PubMed Health⌕ Search

Biomedical subjects

Takehisa Matsuda

Publications and source records attributed to Takehisa Matsuda.

At least 73 records · Page 4Linked to original sources

Liquid acrylate-endcapped biodegradable poly(epsilon-caprolactone-co-trimethylene carbonate). II. Computer-aided stereolithographic microarchitectural surface photoconstructs.

Advanced micromedical devices may require computer-aided photofabrication, by which microarchitectural surface design and entire macroshaped body design are feasible. Liquid acrylate-endcapped poly(epsilon-caprolactone-co-trimethylene carbonate)s, poly(CL/TMC)s, prepared using trimethylene glycol (TMG) or poly(ethylene glycol) (PEG) as an initiator and an acrylate group for subsequent terminal capping, were used as photocurable copolymers. The stereolithographically microarchitectured photoconstructs were prepared using a custom-designed apparatus with a moving ultraviolet (UV) light pen driven by a computer-assisted design program. The prepared photoconstructs included microneedles, a microcylinder and microbanks on surfaces. In vitro hydrolytic degradation proceeded with surface erosion when hydrophobic TMG-based photocured copolymers were employed, whereas very fast degradation of hydrophilic PEG-based photocured copolymers probably via concerted actions of surface erosion and bulk degradation was observed. In vivo hydrolytic behavior upon subcutaneous implantation in rats indicated that surface erosion proceeded for TMG-based photoconstructs. Anti-inflammatory drug (indomethacin) loading into microneedle-structured surfaces minimized inflammatory reactions. The possible biomedical microarchitectural three dimensinal in biomedical application photoconstructs was discussed.

Acrylates↗

Local expression of C-type natriuretic peptide suppresses inflammation, eliminates shear stress-induced thrombosis, and prevents neointima formation through enhanced nitric oxide production in rabbit injured carotid arteries.

We previously observed that adenovirus-mediated expression of C-type natriuretic peptide (CNP) markedly inhibits neointima formation after balloon injury in rat carotid arteries, suggesting that CNP has multiple effects over its modest inhibitory effect on cellular proliferation. We hypothesized that local expression of CNP might have antithrombotic and antiinflammatory effects. Balloon-injured rabbit carotid arteries were infected with an adenovirus expressing human CNP (AdCNP), human tissue factor pathway inhibitor (AdTFPI), or bacterial beta-galactosidase (AdLacZ) or infused with saline. Seven days later, shear stress-induced thrombosis was evaluated by cyclic flow variation (CFV), reflecting recurrent cycles of thrombus formation and dislodgment. CFV was observed in all AdLacZ-infected and saline-infused arteries but not in arteries infected with AdCNP or AdTFPI even in the presence of epinephrine. Injury increased the expressions of intracellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1) and infiltration of macrophages. However, these effects were markedly reduced in AdCNP-treated arteries but not in AdTFPI-infected ones. In AdCNP-infected arteries, injury-induced expression of inducible NO synthase (iNOS) was enhanced, leading to increased NO generation. Interestingly, when the enhanced NO production was inhibited, neither inhibitory effect was observed, and suppression of neointima formation by CNP was canceled. Our study demonstrates that overexpression of CNP shows antithrombotic and antiinflammatory effects and reduces neointima formation mainly through enhanced NO production.

Adenoviridae↗

Biomaterial adherent macrophage apoptosis is increased by hydrophilic and anionic substrates in vivo.

An in vivo rat cage implant system was used to identify potential surface chemistries that prevent failure of implanted biomedical devices and prostheses by limiting monocyte adhesion and macrophage fusion into foreign-body giant cells while inducing adherent-macrophage apoptosis. Hydrophobic, hydrophilic, anionic, and cationic surfaces were used for implantation. Analysis of the exudate surrounding the materials revealed no differences between surfaces in the types or levels of cells present. Conversely, the proportion of adherent cells undergoing apoptosis was increased significantly on anionic and hydrophilic surfaces (46 +/- 3.7 and 57 +/- 5.0%, respectively) when compared with the polyethylene terephthalate base surface. Additionally, hydrophilic and anionic substrates provided decreased rates of monocyte/macrophage adhesion and fusion. These studies demonstrate that biomaterial-adherent cells undergo material-dependent apoptosis in vivo, rendering potentially harmful macrophages nonfunctional while the surrounding environment of the implant remains unaffected.

