PubMed Health⌕ Search

Biomedical subjects

Takehisa Matsuda

Publications and source records attributed to Takehisa Matsuda.

At least 55 records · Page 3Linked to original sources

Novel visible-light-induced photocurable tissue adhesive composed of multiply styrene-derivatized gelatin and poly(ethylene glycol) diacrylate.

A novel photocurable tissue adhesive glue, which is composed of styrene-derivatized (styrenated) gelatin, poly(ethylene glycol) diacrylate (PEGDA), and carboxylated camphorquinone in phosphate-buffered saline (PBS), was prepared. The prototype formulation suitable for arterial repair was determined based on the gel yield, degree of swelling, tissue adhesive strength, and breaking (or burst) strength in vitro. The formulated photocurable tissue adhesive glue with an appropriate viscosity was converted to a water-swollen gel within 1 min of visible light irradiation. The tissue adhesive glue, which was coated on a rat abdominal aorta incised with a pair of scissors, was immediately converted to a swollen gel upon subsequent irradiation with visible light, and concomitantly hemostasis was completed. Histological examination showed that the produced gel was tightly adhered to the artery shortly after photoirradiation. The gel gradually degraded with time and was completely absorbed within 4 weeks after treatment. These results indicate that the photocurable glue developed here may serve as a tissue adhesive glue applicable to vascular surgery.

Animals↗

Coaxial double-tubular compliant arterial graft prosthesis: time-dependent morphogenesis and compliance changes after implantation.

In order to reduce the compliance mismatch between the native artery and the artificial graft, we have developed a coaxial double-tubular compliant graft, using multiply micropored segmented polyurethane (SPU) thin films, which mimics the relationship between the intraluminal pressure and vessel internal diameter (P-D) of the native artery (termed "J" curve). The graft was coaxially assembled by inserting a high-compliance inner tube with a heparin-immobilized photocured gelatin coating layer into a low-compliance outer tube with a photocured hydrophilic polymer coating layer. Twenty-eight coaxial double-tubular compliant grafts were implanted into the canine common carotid arteries in an end-to-end fashion for up to 12 months. The overall patency rate was 86% (24/28), and neither rupture nor aneurysmal formation was observed. A neoarterial wall was formed via transanastomotic and transmural tissue ingrowth, resulting in neoarterial tissue formation on the luminal surface and into the intertubular space of the double-tubular graft, accompanied by mainly myofibroblasts and inflammatory cells in the early stage and endothelialization and collagen-rich extracellular matrices in the late stage of implantation. Surrounding-tissue adhesion with the outer tube was prevented by the hydrophilic polymer coating. Although the J curve of the implanted prototype model was preserved 1 month after implantation, the impaired J curves were observed because of tissue ingrowth and tissue adhesion between the outer surface of the inner tube and the surrounding tissues 3 and 6 months after implantation. At 12 months after implantation, however, the implanted coaxial double-tubular graft exhibited high compliance due to biodegradation of the SPU films.

Animals↗

Photo-control of the interaction between endothelial cells and photo-cation generatable water-soluble polymers.

In this study photo-control of the non-biospecific interaction between endothelial cell membranes and photo-cation generatable water-soluble polymers were examined. The water-soluble polymers contained triphenylmethane leucohydroxide (malachite green) groups (contents: 0.4 and 1.6 mol%), which dissociate into triphenylmethyl cations and counter hydroxide ions upon ultraviolet light (UV) irradiation, and were prepared by free radical copolymerization of diphenyl(4-vinylphenyl)methane leucohydroxide and acrylamide. The nature and magnitude of the interaction was quantitatively assessed by direct luminescence measurement of the intracellular calcium ion concentration using a calcium-sensitive photoprotein, aequorin. When a PBS buffer of the photoreactive copolymers were added, prior to UV irradiation, to a PBS suspension of cultured bovine endothelial cells loaded with aequorin, no detectable elevation of Ca(2+) was measured. In contrast, cationic copolymers, derived from the photoreactive copolymers after UV irradiation at a wavelength of 290<lambda<410 nm, induced an immediate transient increase in the cytosolic free Ca(2+) concentration due to a Ca(2+) inflow from the extracellular space into the cells, which may be due to non-biospecific transmembrane stimulation. Longer UV irradiation exposures of the copolymers and higher concentrations of the polymers, with higher contents of the photodissociable group, resulted in more Ca(2+) inflow with little cellular damage. The photo-cation generatable copolymers developed here made possible to control the non-biospecific interaction with endothelial cell membranes by UV irradiation condition, and composition and amount of the copolymer.

