Containerless reaction monitoring in ionic liquids by means of Raman microspectroscopy.

Reaction monitoring by Raman microspectroscopy in levitated room temperature ionic liquid (RTIL) droplets is reported. Due to their non-volatility, RTIL droplets are well-suited to act as wall-less microreactors. The droplets were produced by a piezoelectric flow-through microdispenser connected to an automated flow injection system and were levitated by an acoustic trap. Taking advantage of the flow system versatility, the sequence of reagents was easily changed to study a model organic reaction: the Knoevenagel condensation. The reaction was followed by Raman microspectrometry and the obtained spectra were analysed using multivariate curve resolution to retrieve the concentration profiles and pure spectra of reactants, intermediates and products involved in the reaction. In addition, information about solvation interactions was obtained by monitoring the desolvation process taking place when a volatile co-solvent evaporated from the droplet.

Journal Article↗

2DDB - a bioinformatics solution for analysis of quantitative proteomics data.

BACKGROUND: We present 2DDB, a bioinformatics solution for storage, integration and analysis of quantitative proteomics data. As the data complexity and the rate with which it is produced increases in the proteomics field, the need for flexible analysis software increases. RESULTS: 2DDB is based on a core data model describing fundamentals such as experiment description and identified proteins. The extended data models are built on top of the core data model to capture more specific aspects of the data. A number of public databases and bioinformatical tools have been integrated giving the user access to large amounts of relevant data. A statistical and graphical package, R, is used for statistical and graphical analysis. The current implementation handles quantitative data from 2D gel electrophoresis and multidimensional liquid chromatography/mass spectrometry experiments. CONCLUSION: The software has successfully been employed in a number of projects ranging from quantitative liquid-chromatography-mass spectrometry based analysis of transforming growth factor-beta stimulated fi-broblasts to 2D gel electrophoresis/mass spectrometry analysis of biopsies from human cervix. The software is available for download at SourceForge.

Computational Biology↗

High-speed biomarker identification utilizing porous silicon nanovial arrays and MALDI-TOF mass spectrometry.

Speed and accuracy are crucial prerequisites in the application of proteomic methods to clinical medicine. We describe a microfluidic-based nanovial array for rapid proteolytic processing linked to MALDI-TOF MS. This microscale format consumes only minute amounts of sample, and it is compatible with rapid bioanalytical protocols and high-sensitivity readouts. Arrays of vials (300 microm in diameter and 25 microm deep), isotropically etched in silicon wafers were electrochemically porosified. Automated picoliter microdispensing was employed for precise fluid handling in the microarray format. Vials were prefilled with trypsin solution, which was allowed to dry. Porosified and nonporosified nanovials were compared for trypsin digestion and subsequent MS identification of three model proteins: lysozyme, alcohol dehydrogenase, and serum albumin at levels of 100 and 20 fmol. In an effort to assess the rapid digestion platform in a context of putative clinical applications, two prostate cancer biomarkers, prostate-specific antigen (PSA) and human glandular kallikrein 2 (hK2), were digested at levels of 100 fmol (PSA), 20 fmol (PSA) and 8 fmol (hK2). All biomarker digestions were completed in less than 30 s, with successful MS identification in the porous nanovial setting.

Alcohol Dehydrogenase↗

Miniaturized solid-phase extraction and sample preparation for MALDI MS using a microfabricated integrated selective enrichment target.

A microfabricated proteomic sample preparation and sample presentation device, Integrated Selective Enrichment Target, (ISET), comprising an array of 96 perforated nanovials is described. Each perforated nanovial can be filled with solid-phase extraction media for purification and concentration of peptides prior to matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). The validity of the ISET sample preparation is shown by analysis of low nM-pM standard samples, as well as biological samples. The ISET solid-phase extraction sample preparation was compared to ZipTip and MassPREP PROtarget sample preparation, demonstrating a superior performance with respect to number of detected peptides and signal intensity of detected peptides.

Caseins↗

Flow-through microdispenser for interfacing micro-HPLC to Raman and mid-IR spectroscopic detection.

A flow-through microdispenser has been coupled to a micro HPLC separation system and used as a solvent elimination interface for Fourier transform infrared (FTIR) and Raman spectroscopic detection of the separated compounds. Using the microdispenser picoliter sized droplets can be generated and deposited on an appropriate target placed on a computerized x, y-stage. Evaporation of volatile solvent and buffer is rapid and allows analysis of the obtained dry deposits by various techniques. Due to the destruction free character of Raman and FTIR spectroscopy they can be applied sequentially to interrogate the same deposit. In the reported application five phenolic acids typically present in wine have been separated on a C-18 column technique using a mixture of water, methanol and acetic acid as mobile phase. For spectrum acquisition infrared and Raman microscopes have been used. The spectra recorded from the dried deposits of the separated compounds agreed well with the reference spectra of corresponding components.

