PubMed Health⌕ Search

Biomedical subjects

Thomas Laurell

Publications and source records attributed to Thomas Laurell.

9 recordsLinked to original sources

On-line monitoring of airborne chemistry in levitated nanodroplets: in situ synthesis and application of SERS-active Ag-Sols for trace analysis by FT-Raman spectroscopy.

We report a new strategy for on-line monitoring of chemical reactions in ultrasonically levitated, nanoliter-sized droplets by Raman spectroscopy. A flow-through microdispenser connected to an automated flow injection system was used to dose picoliter droplets into the node of an ultrasonic trap. Taking advantage of the flow-through characteristics of the microdispenser and the versatility of the automated flow system, a well-defined sequence of reagents could be injected via the microdispenser into the levitated droplet placed in the focus of the collection optics of the Fourier transform Raman spectrometer. In that way, chemical reactions could be carried out and monitored on-line. The developed system was used for fast, reproducible, in situ synthesis of a highly active surface enhanced Raman scattering (SERS) sol resulting from the reduction of silver nitrate with hydroxylamine hydrochloride in basic conditions. With this chemical system, SERS substrate preparation could be achieved at room temperature and in short time. The in situ prepared silver sol was used for trace analysis of several organic test molecules that were injected into the levitated SERS-active droplet again using the microdispenser. The concentration dependence of the SERS spectra was studied using 9-aminoacridine, revealing that down to the femtogram region high-quality SERS spectra could be obtained. Additionally, SERS spectra of 6-mercaptopurine, thiamine, and acridine were recorded in the levitated drop as well.

Journal Article↗

Screening of nucleation conditions using levitated drops for protein crystallization.

The growth of suitable protein crystals is an essential step in the structure determination of a protein by X-ray crystallography. At present, crystals are mostly grown using trial-and-error procedures, and protocols that rapidly screen for the crystal nucleation step are rare. Presented here is an approach to minimize the consumption of precious protein material while searching for the nucleation conditions. Acoustically levitated drops of known protein concentration (0.25-1.5-microL volumes) are injected with crystallizing agents using piezoelectric flow-through dispensers (ejecting 50-100-pL droplets at 1-9000 droplets/s). A restricted number of crystallizing agents representing three classes are used: poly(ethylene glycol), salts, and the viscous alcohol 2-methyl 2,4-pentanediol. From a digitized picture of the levitated drop volume, calculations are performed giving the concentrations of all components in the drop at any time during a "precipitation experiment". Supersaturation is the prerequisite for crystal nucleation, and protein precipitation indicates high supersaturation. A light source illuminates the levitated drop, and protein precipitation is monitored using right-angle light scattering. On the basis of these intensity measurements and the volume determination, precipitation diagrams for each crystallizing agent are constructed that give the protein/crystallizing agent concentration boundaries between the minimum and the maximum detectable protein precipitation. Guided by the concentration values obtained from such plots, when approaching the supersaturation region, separate crystallization drops are mixed and allowed to equilibrate under paraffin oil. At conditions in which microcrystals can be observed, the nucleation tendency of the macromolecule is confirmed. Optimization of crystallization conditions can then follow. Proteins tested include alcohol dehydrogenase and D-serine dehydratase. Alcohol dehydrogenase, known to crystallize easily, was used to evaluate whether the ultrasonic field inhibits nucleation. Details are given for the screening procedure of D-serine dehydratase, an enzyme earlier found to be difficult to crystallize reproducibly. The time and material-saving qualities of this method are emphasized, since a range of conditions can quickly be screened using small amounts of protein to roughly determine solubility characteristics of a protein before crystallization trials are initiated.

Alcohol Dehydrogenase↗

Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection.

Silicon microchips with immobilized antibodies were used to develop microfluidic enzyme immunoassays using chemiluminescence detection and horseradish peroxidase (HRP) as the enzyme label. Polyclonal anti-atrazine antibodies were coupled to the silicon microchip surface with an overall dimension of 13.1 x 3.2 mm, comprising 42 porous flow channels of 235-microm depth and 25-microm width. Different immobilization protocols based on covalent or noncovalent modification of the silica surface with 3-aminopropyltriethoxysilane (APTES) or 3-glycidoxypropyltrimethoxysilane (GOPS), linear polyethylenimine (LPEI, MW 750,000), or branched polyethylenimine (BPEI, MW 25,000), followed by adsorption or covalent attachment of the antibody, were evaluated to reach the best reusability, stability, and sensitivity of the microfluidic enzyme immunoassay (microFEIA). Adsorption of antibodies on a LPEI-modified silica surface and covalent attachment to physically adsorbed BPEI lead to unstable antibody coatings. Covalent coupling of antibodies via glutaraldehyde (GA) to three different functionalized silica surfaces (APTES-GA, LPEI-GA, and GOPS-BPEI-GA) resulted in antibody coatings that could be completely regenerated using 0.4 M glycine/HCl, pH 2.2. The buffer composition was shown to have a dramatic effect on the assay stability, where the commonly used phosphate buffer saline was proved to be the least suitable choice. The best long-term stability was obtained for the LPEI-GA surface with no loss of antibody activity during one month. The detection limits in the microFEIA for the three different immuno surfaces were 45, 3.8, and 0.80 ng/L (209, 17.7, and 3.7 pM) for APTES-GA, LPEI-GA, and GOPS-BPEI-GA, respectively.

Antibodies↗

Miniaturisation is mandatory unravelling the human proteome.

