Quantitative mapping of basal and vasareactive cerebral blood flow using split-dose 123I-iodoamphetamine and single photon emission computed tomography.

A new method has been developed for diffusible tracers, to quantify CBF at rest and after pharmacological stress from a single session of dynamic scans with dual bolus administration of a radiotracer. The calculation process consisted of three steps, including the procedures of incorporating background radioactivity contaminated from the previous scan. Feasibility of this approach was tested on clinical SPECT studies on 16 subjects. Two sequential SPECT scans, 30 min apart, were carried out on each subject, after each of two split-dose administrations of 111 MBq IMP. Of these, 11 subjects received acetazolamide at 10 min before the second IMP injection. Additional PET scans were also carried out on 6 subjects on a separate day, at rest and after acetazolamide administration. The other 5 subjects were scanned only at rest during the whole study period. Quantitative CBF obtained by this method was in a good agreement with those determined with PET (y(ml/100 g/min)=1.07x(ml/100 g/min)-1.14, r=0.94). Vasareactivity was approximately 40% over the whole cerebral area on healthy controls, which was consistent with a literature value. Reproducibility of CBF determined in the rest-rest study was 1.5+/-5.7%. Noise enhancement of CBF images, particularly the second CBF, was reduced, providing reasonable image quality. Repeat assessment of quantitative CBF from a single session of scans with split-dose IMP is accurate, and may be applied to clinical research for assessing vascular reactivity in patients with chronic cerebral vascular disease.

Aged↗

[Usefulness of attenuation correction with transmission source in myocardial SPECT].

Attenuation correction in SPECT has been used for uniformly absorptive objects like the head. On the other hand, it has seldom been applied to nonuniform absorptive objects like the heart and surrounding lungs because of the difficulty and inaccuracy of data processing. However, since attenuation correction using a transmission source recently became practical, we were able to apply this method to a nonuniform absorptive object. Therefore, we evaluated the usefulness of this attenuation correction system with a transmission source in myocardial SPECT. The dose linearity, defect/normal ratio using a myocardial phantom, and myocardial count distribution in clinical cases was examined with and without the attenuation correction system. We found that all data processed with attenuation correction were better than those without attenuation correction. For example, in myocardial count distribution, while there was a difference between men and women without attenuation correction, which was considered to be caused by differences in body shape, after processing with attenuation correction, myocardial count distribution was almost the same in all cases. In conclusion, these results suggested that attenuation correction with a transmission source was useful in myocardial SPECT.

Aged↗

[Application of phase contrast imaging to mammography].

Phase contrast images were obtained experimentally by using a customized mammography unit with a nominal focal spot size of 100 microm and variable source-to-image distances of up to 1.5 m. The purpose of this study was to examine the applicability and potential usefulness of phase contrast imaging for mammography. A mammography phantom (ACR156 RMI phantom) was imaged, and its visibility was examined. The optical density of the phantom images was adjusted to approximately 1.3 for both the contact and phase contrast images. Forty-one observers (18 medical doctors and 23 radiological technologists) participated in visual evaluation of the images. Results showed that, in comparison with the images of contact mammography, the phantom images of phase contrast imaging demonstrated statistically significantly superior visibility for fibers, clustered micro-calcifications, and masses. Therefore, phase contrast imaging obtained by using the customized mammography unit would be useful for improving diagnostic accuracy in mammography.

Humans↗

Evaluation of edge effect due to phase contrast imaging for mammography.

It is well-known that the edge effect produced by phase contrast imaging results in the edge enhancement of x-ray images and thereby sharpens those images. It has recently been reported that phase contrast imaging using practical x-ray tubes with small focal spots has improved image sharpness as observed in the phase contrast imaging with x-ray from synchrotron radiation or micro-focus x-ray tubes. In this study, we conducted the phase contrast imaging of a plastic fiber and plant seeds using a customized mammography equipment with a 0.1 mm focal spot, and the improvement of image sharpness was evaluated in terms of spatial frequency response of the images. We observed that the image contrast of the plastic fiber was increased by edge enhancement, and, as predicted elsewhere, spectral analysis revealed that as the spatial frequencies of the x-ray images increased, so did the sharpness gained through phase contrast imaging. Thus, phase contrast imaging using a practical molybdenum anode tube with a 0.1 mm-focal spot would benefit mammography, in which the morphological detectability of small species such as microcalcifications is of great concern. And detectability of tumor-surrounded glandular tissues in dense breast would be also improved by the phase contrast imaging.

