PubMed Health⌕ Search

Biomedical subjects

Thomas Jira

Publications and source records attributed to Thomas Jira.

8 recordsLinked to original sources

Effect of chaotropic mobile phase additives on retention behaviour of beta-blockers on various reversed-phase high-performance liquid chromatography columns.

In this study the effect of type and concentration of chaotropic counter anion in buffered mobile phase on retention behaviour of some beta-blockers was studied. Two types of anions (perchlorate, dihydrogen phosphate) were examined under different concentrations. Further different pH-values for each anion were used to investigate the effect of pH changes on chaotropic behaviour of these anions. The role of organic modifier (methanol, acetonitrile) type was also considered. All these parameters were studied for three different RP-columns (calixarene modified silica gel, monolithic RP-column and a conventional RP-column). The results indicate that all studied factors affected the chaotropic behaviour of the tested anions. Also the type of the used stationary phase has found to play an important role in retention behaviour of beta-blockers.

Adrenergic beta-Antagonists↗

Retention behaviour of beta-blockers in HPLC using a monolithic column.

The chromatographic behaviour of a new HPLC-stationary phase (Chromolith RP-18e) is described for separation of beta-blockers. The effects of the different chromatographic conditions (buffer system, pH value, content of organic modifier, injection volume and flow rate) on the separation behaviour were studied. At higher flow rates the peaks seemed to be more symmetrical than at lower flow rates. The use of buffer or salt in the mobile phase for this separation is found to be very essential and the counter-anion type of this buffer or salt significantly affected the retention behaviour of beta-blockers while the cation type did not play the same important role.

Adrenergic beta-Antagonists↗

Peak shape improvement of basic analytes in capillary liquid chromatography.

The analysis of bases is of special interest in pharmaceutical research because numerous active substances contain basic functional groups. Capillary and conventional size LC separations of drug substances spiked with potential impurities were compared. In the case of the nonpolar drug levonorgestrel equal separation efficiency was readily attained by both techniques. The peaks of basic substances, however, showed extensive tailing when separated by capillary LC. The peak deformation was attributable to interactions of the basic substances with the polar inner surface of the fused silica capillaries employed in capillary LC and does not appear with the steel tubing generally used in conventional size LC. This drawback of capillary LC was overcome by use of deactivated fused silica capillaries for column hardware and transfer lines.

Amitriptyline↗

Evaluation of packed capillary liquid chromatography columns and comparison with conventional-size columns.

Apart from extracolumn effects peak dispersion in liquid chromatographic columns is caused by the column inlet, the packed bed, and the column outlet. A strategy applicable for independent evaluation of the individual sources of column band broadening was developed on the basis of the linear extrapolation method (LEM). This method was applied to compare the performance of packed capillary LC columns from various commercial suppliers with conventional-size columns. The columns differed widely in their performance with respect to peak shapes and widths for standard substances. The capillary columns were found well packed, but in some cases overall performance would benefit from improving the design of the area between the packed bed and the connecting capillaries, containing frits as well as dead volumes.

Chromatography, Liquid↗

Characterization of calixarene- and resorcinarene-bonded stationary phases. I. Hydrophobic interactions.

New HPLC phases with supramolecular selectors on the basis of calixarenes and resorcinarenes were investigated for the first time by means of empirically based test mixtures. The tests, originally developed for common reversed phases, were chosen to evaluate fundamental chromatographic properties of the new materials. In the first part of these studies three descriptors (hydrophobic retention capacity--k'(hyd), hydrophobic selectivity--alpha(hyd), steric selectivity--alpha(ster)) were determined. Except of higher alpha(ster) values and alpha(hyd) values with some methods for the resorcinarene phase the phases with supramolecular selectors were classified as less hydrophobic possessing lower hydrophobic and steric selectivities compared to three RP-C18 phases and a p-tert-butyl phenyl ether phase. The results were confirmed by means of a separation of geometric isomers of thioxanthenes. In contrast, in spite of lower k'(hyd) and alpha(hyd) values calixarene phases were more selective than the Kromasil-C18 phase in the separation of gestagenic and androgenic steroids due to specific interactions with the steroids of similar lipophilicity.