Animals↗

Local delivery of low-dose docetaxel, a novel microtubule polymerizing agent, reduces neointimal hyperplasia in a balloon-injured rabbit iliac artery model.

OBJECTIVE: Docetaxel (DOC) is a novel microtubule polymerizing agent, with superior antiproliferative properties as compared to paclitaxel. DOC is therefore a potential therapeutic tool for the prevention of restenosis following angioplasty. However, DOC has systemic toxicity such as leukocytopenia, which occurs in a dose-dependent manner. To minimize such adverse effects, we carried out local delivery of low-dose DOC directly to injured vessel sites. METHODS: The rabbit iliac artery was denuded, and then DOC (2 mg) or control vehicle was administered locally 20 min, via a local drug delivery catheter. RESULTS: The levels of DOC in the plasma were within ng/ml range, eliminating hematopoietic side effects. Seven days after the local delivery (DOC: n=4, control: n=4), DOC decreased the number of Ki-67-labeled cells in the intima (DOC: 22 +/-10 vs. control: 66 +/- 18 cells/mm(2), P<0.01), indicating a decreased proliferative activity. At 28 days (DOC: n=8, control: n=8), computer-assisted morphometric analysis demonstrated that DOC significantly reduced the intimal area (DOC: 0.15 +/- 0.13 vs. control: 0.70 +/- 0.13 mm(2), P<0.01). There was also a decrease in medial area in the DOC-treated vessels (DOC: 0.62 +/- 0.17 vs. control: 1.13 +/- 0.38 mm(2), P<0.01). CONCLUSIONS: Local delivery of DOC, even after a single low-dose administration, effectively inhibits neointimal hyperplasia. Such administration is associated with a minimal likelihood of systemic adverse effects (leukocytopenia), but potentially induces local toxicity (a decrease in medial wall thickness) due to extensive cytotoxic effect.

Administration, Topical↗

Device-directed therapeutic drug delivery systems.

To increase the therapeutic effectiveness of device-directed drug delivery systems for diseased cardiovascular tissues and cancerous tissues, new devices and new functional biomaterials were devised to meet the requirements as listed below: drug-infusible balloon catheter, drug-releasable and covered stents, and in situ hydrogelation on and in cancerous tissues. New therapeutic strategies based on these devices were discussed.

Angioplasty, Balloon↗

Compliant design of artificial graft: compliance determination by new digital X-ray imaging system-based method.

The development of an artificial graft requires formulation of biomechanical design criteria. The compliance of artifical grafts, based on the intraluminal pressure-internal diameter (Pi-Di) relationship, was measured by a novel method using a digital X-ray imaging system coupled with an edge detection algorithm and a pressure transducer. The Pi-Di values were obtained from digital angiographic images under continuous inflation of a canine femoral artery anastomosed with an expanded poly(tetrafluoroethylene) (ePTFE) vascular graft as a model vessel with a pressurized contrast medium. The Di at Pi using an NIH Image software specially programmed for the entropy filter method, which enables the detection of the edge of the vessel phantoms of the images, was determined. The Pi-Di relationships showed a "J-shape" curve for the artery, a steeper line with a very low pressure-dependent distensibility for the ePTFE graft, and an intermediate curve for the anastomosis protion. The two indices for the vessel compliance, the stiffness parameter (beta value) and the diameter compliance (Cd), both of which were calculated from the Pi-Di relationships, were 10.6 and 6.8%/mmHg x 10(-2) for the artery, 164 and 0.51%/mmHg x 10(-2) for the ePTFE, and 14.4 and 5.5%/mmHg x 10(-2) for the anastomosis portion, respectively. This method can measure compliance at any portions of the sampling vessel in a single experiment on a real-time basis with very high accuracy, compared with conventional methods, and even in cases of intimal thickening and/or connective tissues-adhered vessels, and may serve to provide information on compliant design criteria of artificial and tissue-engineered graft.

Algorithms↗

Liquid photocurable biodegradable copolymers: in vivo degradation of photocured poly(epsilon-caprolactone-co-trimethylene carbonate).