An insight into the proteome status of today is presented, covering aspects of market values, new scientific literature sources, new technology initiatives and future developments. The authors give a personal view of the importance and the expected progress of microtechnology in proteome research. The background to some of the fundamental analytical technologies where for example, chromatography has played and still plays a major role in the protein research area is emphasized. From this field we are currently harvesting decades of fundamental research in separation science. For further progress in the chromatography field, downscaling has proven to be mandatory. Likewise, in the proteomics era ahead miniaturisation and microchip techniques are foreseen to play a fundamental role for finalising the human proteome, an essential milestone for elucidating disease pathophysiology.

Coated Materials, Biocompatible↗

On-chip microextraction for proteomic sample preparation of in-gel digests.

Despite the high sensitivity and relatively high tolerance for contaminants of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) there is often a need to purify and concentrate the sample solution, especially after in-gel digestion of proteins separated by two-dimensional gel electrophoresis (2-DE). A silicon microextraction chip (SMEC) for sample clean-up and trace enrichment of peptides was manufactured and investigated. The microchip structure was used to trap reversed-phase chromatography media (POROS R2 beads) that facilitates sample purification/enrichment of contaminated and dilute samples prior to the MALDI-TOF MS analysis. The validity of the SMEC sample preparation technique was successfully investigated by performing analysis on a 10 nM peptide mixture containing 2 m urea in 0.1 m phosphate-buffered saline with MALDI-TOF MS. It is demonstrated that the microchip sample clean-up and enrichment of peptides can facilitate identification of proteins from 2-DE separations. The microchip structure was also used to trap beads immobilized with trypsin, thereby effectively becoming a microreactor for enzymatic digestion of proteins. This microreactor was used to generate a peptide map from a 100 nM bovine serum albumin sample.

Electrophoresis, Gel, Two-Dimensional↗

Improved chip design for integrated solid-phase microextraction in on-line proteomic sample preparation.

A recently introduced silicon microextraction chip (SMEC), used for on-line proteomic sample preparation, has proved to facilitate the process of protein identification by sample clean up and enrichment of peptides. It is demonstrated that a novel grid-SMEC design improves the operating characteristics for solid-phase microextraction, by reducing dispersion effects and thereby improving the sample preparation conditions. The structures investigated in this paper are treated both numerically and experimentally. The numerical approach is based on finite element analysis of the microfluidic flow in the microchip. The analysis is accomplished by use of the computational fluid dynamics-module FLOTRAN in the ANSYS software package. The modeling and analysis of the previously reported weir-SMEC design indicates some severe drawbacks, that can be reduced by changing the microextraction chip geometry to the grid-SMEC design. The overall analytical performance was thereby improved and also verified by experimental work. Matrix-assisted laser desorption/ionization mass spectra of model peptides extracted from both the weir-SMEC and the new grid-SMEC support the numerical analysis results. Further use of numerical modeling and analysis of the SMEC structures is also discussed and suggested in this work.

Miniaturization↗

Ready-made matrix-assisted laser desorption/ionization target plates coated with thin matrix layer for automated sample deposition in high-density array format.

The methodology for ready-made matrix-assisted laser desorption/ionization (MALDI) target plates covered with an optimized thin layer consisting of matrix and nitrocellulose has been developed. Piezoelectric microdispensing enabled sample depositions in a high-density array format of 2000 sample depositions on a conventionally sized target plate (45 x 47 mm). The sample depositions were made reproducibly in a fully automated mode by using an in-house developed computer-controlled piezoelectric flow-through microdispenser. Additionally, the piezoelectric technique facilitated significant analyte enrichment that increased the detection sensitivity. The MS signal was obtained rapidly, generally within ten laser pulses. An airbrush device was used to generate a fine spray of matrix and nitrocellulose dissolved in acetone. The acetone evaporated instantly when reaching the target plate leaving the entire surface with a thin and uniform matrix/nitrocellulose coating consisting of very small crystals of matrix embedded in the nitrocellulose. These crystals acted as a seed-layer on subsequent analyte depositions, rendering homogeneous sample spots when using alpha-cyano-4-hydroxycinnamic acid (CHCA) as matrix. The relative standard deviation of the signal intensity between spots was (20-30)% (n = 30). The detection sensitivity was improved by restricting the sample spot diameter to 300 microm. The spot size was affected by the deposition rate and the evaporation rate of the dispensed sample volume. Mass spectra of a 25-amol peptide mixture deposition were successfully recorded.

Journal Article↗

Tissue reactions evoked by porous and plane surfaces made out of silicon and titanium.

Square-shaped silicon or titanium implants with plane or porous surfaces surrounded by a rim of silicone were implanted in the rat abdominal wall for evaluation of the tissue response after one, six, or 12 weeks. Cell damage was identified as increased membrane permeability using fluorescence microscopy by injection of propidium iodide prior to the killing of the rats. Capsule thickness and immunohistochemical quantification of macrophages were used as a further measure of the foreign-body reaction. There were no significant differences in capsular cell densities for macrophages, total cells (macrophages, fibroblasts, and other cells), or necrotic cells at the different time points for the four surfaces studied. However, significant differences in the kinetics of the response were found between plane surfaces compared with porous ones. Both types of plane surfaces developed a significant increase in capsule thickness over time in contrast to the porous implants. Porous silicon displayed a significant decrease in total cells in the reactive capsule over time. Furthermore, porous silicon and titanium surfaces displayed a significant decrease in total cell numbers at the implant interface between six and 12 weeks. The present study demonstrated that implanted silicon elicited soft-tissue reactions comparable to that of titanium.

Abdominal Muscles↗