Calixarenes↗

Extracolumn band broadening in capillary liquid chromatography.

A commercially available capillary LC instrument was modified to investigate and control the contribution of different instrument components on extracolumn band broadening. Quantitative estimations of dispersion induced by several equipmental parts were carried out. Injection parameters could be optimized to achieve the theoretical value of 12 for a profile factor describing a rectangular sample profile. Additionally, an additive injector flow channel dependent dispersion effect was found. A practical approach for minimizing instrumental effects in capillary LC is suggested. The results were compared with those obtained with an HPLC instrument designed for conventional size columns.

Chromatography, Liquid↗

Separation of (Z)- and (E)-isomers of thioxanthene and dibenz[b,e]oxepin derivatives with calixarenes and resorcinarenes as additives in nonaqueous capillary electrophoresis.

Five acidic calix[4]arenes with carboxylic or sulfonic groups at either the upper or lower rim of the cavity and one resorc[4]arene were investigated to separate three thioxanthenes (flupentixol, clopenthixol, chlorprothixene) and a dibenz[b,e]oxepin derivative (doxepin) with cis-/trans-isomerism by nonaqueous capillary electrophoresis (NACE). Partial filling of the capillary with the UV-absorbing selectors led to a low detection limit and an advantageous signal-to-noise ratio (S/N). A sufficient electrophoretic mobility of the calixarenes towards the anode was necessary to outweigh the oppositely directed electroosmotic flow (EOF). This depended from the functional groups, the dissociation and the hydrodynamic radius of the cyclophanes. In contrast, the resorcinarene was useable only by addition of sodium dodecyl sulfate (SDS) because only the complex of the two selectors had an anodic apparent electrophoretic mobility. p-Sulfonyl-calix[4]arene (ss-a1) was the most capable selector for all E/Z-isomers with maximal alpha-values ranging from 1.056 for doxepin to 1.224 for chlorprothixene. This was due to the sufficient migration in reversed direction to the EOF even at low pH* values of 3.0. Otherwise, electrostatic as well as hydrophobic interactions with the positively charged isomers seem to contribute to a superior recognition. Increasing the concentration up to 15 mM ss-a1 and using acidic media (pH* 5.0) led to high separation efficiency. Changing the organic solvent provides a powerful tool to improve selectivity with N,N-dimethylformamide-methanol (DMF-MeOH)-mixtures for thioxanthenes. Further electrophoretic parameters were optimized, such as the concentration of the electrolytes, the addition of SDS, the kind of electrolytes and the voltage. Distinct differences in selectivities were found between the derivatives with thioxanthene and dibenzo[b,e]oxepin ring system, respectively. Further, the different basic side chain was responsible for the different selectivity at higher pH* values. In contrast, the substitution at position 2 of the thioxanthenes played a secondary role. Based on the studies of single parameters a method for a simultaneous separation of the four pairs of isomers within 13 min was developed.

Calixarenes↗

Separation of cis- and trans-isomers of thioxanthene and dibenz[b,e]oxepin derivatives on calixarene- and resorcinarene-bonded high-performance liquid chromatography stationary phases.

The chromatographic behavior of six calix[n]arene phases (n=4, 6, 8) and one calix[4]resorcinarene phase is described for the separation of cis- and trans-isomers of three thioxanthene (flupentixol, clopenthixol, chlorprothixene) and one benz[b,e]oxepin derivative (doxepin). The influences of two different organic modifiers (MeOH, MeCN) for the separation of the isomers on every column are described. Different selectivities of the stationary phases exist as a function of the ring size of the calixarenes and their substitution at the "upper rim" with p-tert.-butyl groups. Furthermore, the influence of free phenol groups on the resorcinarene phase is discussed. Relations between structural elements of the analytes and the retention behavior on the stationary phases are found. The selectivity of the calixarene and resorcinarene stationary phases is compared with a RP-C18 phase containing the same base silica. Advantages of the resorcinarene as well as of the calixarene columns exist for the separation of cis- and trans-isomers of three compounds dependent from the substitution in position 2 of the thioxanthenes, respectively the kind of the basic side chain of all substances.

Calixarenes↗