Animals↗

Application of nanoparticle technology for the prevention of restenosis after balloon injury in rats.

Restenosis after percutaneous coronary intervention continues to be a serious problem in clinical cardiology. Recent advances in nanoparticle technology have enabled us to deliver an antiproliferative drug selectively to the balloon-injured artery for a longer time. NK911, which is a core-shell nanoparticle of polyethyleneglycol-based block copolymer encapsulating doxorubicin, accumulates in vascular lesions with increased permeability. We first confirmed that balloon injury caused a marked and sustained increase in vascular permeability (as evaluated by Evans blue staining) for a week in the rat carotid artery. We then observed that intravenous administration of just 3 times of NK911, but not doxorubicin alone, significantly inhibited the neointimal formation of the rat carotid artery at 4 weeks after the injury in both a single- and double-injury model. Immunostaining demonstrated that the effect of NK911 was due to inhibition of vascular smooth muscle proliferation but not to enhancement of apoptosis or inhibition of inflammatory cell recruitment. Measurement of vascular concentrations of doxorubicin confirmed the effective delivery of the agent to the balloon-injured artery by NK911 in both a single- and double-injury model. RNA protection assay demonstrated that NK911 inhibited expression of several cytokines but not that of apoptosis-related molecules. NK911 was well tolerated without any adverse systemic effects. These results suggest that nanoparticle technology to target vascular lesions with increased permeability is a promising and safe approach for the prevention of restenosis after balloon injury. The full text of this article is available at http://www.circresaha.org.

Animals↗

In vivo leukocyte cytokine mRNA responses to biomaterials are dependent on surface chemistry.

An in vivo mouse cage implant system was used to determine whether leukocyte cytokine mRNA responses to implanted biomaterials were dependent on surface chemistry. Surfaces displaying various chemistries (hydrophobic, hydrophilic, anionic, and cationic) were placed into stainless steel cages and implanted subcutaneously. Semiquantitative RT-PCR analyses revealed that hydrophilic surfaces showed a decreased expression of proinflammatory cytokines, IL-6 and IL-8, and pro-wound healing cytokines, IL-10 and TGF-beta by adherent cells, and mRNA levels of the proinflammatory cytokine, IL-1beta, and the pro-wound healing cytokine IL-13 were decreased in surrounding, exudate cells. Cytokine responses by adherent and exudate cells to hydrophobic, anionic and cationic surfaces were similar and indicative of a strong inflammatory response at the earliest time point followed by a wound healing response at later time points. However, no differences in the types or levels of exudate cells for any of the surfaces or the empty cage at each of the respective time points were observed, indicating their respective biocompatibility. These studies identify hydrophilic surface chemistries as having significant effects on leukocyte cytokine responses in vivo by decreasing the expression of inflammatory and wound healing cytokines by inflammatory cells adherent to the biomaterial as well as present in the surrounding exudate.

Animals↗

Fabrication of micropored elastomeric film-covered stents and acute-phase performances.

To prevent thrombus formation in the acute phase and restenosis in the subacute to chronic phase after stenting of atherosclerotic arteries, we developed a covered stent with a micropored elastomeric film, the blood-contacting surface of which was coated with a photocured gelatin layer immobilized with heparin. Segmented polyurethane (SPU) film (30 microm in wall thickness) as a cover material was multiply micropored by excimer laser-directed microprocessing (pore diameter, 30 microm; interpore distance, 125 microm). An aqueous mixed solution of benzophenone-derivatized gelatin and heparin was coated on the micropored SPU film. Upon ultraviolet light irradiation, a thin layer of a gelatin gel immobilized with heparin was formed and simultaneously fixed on the SPU film. The fully covered stents were assembled by wrapping a balloon-expandable stent with gelatin/heparin gel-layered SPU film and subsequently suturing and then gluing. To assess the validity of this covered stent in vivo, "half-covered" stents, in which half at the distal side was covered with the gel-layered SPU film, was implanted in rabbit common carotid arteries (about 3 mm in diameter). After 3 months of implantation, all the half-covered stents (n = 7) were patent. Regardless of the covered or noncovered region of the stents, the entire luminal surface of the stents was fully endothelialized and a thin neointimal tissue was formed. The potential advantages of a covered stent as designed above are discussed.

