary and soft square PDMS channel allows successful fabrication of a microfluidic device without any solution leakage, and which can use diffusion-based two-solution mixing. Two different types of chemically modified capillaries, an ion-sensing capillary and a pH-sensing capillary, are prepared by coating a hydrophobic plasticized poly(vinyl chloride) membrane and a hydrophilic poly(ethyleneglycol) membrane containing functional molecules onto the inner surface of capillaries. Then, they are cut into appropriate lengths and arranged on a single microchip to prepare a dual-analyte sensing system. The concept proposed here offers advantages inherent to using a planar microfluidic device and of chemical functionality of immobilized molecules. Therefore, we expect to fabricate various types of chemically functionalized microfluidic devices soon.

Journal Article↗

A microfluidic device for conducting gas-liquid-solid hydrogenation reactions.

We have developed an efficient system for triphase reactions using a microchannel reactor. Using this system, we conducted hydrogenation reactions that proceeded smoothly to afford the desired products quantitatively within 2 minutes for a variety of substrates. The system could also be applied to deprotection reactions. We could achieve an effective interaction between hydrogen, substrates, and a palladium catalyst using extremely large interfacial areas and the short path required for molecular diffusion in the very narrow channel space. This concept could be extended to other multiphase reactions that use gas-phase reagents such as oxygen and carbon dioxide.

Journal Article↗

Micro wet analysis system using multi-phase laminar flows in three-dimensional microchannel network.

A three-dimensional microchannel network with two-level crossings of channels was constructed in a glass microchip by sandwiching an insulating glass plate between two glass plates with microchannels followed by thermal bonding. Pressure-driven stable multi-phase laminar flows inside the three-dimensional channel network were realized by balancing flow rates of syringe pumps. Micro unit operations for mixing, reaction, solvent extraction, and detection were properly arranged in the multi-phase laminar flows, so that four parallel analyses, comprising twenty unit operations in total, could be integrated onto a single chip. Two chelating reagents and two sample solutions containing heavy metal ions (Fe(ii) or Co(ii)) were mixed and reacted in four different combinations using the three-dimensional channel network. After chelating reactions were completed, post processing (solvent extraction or addition of acid) was applied to each solution stream to remove the interferences of coexisting metal ions. Finally, target metal complexes were detected using a thermal lens microscope (TLM). Integrity of the micro system was confirmed by qualitative analysis of Fe(ii) and Co(ii). This is the first example of continuous flow chemical processing utilizing multi-phase laminar flow realized in a three-dimensional channel network.

Glass↗

Integration of an immunoassay system into a microchip for high-throughput assay.

An immunosorbent assay system was integrated into a glass microchip. The scale merits of liquid microspace for molecular behavior contributed remarkably to reduced assay time, and troublesome operations required for conventional immunosorbent assays could be replaced by simple operations. Moreover, a micro-immunoassay system suitable for simultaneous assay of multiple samples was constructed on a microchip. The chip had branching multichannels and four reaction and detection regions; thus the constructed system could process four samples at a time with only one pump unit. A higher throughput assay was realized with the branching structure chip.

Animals↗

Drug response assay system in a microchip using human hepatoma cells.

A microchip-based cell response assay system to an anticancer agent was developed. The hepatoma cell line HepG2 was used to assess the effects of an anticancer agent, doxorubicin. The required cell number was reduced by two orders, and the observation of the time course of cell response became possible. The system clearly showed that treatment with higher doses of the drug or longer exposure times gave more effects to cells. The possibilities of novel drug response studies or toxicity assay system were demonstrated.

Antibiotics, Antineoplastic↗

Spectroscopic analysis of liquid/liquid interfaces in multiphase microflows.

