Quantification of aortic valve stenosis in MRI-comparison of steady-state free precession and fast low-angle shot sequences.

We compared two different magnetic resonance (MR) sequences [steady-state free precession (SSFP) and gradient echo fast low-angle shot (FLASH)] for the assessment of aortic valve areas in aortic stenosis using transesophageal echocardiography (TEE) as the standard of reference. Thirty-two patients with known aortic stenosis underwent MR (1.5 T) using a cine SSFP sequence and a cine FLASH sequence. Planimetry was performed in cross-sectional images and compared to the results of the TEE. In seven patients the grade of stenosis was additionally assessed by invasive cardiac catheterization (ICC). The mean aortic valve area measured by TEE was 0.97+/-0.19 mm(2), 1.00+/-0.25 mm(2) for SSFP and 1.25+/-0.23 mm(2) based on FLASH images. The mean difference between the valve areas assessed based on SSFP and TEE images was 0.15+/-0.13 cm(2) (FLASH vs TEE: 0.29+/-0.17 cm(2)). Bland-Altman analysis demonstrated that measurements using FLASH images overestimated the aortic valve area compared to TEE. Comparing ICC with MRI and TEE, only a weak to moderate correlation was found (ICC vs TEE: R=0.52, p=0.22; ICC vs SSFP: R=0.20, p=0.65; ICC vs FLASH: R=0.16, p=0.70). Measurements of the aortic valve area based on SSFP images correlate better with TEE compared to FLASH images.

Aged↗

Magnetic resonance cardiac perfusion imaging-a clinical perspective.

Coronary artery disease (CAD) with its clinical appearance of stable or unstable angina and acute myocardial infarction is the leading cause of death in developed countries. In view of increasing costs and the rising number of CAD patients, there has been a major interest in reliable non-invasive imaging techniques to identify CAD in an early (i.e. asymptomatic) stage. Since myocardial perfusion deficits appear very early in the "ischemic cascade", a major breakthrough would be the non-invasive quantification of myocardial perfusion before functional impairment might be detected. Therefore, there is growing interest in other, target-organ-specific parameters, such as relative and absolute myocardial perfusion imaging. Magnetic resonance (MR) imaging has been proven to offer attractive concepts in this respect. However, some important difficulties have not been resolved so far, which still causes uncertainty and prevents the broad application of MR perfusion imaging in a clinical setting. This review explores recent technical developments in MR hardware, software and contrast agents, as well as their impact on the current and future clinical status of MR imaging of first-pass myocardial perfusion imaging.

Contrast Media↗

Using cardiac magnetic resonance tomography for assessment of aortic valve area in aortic valve stenosis.

Calcified aortic valve stenosis (AS) is the most common valvular disease in the elderly population and constitutes a significant health and socioeconomic problem. Doppler echocardiography is the recommended diagnostic tool for the initial evaluation of AS. Transvalvular pressure gradients and aortic valve area have been used as quantitative parameters for grading the severity of AS, but the latter one is less susceptible to changes in flow dynamics and therefore considered the more independent and reliable parameter. The aortic valve area can be assessed directly by transesophageal echocardiography (TEE), which reflects the anatomic or geometric orifice area, or it can be calculated noninvasively by transthoracic echocardiography (TTE) using the continuity equation, or, invasively, by cardiac catheterization (CC) using the Gorlin formula, both reflecting the effective orifice area. Assessment of aortic valve area by TTE can be limited in some patients due to inadequate acoustic window. Similarly, TEE as a semi-invasive technique is not well tolerated by some patients and the planimetry is limited in patients with heavily calcified aortic valve leaflets. CC is an invasive procedure associated with a substantial risk of cerebral embolism and the Gorlin formula has been shown to be susceptible to changes in flow dynamics. Cardiac magnetic resonance tomography (CMR) is a new imaging technique capable of imaging the aortic valve with high resolution and has recently been used for assessment of the aortic valve area in AS. This review focuses on the feasibility of CMR for the assessment of aortic valve area in AS compared to current standard techniques and discusses some of the typical pitfalls and the sources for the discrepant results observed between the different techniques for assessment of the aortic valve area.

Aortic Valve↗

Myocardial infarct: depiction with contrast-enhanced MR imaging--comparison of gadopentetate and gadobenate.