Animals↗

Canine endothelial progenitor cell-lined hybrid vascular graft with nonthrombogenic potential.

OBJECTIVE: We sought to fabricate a compliant engineered vascular graft (inner diameter of approximately 4.5 mm and length of 6 cm) lined with endothelial progenitor cells derived from circulating peripheral canine blood and to verify its nonthrombogenicity potential in vivo. METHODS: Autologous circulating endothelial progenitor cells derived from the peripheral veins of 6 adult mongrel dogs were isolated by using a density gradient method. The cells were proliferated in vitro in EGM-2 culture medium, prelined on the luminal surface of in situ-formed collagen type I meshes as an extracellular matrix, and wrapped with a segmented polyurethane thin film with multiple micropores as a compliant scaffold. After canine carotid arteries were bilaterally implanted with these grafts for 1 and 3 months, microscopic observation, histologic staining, and immunochemical staining were performed to evaluate morphogenesis. RESULTS: After 33.3 +/- 10.5 days of culture in vitro, 4.2 +/- 1.2 x 10(6) endothelial progenitor cells were obtained. Eleven of the 12 engineered vascular grafts were patent. The grafts possessed smooth, glistening, and ivory-colored luminal surfaces at the predetermined observation period up to 3 months. The intimal layer was covered with confluent, cobblestone-like monolayered cells that were positively stained with factor VIIIB-related antigen. The thickness of the neoarterial walls was approximately 300 microm at 3 months after implantation. A few smooth muscle cells were observed in the medial tissue, and fibroblasts dominated the adventitial tissue. CONCLUSION: Circulating endothelial progenitor cells could be a substitute source of endothelial cells for endothelialization on small-diameter-vessel prostheses to ensure nonthrombogenicity.

Actins↗

Fabrication of endothelial progenitor cell (EPC)-seeded intravascular stent devices and in vitro endothelialization on hybrid vascular tissue.

Rapid re-endothelialization at an atherosclerotic lesion after balloon inflation or stent deployment may be essential for reducing or preventing local thrombus formation and restenosis. In order to prevent these complications via enhanced rapid re-endothelialization, we fabricated two types of endothelial progenitor cell (EPC)-seeded intravascular stent devices. One was a photocured gelatin-coated metallic stent, and the other was a microporous thin segmented polyurethane (SPU) film-covered stent on which photocured gelatin was coated. Both devices were seeded with ex vivo expanded EPCs obtained from canine peripheral blood. Seeded EPCs formed confluent monolayers onto surfaces of both photocured gelatin-coated stent struts and SPU film, and a majority of cells remained on surfaces of stents after stent expansion. The EPC-seeded stent was expanded in a tubular hybrid vascular medial tissue composed of vascular smooth muscle cells and collagen as an arterial media mimic. After 7-day culture, EPCs, which migrated from the stent struts, proliferated and endothelialized the luminal surfaces of the hybrid vascular medial tissue. This in vitro pilot study prior to in vivo experiments suggests that on-stent cell delivery of EPCs may be novel therapeutic devices for re-endothelialization or endothelium lining or paving at an atherosclerotic arterial wall, resulting in the prevention of on-stent thrombus formation and in-stent restenosis, as well as the rapid formation of normal tissue architecture.

Animals↗

Phosphorylcholine-endcapped oligomer and block co-oligomer and surface biological reactivity.

Phosphorylcholine (PC)-endcapped oligomer and block co-oligomer were prepared by employing a photoiniferter-based quasi-living polymerization technique. The designed oligomer had a PC polar head group attached to an alkylene chain at one end of the molecule and an oligo(styrene) (oligoST) segment at the other end. In the co-oligomer, an oligo(N,N-dimethylacrylamide) (oligoDMAAm) segment was inserted between both ends of the oligomer mentioned above. Surface coating of these amphiphilic substances, using an appropriate coating procedure, resulted in a very hydrophilic characteristic, suggesting that the oligoST anchored on the substrate and the PC polar head group was exposed to or located on the outer coating layer. Non-cell adhesivity in serum-containing medium was observed, while slightly reduced protein adsorption was observed. Thus, PC-endcapped oligomer and block co-oligomer appear to function as a biocompatible coating.