Liquid photoreactive poly(epsilon-caprolactone-co-trimethylene carbonate)s endcapped with a coumarin group [coumarinated poly(CL/TMC)s] were prepared using tetra-functional hydroxylated substances such as pentaerythritol or four-branched poly(ethylene glycol), b-PEG. These coumarinated copolymers are tetra-branched and exist as a viscous liquid (MW 5 x10(3) approximately 7 x 10(3)). They were photocured by ultraviolet (UV) light irradiation to obtain a swelling or nonswelling solid under water, depending on the type of initiator used. The resultant films were implanted into the subcutaneous tissues of rats for up to 5 months. The photocured b-PEG-based copolymer was completely degraded and sorbed within a 1 month. On the other hand, surface-eroding degradation of pentaerythritol-based, coumarinated poly(CL/TMC) progressed with implantation time, and minimal recruitment of neutrophils, macrophages, and multinucleated giant cells was observed over the implantation period. Among the pentaerythritol-based copolymers, the fastest surface erosion was observed for the copolymer with the highest epsilon-caprolactone content. Microfabricated films with microarrays in which photoconstructs were stereolithographically prepared, using three different coumarinated copolymers at different regions, showed that upon implantation there was regionally differentiated biodegradation of microarrays, and the degree of region-specific biodegradation depended on the type of photocured copolymer. The observed tendency for biodegradation was in good agreement with that observed during implantation of individual films in vivo. This study also demonstrates that the use of multi-material-arrayed films enables the determination of different responses in vivo using only one sample.

Absorbable Implants↗

Visible-light-induced surface graft polymerization via camphorquinone impregnation technique.

A surface modification method that is particularly applicable to complexly shaped fabricated devices has long been awaited. In this article, we describe the visible-light-induced surface photograft polymerization technique by which an inner surface of the device is modified by visible-light irradiation through the external surface. Comphorquione, as a photoradical initiator, was impregnated on a segmented polyurethane surface by solvent soaking, followed by visible-light irradiation in the presence of monomers such as acrylamide and poly(ethylene glycol) methacrylate. The resultant surfaces were highly wettable with water, and surface chemical compositional analysis by X-ray photoelectron spectroscopy revealed that the surface was graft-polymerized with these monomers. The simple and widespread applicability of this surface modification technique to biomedical devices is discussed.

Biocompatible Materials↗

Arterial replacement with compliant hierarchic hybrid vascular graft: biomechanical adaptation and failure.

Two types of hybrid vascular grafts were hierarchically structured with an autologous smooth muscle cell (SMC)-inoculated collagen gel layer and an endothelial cell (EC) monolayer, and wrapped with different elasomeric scaffolds. Type A graft was wrapped with poly(urethane)-nylon mesh, and type B graft was wrapped with an excimer laser-directed microporous segmented polyurethane (SPU) film as the scaffold. Type A graft was more compliant than canine carotid arteries, whereas compliance of type B graft was close to that of native arteries. After implantation into canine carotid arteries for 1 month, all type A grafts were dilated due to loosening of the mesh, resulting in loss of prelined ECs and thrombus formation. In contrast, type B grafts developed a well-organized neoarterial wall composed of a confluent EC monolayer and SMC-resided medial tissue, resulting in only slightly appreciable thrombus and minimal tissue ingrowth 6 months after implantation. Compliance of type B graft was reduced at 6 month's implantation, which is mostly due to encapsulated connective tissue formed around the graft.

Anastomosis, Surgical↗

Local delivery of single low-dose of C-type natriuretic peptide, an endogenous vascular modulator, inhibits neointimal hyperplasia in a balloon-injured rabbit iliac artery model.