Chromatography, High Pressure Liquid↗

Biocompatibility of surfaces for antibody microarrays: design of macroporous silicon substrates.

Major efforts to develop antibody microarray technology to enable global proteome analysis to be performed in a facile manner are under way. In this process, the design and the properties of the substrate will play crucial roles. In the present study, we have developed novel, highly biocompatible solid supports for microarrays, using adsorbed recombinant human single-framework antibody fragments as probes. Several silicon-based supports, including planar silicon, micro- and macroporous silicon, and nitrocellulose-coated variants thereof, were designed and evaluated in a stepwise procedure. The surfaces were scored based on biocompatibility and probe binding capacity as judged by spot morphology, signal intensities, signal to noise ratios, dynamic range, sensitivity, and reproducibility. A set of five commercially available substrates, selected to represent a set of supports providing different surface and coupling chemistries, was used as reference surfaces. The results showed that several well-performing silicon-based supports could be designed; in particular, a nitrocellulose-coated macroporous variant, MAP3-NC7, received the highest scores. In comparison, MAP3-NC7 displayed properties equal to or better than those of the reference substrates. Taken together, designed surfaces based on silicon can undoubtedly meet the requirements of the next generation of solid supports for antibody microarrays.

Antibodies↗

Microchip immobilized enzyme reactors for hydrolysis of methyl cellulose.

Microchip immobilized enzyme reactors (microIMERs) with immobilized endoglucanases were applied for the hydrolysis of methyl cellulose (MC). MCs of various molecular weights were hydrolyzed using two microIMERs containing immobilized celloendoglucanase Cel 5A from Bacillus agaradhaerens (BaCel 5A) connected in series. Hydrolysis by the microIMER could be confirmed from the average molar masses and molar mass distributions measured by size exclusion chromatography (SEC) with online multiangle light scattering and refractive index detection. Methylated cellooligosaccharides with degrees of polymerization (DP) between 1 and 6 formed during hydrolysis were analyzed by direct infusion electrospray ionization ion-trap mass spectrometry (ESI-ITMS). Mass spectra of microIMER- and batch-hydrolyzed samples were compared and no significant differences were found, indicating that microIMER hydrolysis was as efficient as conventional batch hydrolysis. A fast and automated hydrolysis with online MS detection was achieved by connecting the microIMER to high-performance liquid chromatography and ESI-ITMS. This online separation reduced the relative intensities of interfering signals and increased the signal-to-noise ratios in MS. The microIMER hydrolysates were also subjected to SEC interfaced with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. With this technique, oligomers with DP 3-30 could be detected. The hydrolysis by the microIMER was performed within 60 min, i.e. significantly faster compared with batch hydrolysis usually performed for at least 24 h. The microIMER also allowed hydrolysis after 10 days of continuous use. The method presented in this work offers new approaches for the analysis of derivatized cellulose and provides the possibility of convenient online, fast, and more versatile analysis compared with the traditional batch method.

Bacillus↗

Carrier medium exchange through ultrasonic particle switching in microfluidic channels.

This paper describes a method, utilizing acoustic force manipulation of suspended particles, in which particles in a laminar flow microchannel are continuously translated from one medium to another with virtually no mixing of the two media. During the study, 5-microm polyamide spheres suspended in distilled water, spiked (contaminated) with Evans blue, were switched over to clean distilled water. More than 95% of the polyamide spheres could be collected in the clean medium while removing up to 95% of the contaminant. Preliminary experiments to use this method to wash blood were performed. Red blood cells were switched from blood, spiked with Evans blue, to clean blood plasma. At least 95% of the red blood cells (bovine blood) could be collected in clean blood plasma while up to 98% of the contaminant was removed. The obtained results indicate that the presented method can be used as a generic method for particle washing and, more specifically, be applied for both intraoperative and postoperative blood washing.

Journal Article↗

Particle separation using ultrasound can be used with human shed mediastinal blood.

BACKGROUND: Shed mediastinal blood collected by cardiotomy suction has been shown to be a large contributor to lipid microemboli ending up in different organs. The aim of this study was to test the separation efficiency on human shed blood of a new separation method developed to meet this demand. METHODS: Shed mediastinal blood collected from the pericardial cavity of 13 patients undergoing cardiac surgery with cardiopulmonary bypass was collected. The blood was processed in an eight-channel parallel PARSUS separator, and separation efficiency was determined. RESULTS: Erythrocyte recovery, in terms of a separation ratio, varied between 68% and 91%. Minor electrolyte changes took place, where levels of sodium increased and levels of potassium and calcium decreased. CONCLUSION: This study demonstrates that PARSUS technology can be used on human shed mediastinal blood with good separation efficiency. The technology is, thereby, suggested to have future clinical relevance.