Biomimetic Materials↗

Quasi-living surface graft polymerization with phosphorylcholine group(s) at the terminal end.

A surface graft polymer with one or two phosphorylcholine (PC) polarheads at the terminus of the growing chain end was prepared by sequential reactions on a glass substrate. The dithiocarbamate group covalently bound to glass surfaces was derivatized with one or two PC groups and then irradiated with ultraviolet light in the presence of N,N-dimethylacrylamide (DMAAm). X-ray photoelectron spectroscopy, wettability measurements and dye staining experiment for the PC group showed that the resultant graft copolymers were produced via iniferter-based quasi-living radical polymerization, in which the polyDMAAm graft chain contains one or two PC groups at the terminal end of the graft chain. These polymer surface grafts may help provide biocompatibility.

Acrylamides↗

Intralumenal tissue-engineered therapeutic stent using endothelial progenitor cell-inoculated hybrid tissue and in vitro performance.

Rapid reendothelialization at an atherosclerotic lesion after balloon or stent inflation may be essential for maintaining homeostatic tissue function, which could reduce or prevent restenosis. We devised an endothelial progenitor cell (EPC)-enriched tubular hybrid tissue and mounted it on a small-diameter metallic stent (outer diameter, 1.5 mm), which is used for intravascular angioplasty to atherosclerotic lesions. This study addressed the fabrication technique and in vitro performance to verify lumenal endothelialization. A thin collagenous tubular tissue was prepared by contraction of collagen fibers by inoculated EPCs, which were isolated from canine peripheral blood and expanded ex vivo, in a collagen gel formed in a mold. An EPC-inoculated hybrid tissue-covered stent, loaded on a balloon catheter, was inserted into a tubular hybrid vascular medial tissue inoculated with smooth muscle cells (SMCs) as an arterial media mimic, and subjected to balloon inflation for enlargement (outer diameter, 3 mm), followed by balloon deflation. The EPC-inoculated hybrid tissue-covered stent tightly adhered to the lumenal surface of the hybrid medial tissue. On culture, EPCs in the hybrid tissue migrated and proliferated to form a completely endothelialized lumenal surface at stented sites as well as sites adjacent to the vascular hybrid medial tissue with the prolongation of culture. This in vitro pilot study before in vivo experiments suggests that an EPC-inoculated hybrid tissue-covered stent may be a novel therapeutic device for reendothelialization or paving with EPC-enriched tissue at an atherosclerotic arterial wall, resulting in the prevention of restenosis and the rapid formation of normal tissue.

Animals↗

System-engineered cartilage using poly(N-isopropylacrylamide)-grafted gelatin as in situ-formable scaffold: in vivo performance.

Our previous study showed that cartilaginous tissue can be engineered in vitro with articular chondrocytes and poly(N-isopropylacrylamide)-grafted gelatin. This short-term in vivo study for cartilage repair was performed to screen a candidate method for a long-term study. In our previous in vitro study, however, two potential problems with the tissue-engineered cartilage were identified: (1). leakage of the transplant due to temperature decline and (2). concave deformation of transplant due to compressive loading. To solve these problems, we investigated in this study the usefulness of suturing with two different covering materials (periosteum or collagen film) and preculturing an engineered tissue for 2 weeks. PNIPAAm-gelatin-based engineered cartilage samples were evaluated at 5 weeks after operation by gross and microscopic examination. Leakage occurred only in specimens without precultured tissue and with a collagen film. Minimal surface deformation occurred in all specimens with precultured tissue. The score on gross examination showed that transplants with precultured tissue acquired a higher score than did the others. Histological evaluation showed a minimal foreign-body response of PNIPAAm-gelatin in all specimens and higher maturity as a cartilaginous tissue in specimens with precultured tissue. These results indicate that transplantation with precultured tissue may be a suitable method for a long-term in vivo study.

Acrylic Resins↗

Human endothelial progenitor cell-seeded hybrid graft: proliferative and antithrombogenic potentials in vitro and fabrication processing.