Institutional review board approval and patient written informed consent were obtained. On two separate occasions, 24 hours apart, contrast-enhanced cardiac magnetic resonance (MR) imaging was performed prospectively at 1, 3, 5, 10, and 20 minutes after injection of gadopentetate dimeglumine and gadobenate dimeglumine in 15 patients (11 men, four women) with history of myocardial infarction. Both agents allowed detection of infarcted myocardium. T1 values at all times were significantly (P < .05) lower for gadobenate, compared with values for gadopentetate, in both infarcted and noninfarcted myocardium. At 1 minute after administration of both agents, T1 values in left ventricular cavity (LVC) were not different; at 3-20 minutes after injection, values were significantly (P < .05) lower for gadobenate. Differences between contrast-to-noise ratio (CNR) values of infarcted and noninfarcted myocardium were significantly higher on gadobenate-enhanced images (P < .05). CNR values between infarcted myocardium and LVC were significantly higher on gadopentetate-enhanced images (P < .05). Gadopentetate might permit better delineation of infarcts, especially subendocardial infarcts.

Aged↗

Late enhancement: a new feature in MRI of arrhythmogenic right ventricular cardiomyopathy?

Aim of the study was to evaluate whether late enhancement (LE) in contrast-enhanced MRI can be used to characterize fibrofatty myocardial replacement in patients with arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC). Fifteen patients with suspected ARVC underwent CE-MRI using a 1.5 T scanner. Long and short axis SSFP cine images and T1-weighted fast spin echo images were collected in all patients. After injection of 0.2 mmol/kg Gd-DTPA (Magnevist, Schering, Berlin, Germany), inversion recovery gradient echo images were acquired in long and contiguous short axes to detect myocardial LE indicating areas of fibrous tissue within the myocardium. For definition of ARVC, the ESC Task force criteria were used. In 7 (47%) of 15 patients, ARVC was diagnosed based on the ESC criteria. In all of these 7 patients, MRI showed morphologic or functional criteria of ARVC according to the ESC. LE of the right ventricular myocardium was detected in 5 (71%) of the 7 ARVC patients, additional LE of the left ventricular myocardium in 2 of these patients. None of the 7 patients meeting the ARVC diagnostic criteria had fatty RV infiltration demonstrable by conventional T1-weighted imaging. Eight patients neither showed morphologic criteria of ARVC nor LE. In conclusion, late enhancement can be detected in the right and left ventricular myocardium in some ARVC patients. LE might represent intramyocardial areas of fibrous tissue.

Adult↗

Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation.

OBJECTIVE: The purpose of our study was to quantify left ventricular function and mass derived from retrospectively ECG-gated 16-MDCT coronary angiography data sets using a new analysis software based on automatic contour detection in comparison to corresponding standard of reference measurements acquired with MRI. SUBJECTS AND METHODS: Multiplanar reformations in the short-axis orientation were calculated from axial contrast-enhanced CT images in 18 patients (men, 15; women, three; age range, 38-70 years; mean, 57.4 +/- 10.2 [SD] years) who were referred for CT coronary angiography. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed with a recently developed imaging software using an automated contour detection algorithm of left ventricular endo- and epicardial contours and by manual tracing. The data were compared with similar measurements on MRI as the standard of reference. RESULTS: EDV, ESV, EF, and LVM derived from an automated contour detection algorithm were not statistically significantly different from manual tracing (CT(auto) vs CT(manual): EDV = 137.1 +/- 45.7 mL vs 134.2 +/- 39.9 mL, ESV = 58.8 +/- 34.2 mL vs 58.1 +/-30.1 mL, EF = 59.2% +/- 13.7% vs 58.1% +/- 12.0%, LVM = 130.9 +/- 29.1 g vs 133.7 +/- 33.2 g; p > 0.05). However, EDV (118.7 +/- 43.6 mL), ESV (50.1 +/- 33.5 mL), and LVM (142.8 +/-38.4 g) as calculated on MR data sets were statistically significantly different from those calculated on CT (p < 0.05), whereas MRI-based EF (59.9% +/- 14.4%) did not differ statistically significantly from those based on both CT algorithms (p > 0.05). CONCLUSION: Automatic and manual analysis of data acquired during CT coronary angiography using a 16-MDCT scanner allows a reliable assessment of left ventricular ejection fraction and a rough estimation of left ventricular volumes and mass.

Adult↗

Myocardial late enhancement in contrast-enhanced cardiac MRI: distinction between infarction scar and non-infarction-related disease.