Blood Transfusion, Autologous↗

Trapping of microparticles in the near field of an ultrasonic transducer.

We are investigating means of handling microparticles in microfluidic systems, in particular localized acoustic trapping of microparticles in a flow-through device. Standing ultrasonic waves were generated across a microfluidic channel by ultrasonic microtransducers integrated in one of the channel walls. Particles in a fluid passing a transducer were drawn to pressure minima in the acoustic field, thereby being trapped and confined at the lateral position of the transducer. The spatial distribution of trapped particles was evaluated and compared with calculated acoustic intensity distributions. The particle trapping was found to be strongly affected by near field pressure variations due to diffraction effects associated with the finite sized transducer element. Since laterally confining radiation forces are proportional to gradients in the acoustic energy density, these near field pressure variations may be used to get strong trapping forces, thus increasing the lateral trapping efficiency of the device. In the experiments, particles were successfully trapped in linear fluid flow rates up to 1mm/s. It is anticipated that acoustic trapping using integrated transducers can be exploited in miniaturised total chemical analysis systems (microTAS), where e.g. microbeads with immobilised antibodies can be trapped in arrays and subjected to minute amounts of sample followed by a reaction, detected using fluorescence.

Journal Article↗

Microfluidic biosensing systems. Part I. Development and optimisation of enzymatic chemiluminescent micro-biosensors based on silicon microchips.

Chemiluminescent (CL) enzyme-based flow-through microchip biosensors (micro-biosensors) for detection of glucose and ethanol were developed for the purpose of monitoring real-time production and release of glucose and ethanol from microchip immobilised yeast cells. Part I of this study focuses on the development and optimisation of the micro-biosensors in a microfluidic sequential injection analysis (microSIA) system. Glucose oxidase (GOX) or alcohol oxidase (AOX) was co-immobilised with horseradish peroxidase (HRP) on porous silicon flow through microchips. The hydrogen peroxide produced from oxidation of the corresponding analyte (glucose or ethanol) took part in the chemiluminescent (CL) oxidation of luminol catalysed by HRP enhanced by addition of p-iodophenol (PIP). All steps in the microSIA system, including control of syringe pump, multiposition valve (MPV) and data readout, were computer controlled. The influence of flow rate and luminol- and PIP concentration were investigated using a 2(3)-factor experiment using the GOX-HRP sensor. It was found that all estimated single factors and the highest order of interaction were significant. The optimum was found at 250 microM luminol and 150 microM PIP at a flow rate of 18 microl min(-1), the latter as a compromise between signal intensity and analysis time. Using the optimised system settings one sample was processed within 5 min. Two different immobilisation chemistries were investigated for both micro-biosensors based on 3-aminopropyltriethoxsilane (APTS)- or polyethylenimine (PEI) functionalisation followed by glutaraldehyde (GA) activation. GOX-HRP micro-biosensors responded linear in a log-log format within the range 10-1000 microM glucose. Both had an operational stability of at least 8 days, but the PEI-GOX-HRP sensor was more sensitive. The AOX-HRP micro-biosensors responded linear (log-log) in the range between 1 and 10 mM ethanol, but the PEI-AOX-HRP sensor was in general more sensitive. Both sensors had an operational stability of at least 8 h, but with a half-life of 2-3 days.

Biosensing Techniques↗

Microfluidic biosensing systems. Part II. Monitoring the dynamic production of glucose and ethanol from microchip-immobilised yeast cells using enzymatic chemiluminescent micro-biosensors.

A microfluidic flow injection (microFIA) system was employed for handling and monitoring of cell-released products from living cells immobilised on silicon microchips. The dynamic release of glucose and ethanol produced from sucrose by immobilised Saccharomyces cerevisiae cells was determined using microchip biosensors (micro-biosensors) with either co-immobilised glucose oxidase-horseradish peroxidase (GOX-HRP), or alcohol oxidase-horseradish peroxidase (AOX-HRP), catalysing a series of reactions ending up with chemiluminescence (CL) generated from HRP-catalysed oxidation of luminol in presence of p-iodophenol (PIP). The yeast cells were attached by first treating them with polyethylenimine (PEI) followed by adsorption to the microchip surface. The cell loss during assaying was evaluated qualitatively using scanning electron microscopy (SEM), showing that no cells were lost after 35 min liquid handling of the cell chip at 10 microl min(-1). The enzymes were immobilised on microchips via PEI-treatment followed by glutaraldehyde (GA) activation. The GOX-HRP micro-biosensors could be used during five days without any noticeable decrease in response, while the AOX-HRP micro-biosensors showed continuously decreasing activity, but could still be used employing calibration correction. The glucose and ethanol released from the immobilised yeast chips were quantitatively monitored, by varying the incubation time with sucrose, showing the possibilities and advantages of using a microfluidic system set-up for cell-based assays.