Algorithms↗

Estimation of contrast of refraction contrast imaging compared with absorption imaging-basic approach.

PURPOSE: We discuss the usefulness of the refraction contrast method using highly parallel X-rays as a new approach to minute lung cancer detection. The advantages of refraction contrast images are discussed in terms of contrast, and a comparison is made with absorption images. MATERIALS AND METHODS: We simulated refraction contrast imaging using globules with the density of water in air as models for minute lung cancer detection. The contrast intensified by bright and dark lines was compared on a globule with the contrast of absorption images. We adopted the Monte Carlo simulation to determine the strength of the profile curve of the photon counts at the detector. RESULTS: The obtained contrasts were more intense by two to three digits than those obtainable with the absorption contrast imaging method. CONCLUSION: The contrast in refraction contrast imaging was more intense than that obtainable with absorption contrast imaging. A two to three digit improvement in contrast means that it is possible to greatly reduce the exposure dose necessary for imaging. Therefore, it is expected to become possible to detect the interfaces of soft tissues, which are difficult to capture with conventional absorption imaging, at low dosages and high resolution.

Absorption↗

Ray tracing analysis of overlapping objects in refraction contrast imaging.

We simulated refraction contrast imaging in overlapping objects using the ray tracing method. The easiest case, in which two columnar objects (blood vessels) with a density of 1.0 [g/cm3], run at right angles in air, was calculated. For absorption, we performed simulation using the Snell law adapted to the object's boundary. A pair of bright and dark spot results from the interference of refracted X-rays where the blood vessels crossed. This has the possibility of increasing the visibility of the image.

Angiography↗

Superimposed display of coronary artery on gated myocardial perfusion scintigraphy.

UNLABELLED: Fusion of images of vascular anatomy and of myocardial perfusion images might be helpful for understanding the relationship between ischemia and the responsible vessels. The aim of this study was to develop a simple means of superimposing the images obtained from coronary angiography and gated myocardial perfusion SPECT. METHODS: Right and left oblique views from conventional coronary angiography and left ventriculography (LVG) were stored as 512 x 512 x 8-bit digital datasets and combined. We reconstructed images from routine gated myocardial perfusion imaging (MPI) by using (99m)Tc-tetrofosmin to match the oblique positions between the image from MPI and combined angiographic images. We then generated a 3-dimensional (3D) surface map by using the quantitative gated SPECT (QGS)/quantitative perfusion SPECT (QPS) program. Both the combined angiographic images and the 3D surface map were rescaled and unified by registering the internal landmarks between the 2 images. After subtraction of the LVG image, the coronary angiogram and the 3D surface map were fused into 1 image. All processes were performed with the QGS/QPS program and commercially available graphic software. We applied this method to datasets from a cardiac phantom and from several patients with coronary artery disease. RESULTS: In the phantom study, our technique could obtain a 3D surface map in which the oblique angle was identified as that of radiography and could realize image registration and superimposition of radiography on scintigraphy. The preliminary results from the patients indicated that the markedly stenotic vessels showed good coincidence with the regional myocardial perfusion abnormalities on the unified images. In addition, these images could show the relationship between the coronary artery and regional wall motion in the gated mode. CONCLUSION: We developed a simple method of superimposing the image of the coronary artery tree on images from gated MPI. The technique yielded useful information about myocardial perfusion and function as well as the supplying coronary artery.

Adolescent↗

[Measurement of left ventricular chamber and myocardial volume in hypertrophic cardiomyopathy patients by ECG-gated myocardial perfusion SPECT: application of a newly developed edge-detection algorithm].

Quantitative gated SPECT (QGS) software has been reported to demonstrate inaccurate edge detection in the left ventricular chamber in hypertrophic cardiomyopathy patients. In this study we developed a method to calculate left ventricular volume (LVV) and left myocardial volume (LMV) from gated SPECT data using a newly developed edge-detection algorithm, and we compared it with the QGS method of calculating LVV and LMV in a phantom study. Our method gave more accurate measurements LVV and LMV whereas the QGS method underestimated LMV. Compared with QGS LVV and LMV, our method yielded better results in the phantom study.

Algorithms↗