C-type natriuretic peptide (CNP) is an endogenous vascular modulator. In addition to vasodilation, CNP exerts multifunctions including anti-thrombus and anti-proliferation actions against vascular smooth muscle cells and myofibroblasts. Therefore, CNP is a potential therapeutic agent for the prevention of restenosis following angioplasty. The current study investigated whether local delivery of CNP, even at microgram levels about three orders of magnitude lower than doses (high milligram levels) used for systemic administration in the previous study, attenuates neointimal hyperplasia. The rabbit iliac artery was denuded, and then CNP (100 microg, n = 5) or control vehicle (n = 5) was administered locally over 20 min, via a local drug delivery catheter. During drug delivery, blood pressure was monitored with a high-fidelity micromanometer catheter. There was no significant decrease in arterial pressure immediately after the CNP administration. Four weeks after the treatment, computer-assisted morphometric analysis revealed significant reduction in the intimal area (CNP 0.44 +/- 0.27 versus control 0.96 +/- 0.20 mm2, p < 0.01), but no changes in the medial area (CNP 0.93 +/- 0.23 versus control 0.79 +/- 0.29 mm2, p = NS). This resulted in a significant decrease in the ratio of the intimal area to the medial area in CNP-treated vessels compared with control vessels (CNP 0.45 +/- 0.26 versus control 1.40 +/- 0.66, p < 0.05). Local delivery of a single low dose of CNP effectively inhibits neointimal hyperplasia with a minimal likelihood of compromising hemodynamics. Considering its multipotent actions and its role as an important regulator of the vascular system, this treatment may have a therapeutic advantage for clinical use.

Animals↗

Thermoresponsive artificial extracellular matrix: N-isopropylacrylamide-graft-copolymerized gelatin.

Poly(N-isopropylacrylamide)-graft-copolymerized gelatin (PNIPAM-gelatin) was prepared by iniferter-based photopolymerization of multiply derivatized dithiocarbamylated gelatin. PNIPAM-gelatins exhibited low critical solution temperature (LCST) immediately below the physiological temperature. PNIPAAm-gelatin-coated dishes induced cell adhesion at 37 degrees C but incomplete detachment at room temperature, whereas dishes coated with PNIPAM or a mixture of PNIPAAm and gelatin showed little cell adhesion. The mixture of PNIPAAm-gelatin and PNIPAAm induced cell adhesion at 37 degrees C and detachment at 20 degrees C: the degrees of cell adhesion and detachment depended on the mixed ratio of PNIPAAm-gelatin and PNIPAAm. Complete thermoresponsive adhesion and detachment were found for the mixture containing a small fraction of PNIPAAm-gelatin (approximately 5 wt% with respect to PNIPAAm; gelatin content in the mixture is 2.7 wt%). Such a mixture may serve as thermoresponsive cell matrix for fabrication of a tissue-engineered device.

Acrylamides↗

Pull-out mechanical measurement of tissue-substrate adhesive strength: endothelial cell monolayer sheet formed on a thermoresponsive gelatin layer.

Although adhesive strength of a single cell on substrates has been reported, the adhesive strength at the tissue-substrate interface has not been reported. However, the tissue-substrate adhesive strength must provide important criteria for performance of implant devices. This article deals with the tissue-substrate adhesive strength for fully endothelialized tissue, which was formed on commercial tissue culture dishes with or without a coating layer of thermoresponsive gelatin (poly(N-isopropylacrylamide)-grafted gelatin, which dissolves in water at room temperature but is precipitated at 37 degrees C). To determine tissue-substrate adhesive strength, a pull-out technique using a glue-coated cover glass was used. The adhesive strength of monolayered tissue on a noncoated dish was approximately 560 Pa or 230 nN/cell at 37 degrees C. For dishes coated with thermoresponsive gelatin, the adhesive strengths were 1050 Pa or 584 nN/cell at 37 degrees C, and 26 Pa or 14 nN/cell at room temperature. For noncoated dishes, delamination occurred mostly at the interface between the extracellular matrix (ECM) secreted by the cells and the dish surface; and for coated dishes, it took place fully at the interface between ECM and the dish surface. This technique enables determination of the adhesive strength between a full monolayered tissue and a substrate.

Animals↗

Newly designed compliant hierarchic hybrid vascular grafts wrapped with a microprocessed elastomeric film--I: Fabrication procedure and compliance matching.