Biosensing Techniques↗

Separation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels.

A method to continuously separate different particle types in a suspension is reported. Acoustic forces in a standing wave field were utilized to discriminate lipid particles from erythrocytes in whole blood. The presented technology proposes a new method of cleaning, i.e. removing lipid emboli from, shed blood recovered during cardiac surgery. Blood contaminated with lipid particles enter a laminar flow micro channel. Erythrocytes and lipid particles suspended in blood plasma are exposed to a half wavelength standing wave field orthogonal to the direction of flow as they pass through the channel. Because of differences in compressibility and density the two particle types move in different directions, the erythrocytes towards the centre of the channel and the lipid particles towards the side walls. The end of the channel is split into three outlet channels conducting the erythrocytes to the centre outlet and the lipid particles to the side outlets due to the laminar flow profile. The separation channel was evaluated in vitro using polyamide spheres suspended in water, showing separation efficiencies approaching 100%. The system was also evaluated on whole blood using tritium labelled lipid particles added to bovine blood. More than 80% of the lipid particles could be removed while approximately 70% of the erythrocytes were collected in one third of the original fluid volume. The study showed that the further reduced micro channel dimensions provided improved performance with respect to; (i) separation efficiency, (ii) actuation voltage, and (iii) volumetric throughput as compared to earlier work.

Acoustics↗

Developments toward a microfluidic system for long-term monitoring of dynamic cellular events in immobilized human cells.

A microfluidic system for long-term real-time monitoring of dynamic cellular events of immobilized human cells was investigated. The luciferase reporter gene activity in the reporter cell line HFF11, based on HeLa cells, was used as the model system. The cells were immobilized on silicon flow-through microchips and continuously supplied with a cell medium at 2 microL/min while maintaining the chip at 37 degrees C. The HFF11 cell line was designed for high-throughput screening of ligands for seven-transmembrane receptors. When a ligand binds, the receptor is activated and a cascade of intracellular reactions starts, ending with the synthesis of the reporter protein Photinus luciferase. The major goal was to develop a microfluidic system for continuous long-term assaying of the intracellular reporter gene activity in real time and determine the conditions, which could minimize cells stress and hence unspecific expression of the reporter gene. In the resulting microfluidic system and assay protocol, the cell microchip could be kept and assayed for a period up to 30 h. The developed system and data outcome was compared with a corresponding microtiter plate performed with the same cell line to highlight the advantages obtained in the microfluidic format.

Animals↗

Acoustic control of suspended particles in micro fluidic chips.

A method to separate suspended particles from their medium in a continuous mode at microchip level is described. The method combines an ultrasonic standing wave field with the extreme laminar flow properties obtained in a silicon micro channel. The channel was 750 microm wide and 250 microm deep with vertical side walls defined by anisotropic wet etching. The suspension comprised "Orgasol 5 microm" polyamide spheres and distilled water. The channel was perfused by applying an under pressure (suction) to the outlets. The channel was ultrasonically actuated from the back side of the chip by a piezoceramic plate. When operating the acoustic separator at the fundamental resonance frequency the acoustic forces were not strong enough to focus the particles into a well defined single band in the centre of the channel. The frequency was therefore changed to about 2 MHz, the first harmonic with two pressure nodes in the standing wave, and consequently two lines of particles were formed which were collected via the side outlets. Two different microchip separator designs were investigated with exit channels branching off from the separation channel at angles of 90 degrees and 45 degrees respectively. The 45 degrees separator displayed the most optimal fluid dynamic properties and 90% of the particles were gathered in 2/3 of the original fluid volume.

Acoustics↗

Integrated selective enrichment target--a microtechnology platform for matrix-assisted laser desorption/ionization-mass spectrometry applied on protein biomarkers in prostate diseases.

The performance of a miniaturized sample processing platform for matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS), manufactured by silicon microfabrication, called integrated selective enrichment target (ISET) technology was evaluated in a biological context. The ISET serves as both sample treatment device and MALDI-MS target, and contains an array of 96 perforated nanovials, which each can be filled with 40 nL of reversed-phase beads. This methodology minimizes the number of sample transfers and the total surface area available for undesired adsorption of the analytes in order to provide high-sensitivity analysis. ISET technology was successfully applied for characterization of proteins coisolated by affinity chromatography of prostate-specific antigen (PSA) from human seminal fluid. The application of ISET sample preparation enabled multiple analyses to be performed on a limited sample volume, which resulted in the discovery that prolactin inducible protein (PIP) was coisolated from the samples.

Biomarkers↗