OBJECTIVE: Our objective was to assess and compare the patterns of late enhancement (LE) in contrast-enhanced cardiac MRI caused by myocardial infarction and different myocardial diseases that are not related to ischemic infarction. MATERIALS AND METHODS: A total of 811 consecutive contrast-enhanced cardiac MRI studies performed for different indications were reviewed for left ventricular myocardial LE after gadopentetate dimeglumine administration. MRI studies were performed on a 1.5-T scanner using an inversion recovery turbo FLASH sequence (TR/TE, 8/4 msec; flip angle, 25 degrees). The LE pattern of ischemic infarction scar was compared with that in nonischemic myocardial disease. RESULTS: LE was found in 421 (52%) patients. In all patients with myocardial infarction, LE included the subendocardial layer. Nineteen patients without history of myocardial infarction and angiographically excluded coronary artery disease showed different patterns of LE caused by myocarditis, sarcoidosis, arrhythmogenic right ventricular dysplasia, cardiomyopathy, endomyocardial fibrosis, and iatrogenic scars after biopsy, ablation of septal hypertrophy, and myocardial laser revascularization. CONCLUSION: LE in contrast-enhanced cardiac MRI is not specific for ischemic infarction. LE in ischemic infarction always involves the subendocardial layer, whereas it does not necessarily do so in other myocardial diseases. Therefore, if LE omit the subendocardial layer, different nonischemic myocardial diseases have to be considered. The pattern of LE might be helpful for the differential diagnosis of myocardial disease and in distinguishing it from ischemic disease.

Adult↗

Coronary artery calcium score: influence of reconstruction interval at 16-detector row CT with retrospective electrocardiographic gating.

In 30 patients, Agatston and volumetric scores were assessed by using retrospectively gated multi-detector row computed tomography (CT). For each patient, 10 data sets were created at different times and were evenly spaced throughout the cardiac cycle. For each reconstruction, patients were assigned a percentile that described the level of cardiovascular risk. Nineteen (63%) of 30 patients could be assigned to more than one risk group depending on the reconstruction interval used. Agatston and volumetric scores both proved highly dependent on the reconstruction interval used (coefficient of variation, < or =63.1%) even with the most advanced CT scanners. Accurate and reproducible quantification of coronary calcium seems to require analysis of multiple reconstructions.

Adult↗

Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography.

OBJECTIVES: The aim of this study was to evaluate the diagnostic accuracy of a 16-detector row computed tomography (CT) scanner for the assessment of coronary artery bypass grafts. BACKGROUND: A new generation of multislice spiral CT scanners, equipped with more and thinner detector rows, allows for reliable noninvasive detection of obstructive coronary artery disease. METHODS: The study included 51 consecutive patients. Three patients had to be excluded from the study due to arrhythmias or fast heart rates despite beta-blockade. A total of 48 patients with 131 coronary artery bypass grafts (internal mammary artery, n = 40; venous grafts, n = 91) were examined by computed tomography angiography (CTA) and by invasive coronary angiography (ICA) using a 16-detector row CT scanner. For cardiac protocols, only the 12 inner detector rings are applied. All CT examinations were performed with retrospective electrocardiogram gating at a mean heart rate of 64 +/- 5 beats/min; 120 ml of Xenetix 300 (Guerbert GmbH, Sulzbach, Germany) were continuously injected. The bypass graft patency and the presence of stenoses as well as the proximal and distal anastomoses were evaluated by two experienced readers. RESULTS: All bypass grafts and 74% of the distal bypass anastomoses could be visualized by CTA; 21 bypass graft occlusions and 1 significant stenosis were detected by CTA and confirmed by ICA. Five false positive and one false negative finding resulted in a sensitivity of 96%, a specificity of 95%, a positive predictive value of 81%, and a negative predictive value of 99%. CONCLUSIONS: Sixteen-detector row CT scanner technology allows for the reliable visualization of coronary bypass grafts. Dysfunctional bypass grafts can be detected with high diagnostic accuracy. This technology can be used as a noninvasive test for patients with suspected graft dysfunction.

Aged↗

Echoscintigraphy: a new imaging modality for the reduction of color blooming and acoustic shadowing in contrast sonography.