Microscopic quasi-elastic laser scattering (muQELS) spectroscopy has been developed for analysis of interfacial phenomena at laminar multiphase microflow in a microchannel. Transport phenomena of a metal chelate through a water/toluene interface were measured, and transient adsorption of the chelate in the initial step of the transport was measured. A water/methanol miscible interface was also measured, and the interfacial free energy of a miscible interface was determined for the first time. The muQELS is expected to be very effective not only for physicochemical investigations of transport and mixing, but also for elemental process analysis of heterogeneous reactions.

Journal Article↗

Microchip-based chemical and biochemical analysis systems.

This review focuses on chemical and biochemical analysis systems using pressure-driven microfluidic devices or microchips. Liquid microspace in a microchip has several characteristic features, for example, short diffusion distances, high specific interfacial area and small heat capacity. These characteristics are the key to controlling micro unit operations and constructing new integrated chemical systems. By combining multiphase laminar flow and the micro unit operations, such as mixing, reaction, extraction and separation, continuous flow chemical processing systems are realized in the microchip format. By applying these concepts, several different analysis systems were successfully integrated on a microchip. In this paper, we introduce the microchip-based chemical systems for wet analysis of cobalt ion, multi-ion sensors, immunoassay, and cellular analysis.

Animals↗

Microchannel-assisted thermal-lens spectrometry for microchip analysis.

Microchannel-assisted thermal lens spectrometry (MATLS) was developed for microchip analysis. This method utilized a photothermal effect in a very small space and rapid thermal conduction between a solid-liquid interface to produce a temperature gradient in the microchannel. In order to examine the mechanism experimentally, we constructed a detection system of laser defocus setup in which an excitation beam was not tightly focused, but it irradiated the microchannel homogeneously. The signal intensity dependence on modulation frequency of excitation and on solvent was investigated with the laser defocusing setup. The results of this investigation indicated that the mechanism of MATLS worked as expected. Since the mechanism of MATLS does not require directivity and coherence of the laser beam, other incoherent lightsources can be used as excitation light for sensitive detections. Finally, we considered some future applications utilizing the mechanism.

Semiconductors↗

Chemicofunctional membrane for integrated chemical processes on a microchip.

Here we report a design and synthesis of a chemically functional polymer membrane by an interfacial polycondensation reaction and multilayer flow inside a microchannel. Single and parallel dual-membrane structures are successfully prepared by using organic/aqueous two-layer flow and organic/aqueous/organic three-layer flow inside the microchannel followed by an interfacial polycondensation reaction. By using the inner-channel membrane, permeation of ammonia species through the inner-channel membrane is successfully achieved. Furthermore, horseradish peroxidase is immobilized on one side of the membrane surface to integrate the chemical transform function onto the inner-channel membrane. Here substrate permeation through the membrane and subsequent chemical transformation at the membrane surface are realized. The polymer membrane prepared inside the microchannel has an important role in ensuring stable contact of different phases such as gas/liquid or liquid/ liquid and the permeation of chemical species through the membrane. Furthermore, membrane surface modification chemistry allows chemical transformation of permeated chemical species. These methods are expected to lead to development of complicated and sophisticated chemical systems involving membrane permeation and chemical reactions.

Journal Article↗

Chemical processing on microchips for analysis, synthesis, and bioassay.

This review describes our recent research on miniaturization of chemical systems. We have developed a miniaturization methodology based on pressure-driven multiphase laminar flow and a highly sensitive detection tool, the thermal lens microscope. Some representative applications of the methodology in the fields of analysis, synthesis, and bioassay are described.

Microscopy↗

An interface chip connection between capillary electrophoresis and thermal lens microscope.

A thermal lens microscope (TLM) detection of capillary electrophoresis (CE) utilizing microchip technology was developed. Fused-silica capillaries with an inner diameter of 50 microm were directly connected to a microchannel in a microchip. The detection limit by TLM was estimated as 2.8 x 10(-7) absorbance by measuring pure water. The detection limit of derivatized amino acids determined by CE-TLM was estimated as 2.4 x 10(-8) M, which was 100 times lower than that of conventional absorbance detection.

Amino Acids↗