In this article, we show that human endothelial progenitor cells (EPCs) in circulating peripheral blood may be a novel cell source for a cell-incorporated engineered vascular graft. Cultures of human peripheral blood mononuclear cells collected by the density gradient technique developed highly proliferative EPC colonies, which expanded with culture time. The production rates of antiplatelet substances such as endothelial-type nitric oxide synthase and 6-keto-prostaglandin-F(1)-alpha were approximately one-third and approximately one-half of those of mature endothelial cells (ECs), respectively. On the other hand, the tissue-type plasminogen activator production rate of EPCs was almost the same as that of ECs. EPCs were seeded and cultured on a small-diameter compliant graft (inner diameter, 1.5 mm) made of microporous segmented polyurethane film coated with a photo-reactive gelatin layer, and subsequently subjected to hydrodynamic shear stress by ex vivo circulation. EPCs fully covering the graft elongated and aligned themselves with the direction of the flow, resulting in the production of an integrated EPC-engineered graft. These results indicate that EPCs, which have high proliferative potential and high antithrombogenic potential, comparable to those of ECs, are a suitable cell source for cardiovascular tissue engineering.

Blood Cells↗

Tissue-engineered cartilage using an injectable and in situ gelable thermoresponsive gelatin: fabrication and in vitro performance.

An injectable and in situ gelable scaffold can fully fill the space of cartilaginous defects of complex shapes. The authors attempted to develop a novel injection-driven technique for cartilage repair using a thermoresponsive gelatin, poly(N-isopropylacrylamide)-grafted gelatin (PNIPAAm-gelatin). A mixed solution of chondrocytes was isolated from a Japanese white rabbit and PNIPAAm-gelatin was spontaneously solidified at 37 degrees C and cultured. The number of cells in the gel with a poly(N-isopropylacrylamide) (PNIPAAm) chain of high molecular weight (1.3 x 10(5) g/mol) and at low concentration (5 w/v%) remained unchanged irrespective of culture time, and minimal cell death and little cell proliferation were observed. A round-shaped morphology was dominantly restored even at 1 week of incubation. The cell population in the G(0)/G(1) phase was high (more than 90%), and this gradually increased with culture time. Type II collagen and sulfated glycosaminoglycan (s-GAG) were detected in the tissue-engineered cartilage, but a small amount of type I collagen was also detected. Total collagen and s-GAG increased in level close to those of native hyaline cartilage over 12 weeks of culture. Mechanical properties of the tissue-engineered cartilage responding to loading and unloading of compression force tend to approach those of native hyaline cartilage with culture time. These results suggest that PNIPAAm-gelatin may be a suitable in situ formable scaffold for cartilage repair.

Acrylic Resins↗

Occlusion of experimental aneurysms with heparin-loaded, microporous stent grafts.

OBJECTIVE: An embolization technique using a stent graft has been developed to replace the conventional type of direct surgery or neurointervention with platinum coils and/or bare stents. The utility of a commercially available metal stent wrapped with a microporous elastomeric film coated with a thin, heparin-loaded, photocured gelatinous layer for the treatment of experimental carotid artery sidewall aneurysms in dogs was evaluated. METHODS: The stent graft was used for embolization of experimental carotid artery aneurysms in dogs. The aneurysms were prepared bilaterally in canine carotid arteries with branching of an external jugular vein patch. RESULTS: The entries into all of the aneurysms were occluded immediately after placement of the stent grafts, and the aneurysms were embolized by thrombus formation even 1 week after deployment. All of the parent carotid arteries in which stent grafts were placed were patent, without severe stenosis, immediately (n = 2), 1 week (n = 4), 1 month (n = 3), and 3 months (n = 4) after placement. Scanning electron microscopy demonstrated that the luminal surfaces of the stent grafts were entirely endothelialized as soon as 1 week after placement, via transmural tissue ingrowth through the micropores formed in the covering film. CONCLUSION: The stent graft we have developed seems to be highly promising for the treatment of aneurysms, especially with respect to immediate termination of blood inflow for aneurysm occlusion and rapid endothelialization in the aneurysm neck.

Aneurysm↗

[Regulatory role of mechanical stress response in cellular function: development of new drugs and tissue engineering].