The object of this study was to develop a compliant hybrid vascular graft minimally supported by an elastomeric scaffold for arterial replacement. The hybrid vascular grafts designed were composed of three layers: an inner surface lined with endothelial cells (ECs); a hybrid medial tissue composed of a collagenous gel embedded with smooth muscle cells (SMCs); and an outer layer made of a laser-processed micropored segmented polyurethane (SPU) film with the circular pore size (diameter 150 microm) but different film thickness (50-200 microm) and different pore-to-pore distances (1 or 4 mm). The approximate dimensions of the hybrid vascular graft without the SPU film were as follows: inner diameter, 5 mm; length, 5 cm; thickness, 50 microm. The intraluminal pressure-external diameter relationship was measured by infusion of a phosphate buffer solution into the hybrid vascular graft. Canine carotid arteries and commercially available ePTFE grafts served as controls. Decrease in the thickness of the SPU film and increase in the pore density of the SPU film increased the pressure-dependent distensibility of the hybrid vascular grafts. The thinner the film and higher the pore density, the more compliant was the hybrid graft. The pressure-induced distensibility of the designed hybrid graft was found to be close to that of native carotid arteries.

Animals↗

Newly designed compliant hierarchic hybrid vascular graft wrapped with microprocessed elastomeric film--II: Morphogenesis and compliance change upon implantation.

Hierarchic structured hybrid tubular vascular media composed of endothelial cells (ECs), which covered the luminal surface, and smooth muscle cells (SMCs), which resided in the tubular collagen gel, were wrapped with thin segmented polyurethane elastomeric films designed to provide compliance matching with native arteries and transmural tissue permeability using a laser-directed ablation technique to provide different pore densities. Two hybrid grafts with high and low pore densities (inner diameter: 150 microm and length: 4 cm), and exhibiting pressure-dependent distensibility in response to pulsatile pressure, were bilaterally implanted into canine common arteries for up to 6 months. Irrespective of the pore density, high patency was achieved and no dilation and bursting occurred. Maintenance of full endothelialization during the entire course of implantation period was observed for the graft wrapped with the film with higher pore density. On the other hand, the graft wrapped with the film with lower pore density exhibited markedly reduced endothelialization at a later period of implantation, probably due to delamination of neoarterial tissue from the segmented polyurethane (SPU) surface. There were some differences in transmural tissue ingrowth between the two grafts. At anastomotic sites, neoarterial thickness for type A graft was smaller than that for type B graft regardless of the implantation period. Slightly reduced compliance was observed for both types of grafts at the sixth month of the implantation period. This study indicates that a hybrid vascular graft minimally supported with a thin elastomeric film can be used to replace diseased arteries if micropores are well designed for tissue permeability and anchoring.

Animals↗

Embolization of experimental aneurysms using a heparin-loaded stent graft with micropores.

PURPOSE: For percutaneous transluminal angioplasty (PTA), a heparin-loaded stent graft, composed of a commercially available metallic stent with a microporous and surface-modified thin film, has been developed. Early controlled endothelialization is promoted by a regular array of micropores produced by an excimer laser ablation technique. Early thrombus is prevented by a drug delivery system established by impregnation of photoreactive gelatin with heparin. Our stent grafts were used for embolization of experimental carotid aneurysms with an autologous external jugular vein patch in dogs. MATERIALS AND METHODS: At 1 month after formation, the aneurysms were occluded with stent grafts. Affected arteries were removed with the aneurysms, immediately (two aneurysms in one dog), 1 week (four aneurysms in two dogs), 1 month (three aneurysms in two dogs) and 3 months (four aneurysms in two dogs) after embolization, and were studied histologically to evaluate patency and endothelialization over the intraluminal surface of the thin film. RESULTS: Treated carotid arteries were all patent with occluded aneurysms completely at any periods. Even at 1 week after embolization, endothelialization was confirmed on the surface of the stent graft on the lumen side. At 1 and 3 months, all treated aneurysms with enough patent parent arteries were filled with organized tissues and completely occluded. CONCLUSION: Our developed stent graft appears to be promising for the treatment of aneurysms, especially with respect to immediate termination of blood inflow and early endothelialization in the neck of the aneurysm.

Aneurysm↗

Photocurable liquid biodegradable copolymers: in vitro hydrolytic degradation behaviors of photocured films of coumarin-endcapped poly(epsilon-caprolactone-co-trimethylene carbonate).