The purpose of this study was to develop and evaluate a new imaging modality (echoscintigraphy) to reduce color blooming and acoustic shadowing in contrast sonography. After injection of various amounts (700 to 40,000 bubbles/mL) of the echo contrast agent SH-U 563A into a flow phantom, artificial vessels were insonated in the intermittent harmonic-power Doppler imaging (H-PDI) mode. The receive gain was varied from 50% to 75%. The cross-sectional area (CSA) of the tube was assessed using a new summation algorithm (echoscintigraphy) and a conventional single-frame analysis (S-FA) of the H-PDI-signals. Echoscintigraphy is based on the recording and summation of low-intensity signals that are emitted during the ultrasound (US)-induced destruction of microbubbles. Application of the summation algorithm at low-contrast concentration allowed a gain-independent automatic calculation of the CSA at medium and high gain settings. Using the S-FA method, the assessment of the vessel diameter and the CSA was gain-dependent and allowed correct measurements only from 60% to 65% gain. At a high receive-gain and high contrast concentration, S-FA resulted in an overestimation of the CSA up to 35.5%. Echoscintigraphy allows correct display of contrast-filled vessels over a wide range of gain settings at low contrast concentrations, where S-FA does not adequately display echo contrast. Thus, echoscintigraphy minimizes artefacts resulting from color blooming and acoustic shadowing.

Algorithms↗

On the design of a capillary flow phantom for the evaluation of ultrasound contrast agents at very low flow velocities.

Recently, a new imaging technology has become available that allows the evaluation of tissue perfusion using echo-contrast agents in real-time imaging: power pulse inversion imaging (PPI). Although numerous in vitro phantoms have been designed for different imaging modalities in ultrasound (US), there is a need for a phantom that mimics microcirculation and allows, in particular, the assessment of contrast replenishment kinetics following US-induced destruction of microbubbles using the new method. We, therefore, designed a new capillary flow phantom that takes the requirements of the new US imaging techniques and the physical properties of microbubbles into account and serves flow velocities in the range of microcirculation (1 to 10 mm/s). PPI studies were performed in the newly designed phantom. The contrast agent used was AF0150. We studied homogeneity of contrast distribution within the capillary phantom, constancy of contrast infusion, the dose-effect relationship and, finally, the feasibility of flow assessment using the method of contrast replenishment following US-induced microbubble destruction in a flow velocity range of 2.1 to 9.45 mm/s. Analysis of the replenishment kinetics was performed using the mathematical model f(t) = A(1 - e(-beta t)), with A representing the blood volume and beta the microbubble velocity. The new capillary phantom allowed homogeneous contrast opacification within the perfused capillaries independently of the flow. Constancy of signal intensity was achieved over a time period of almost 2 h, indicating constant contrast delivery. A strong linear correlation between the PPI signal and the contrast dose was found (r = 0.998). Analysis of the replenishment parameters revealed a strong linear relationship between parameter beta and flow (r = 0.994) as well as A * beta and flow (r = 0.984) in the observed flow range. The newly designed perfusion phantom for the evaluation of echo-contrast replenishment kinetics fulfills, at very low flow velocities, important prerequisites such as constancy of contrast delivery, homogeneity of contrast signals, linear dose-effect relation and minimal attenuation. Thus, the new phantom allows standardized analysis of contrast replenishment kinetics using real-time perfusion imaging techniques at flow velocities comparable to those of the microcirculation.

Blood Flow Velocity↗

Improvement in Endocardial Border Delineation Using Tissue Harmonic Imaging.

BACKGROUND AND METHODS: For years, tissue has been assumed to be a linear medium in diagnostic ultrasound applications; thus, no backscattered signals in the second harmonic band are expected in harmonic imaging without the injection of a contrast agent. However, it has been shown that a useful tissue image is formed even without a contrast agent. The aim of this study was to evaluate whether this tissue harmonic image provided improved visualization of endocardial borders. Fifty-six adult patients with various heart diseases were investigated using conventional two-dimensional echocardiography and tissue harmonic imaging. In 30 of these patients, the left ventricular endocardial borders were well defined in the standard parasternal and apical views using conventional two-dimensional echocardiography. In the remaining 26 patients, delineation of endocardial borders was not possible in at least two segments. The equipment used was an ATL HDI-3000 diagnostic system equipped with harmonic imaging. RESULTS: In all 56 patients, the myocardium and valves could be imaged with tissue harmonic imaging. Harmonic recordings were sharper and contained fewer clutter artifacts than conventional recordings. Most striking was the enhancement of left ventricular endocardial borders. In the 26 patients with incomplete delineation of left ventricular endocardial borders, wall motion could be evaluated in 290 of 312 (93%) segments with tissue harmonic imaging compared with only 168 of 312 (54%) segments with conventional echocardiography (P < 0.001). CONCLUSIONS: Tissue harmonic imaging improves image quality and can be used to enhance the definition of left ventricular endocardial borders. These findings can be explained by the nonlinear propagation of ultrasound within the tissue, which results in distortion of the transmitted signal and, thus, harmonic generation.

Journal Article↗