The investigation of mechanotransduction in the cardiovascular system is essentially important for elucidating the cellular and molecular mechanisms involved in not only the maintenance of hemodynamic homeostasis but also etiology of cardiovascular diseases including arteriosclerosis. The present review summarizes the latest research performed by six academic groups, and presented at the 75th Annual Meeting of the Japanese Pharmacological Society. Technology of cellular biomechanics is also required for research and clinical application of a vascular hybrid tissue responding to pulsatile stress. 1) Vascular tissue engineering: Design of pulsatile stress-responsive scaffold and in vivo vascular wall reconstruction (T. Matsuda); 2) Cellular mechanisms of mechanosensitive calcium transients in vascular endothelium (M. Oike et al.); 3) Cross-talk of stimulation with fluid flow and lysophosphatidic acid in vascular endothelial cells (K. Momose et al.); 4) Mechanotransduction of vascular smooth muscles: Rate-dependent stretch-induced protein phosphorylations and contractile activation (K. Obara et al.); 5) Lipid mediators in vascular myogenic tone (I. Laher et al.); and 6) Caldiomyocyte regulates its mechanical output in response to mechanical load (S. Sugiura et al.).

Animals↗

Photocontrol of cell adhesion and proliferation by a photoinduced cationic polymer surface.

In this study photoinduced cation generation, based on the photochemical properties of malachite green (MG), was used for the surface design and in vitro photochemical control of cell adhesion and proliferation. The MG-derivatized surface was prepared by coating a photoreactive polymer as a substrate onto a poly(ethylene terephthalate) (PET) sheet. The photoreactive polymer was radical copolymer of styrene with the MG-derivatized monomer diphenyl(4-vinylphenyl)methane leucohydroxide (degree of substitution of MG unit: 12.4 mol%). Water contact angle measurements and X-ray photoelectron spectroscopy revealed high hydrophobicity and homogeneous distribution of the MG groups on the outermost surface of the coated film, respectively. When the coated film was exposed to ultraviolet light (UV) irradiation at wavelengths of 290-410 nm, a time-dependent color change of the film was observed from pale yellow, before irradiation, to green. These results indicated generation of cations on the film surface by photochemical cation generation of the MG groups, which was quantitatively characterized by force versus distance curves measurements in atomic force microscopic (AFM) observation using a carboxylated AFM tip. The seeding and culture of endothelial cells showed a marked reduction in adhesion on the nonirradiated coated film surface, whereas the UV-irradiated surface promoted cell adhesion and proliferation except for incubation in serum-free medium, which was similar to commercial tissue culture PET sheet. These observations may be due to adsorption of cell adhesive proteins, typified by fibronectin, in serum-containing medium onto the cationized photoreactive copolymer surface by electrostatic interactions.

Animals↗

Liquid acrylate-endcapped biodegradable poly(epsilon-caprolactone-co-trimethylene carbonate). I. Preparation and visible light-induced photocuring characteristics.

Photocurable liquid biodegradable copolymers were prepared by ring-opening copolymerization of epsilon-caprolactone (CL) and trimethylene carbonate (TMC) in the presence of a multifunctional hydroxyl group-bearing substance (di-, tri-, and tetra-functional alcohol and poly(ethylene glycol) (PEG) and its four-branched derivative) as an initiator and subsequent endcapping with acryloyl chloride at their hydroxyl terminals. These multifunctional, viscous liquid copolymers (molecular weights; approximately 2 x 10(3) to 7 x 10(3) g/mol) were converted to crosslinked solids by visible-light irradiation in the presence of camphorquinone as an initiator. The photocuring rate of these copolymers was enhanced by both higher functionality and lower molecule weight of the copolymers used. The photocuring rate depended on the amount of reducing agent (methacrylic acid 2-dimethylaminoethyl ester). Upon immersion in a phosphate buffer solution (pH 7.4), hydrolysis occurred preferentially on the surface except for photocured PEG-based copolymers that were degraded faster via both surface erosion and bulk degradation than low molecular weight alcohols-based copolymers. Cylindrical photocured constructs prepared by photoirradiation to the whole body in a mold filled with the liquid copolymer was demonstrated as an example of shape fabrication of biodegradable biomedical devices.

Acrylates↗