Coumarin-endcapped tetrabranched liquid copolymers composed of epsilon-caprolactone and trimethylene carbonate (TMC), prepared using pentaerythritol or four-branched poly(ethylene glycol) (PEG) as an initiator, were ultraviolet irradiated to produce photocured solid biodegradable copolymers. The hydrolytic degradation behaviors of photocured films were determined from the weight loss of the films. The initial hydrolysis rate (determined for up to 24 h using a quartz crystal microbalance) was enhanced with aqueous solutions of higher pH. The hydrolysis rate in the early period of immersion was increased with an increase in TMC content, whereas that in the later period (week order) decreased with a increase in TMC content. This inverse relation of composition dependence on the hydrolysis rate between the early and late periods was discussed. Topological measurements using scanning electron microscopy and atomic force microscopy as well as depth profiles of the fluorescein-stained hydrolyzed layer showed that for the pentaerythritol-initiated copolymer, irrespective of copolymer composition, hydrolysis occurred at surface regions and surface erosion proceeded with immersion time. For PEG-based copolymers, both surface erosion and bulk degradation occurred simultaneously. The hydrolyzed surfaces became highly wettable with water and exhibited noncell adhesivity.

Adhesives↗

Liquid, phenylazide-end-capped copolymers of epsilon-caprolactone and trimethylene carbonate: preparation, photocuring characteristics, and surface layering.

Photoreactive phenylazide-end-capped liquid copolymers were prepared by ring-opening copolymerization of epsilon-caprolactone (CL) and trimethylene carbonate (TMC) at an equimolar monomer feed ratio in the presence of a polyol, namely, a low-molecular-weight alcohol (di-, tri-, and tetraol) or poly(ethylene glycol) (PEG) as an initiator and tin(II) 2-ethylhexanoate as a catalyst, followed subsequently by phenylazide derivatization at their hydroxyl terminus. These tri- and tetrabranched liquid copolymers (precursors) with a molecular weight from approximately 2500 to 7000 g/mol were cross-linked to yield insoluble solids by ultraviolet (UV) light irradiation. The photocuring rate increased with increasing functionality of phenylazide and UV intensity and decreasing thickness of the liquid film of precursors. The photo-cross-linkability of phenylazide-derivatized liquid copolymers was found to be higher than that of the corresponding coumarin-derivatized liquid copolymers. Poly(lactide) (PLA) films surface-layered with photocured copolymers were prepared by coating surfaces with phenylazide-derivatized copolymers and their subsequent photoirradiation. Endothelial cells adhered well on the nontreated PLA and low-molecular-weight alcohol-based copolymer-layered and photocured films. Little cell adhesion was observed on the hydrolytically surface-eroded PLA film and the PEG-based copolymer-layered film. When a phenylazide-derivatized hexapeptide with the cell-adhesion tripeptidyl sequence, Arg-Gly-Asp (RGD), common to cell adhesive proteins, was photoimmobilized on these surfaces, the surfaces became cell adhesive. Microarchitectured surfaces, which were prepared by sequential procedures of surface coating and photocuring using a photomask with lattice windows, produced regionally differentiated cell adhesiveness.

Animals↗

Preparation of vinylated polysaccharides and photofabrication of tubular scaffolds as potential use in tissue engineering.

Polysaccharides, such as heparin, hyaluronan, and chitosan, were partially derivatized with a styryl or a methacryloyl group by condensation at a carboxyl or an amino group of the polysaccharides with 4-vinylaniline or 4-vinylbenzoic acid. The degree of substitution depended on the reaction conditions. These compounds with low degrees of derivatization produced water-swollen hydrogels only at relatively high concentrations (30-40 wt %) in the presence of a carboxylated camphorquinone upon visible light irradiation. A high degree of derivatization of heparin increased the gel yield and concomitantly reduced the degree of swelling. The copolymerization of these vinylated polysaccharides with styrenated gelatin considerably reduced the degree of swelling. Tubular photoconstructs were prepared by photocopolymerization of vinylated polysaccharide and vinylated gelatin. The mixing of diacrylated poly(ethylene glycol) with vinylated polysaccharide improved the burst strength of photogels against the gradual infusion of water. These photocurable polysaccharides may be used as photocured scaffolds in tissue-engineered devices.

Biocompatible Materials↗