Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation.

On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. Here we evaluate the achievable accuracy in using a kV CBCT for dose calculation. Relative electron density as a function of HU was obtained for both planning CT (pCT) and CBCT using a Catphan-600 calibration phantom. The CBCT calibration stability was monitored weekly for 8 consecutive weeks. A clinical treatment planning system was employed for pCT- and CBCT-based dose calculations and subsequent comparisons. Phantom and patient studies were carried out. In the former study, both Catphan-600 and pelvic phantoms were employed to evaluate the dosimetric performance of the full-fan and half-fan scanning modes. To evaluate the dosimetric influence of motion artefacts commonly seen in CBCT images, the Catphan-600 phantom was scanned with and without cyclic motion using the pCT and CBCT scanners. The doses computed based on the four sets of CT images (pCT and CBCT with/without motion) were compared quantitatively. The patient studies included a lung case and three prostate cases. The lung case was employed to further assess the adverse effect of intra-scan organ motion. Unlike the phantom study, the pCT of a patient is generally acquired at the time of simulation and the anatomy may be different from that of CBCT acquired at the time of treatment delivery because of organ deformation. To tackle the problem, we introduced a set of modified CBCT images (mCBCT) for each patient, which possesses the geometric information of the CBCT but the electronic density distribution mapped from the pCT with the help of a BSpline deformable image registration software. In the patient study, the dose computed with the mCBCT was used as a surrogate of the 'ground truth'. We found that the CBCT electron density calibration curve differs moderately from that of pCT. No significant fluctuation was observed in the calibration over the period of 8 weeks. For the static phantom, the doses computed based on pCT and CBCT agreed to within 1%. A notable difference in CBCT- and pCT-based dose distributions was found for the motion phantom due to the motion artefacts which appeared in the CBCT images (the maximum discrepancy was found to be approximately 3.0% in the high dose region). The motion artefacts-induced dosimetric inaccuracy was also observed in the lung patient study. For the prostate cases, the mCBCT- and CBCT-based dose calculations yielded very close results (<2%). Coupled with the phantom data, it is concluded that the CBCT can be employed directly for dose calculation for a disease site such as the prostate, where there is little motion artefact. In the prostate case study, we also noted a large discrepancy between the original treatment plan and the CBCT (or mCBCT)-based calculation, suggesting the importance of inter-fractional organ movement and the need for adaptive therapy to compensate for the anatomical changes in the future.

Biophysical Phenomena↗

Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy.

PURPOSE: Four-dimensional cone-beam computed tomography (4D-CBCT) imaging is sensitive to parameters such as gantry rotation speed, number of gantry rotations, X-ray pulse rate, and tube current, as well as a patient's breathing pattern. The aim of this study is to optimize the image acquisition on a patient-specific basis while minimizing the scan time and the radiation dose. METHODS AND MATERIALS: More than 60 sets of 4D-CBCT images, each with a temporal resolution of 10 phases, were acquired using multiple-gantry rotation and slow-gantry rotation techniques. The image quality was quantified with a relative root mean-square error (RE) and correlated with various acquisition settings; specifically, varying gantry rotation speed, varying both the rotation speed and the number of rotations, and varying both the rotation speed and tube current to keep the radiation exposure constant. These experiments were repeated for three different respiratory periods. RESULTS: With similar radiation dose, 4D-CBCT images acquired with low current and low rotation speed have better quality over images obtained with high current and high rotation speed. In general, a one-rotation low-speed scan is superior to a two-rotation double-speed scan, even though they provide the same number of projections. Furthermore, it is found that the image quality behaves monotonically with the relative speed as defined by the gantry rotation speed and the patient respiratory period. CONCLUSIONS: The RE curves established in this work can be used to predict the 4D-CBCT image quality before a scan. This allows the acquisition protocol to be optimized individually to balance the desired quality with the associated scanning time and patient radiation dose.

Humans↗

Combination of integrin siRNA and irradiation for breast cancer therapy.

Up-regulation of integrin alpha(v)beta(3) has been shown to play a key role in tumor angiogenesis and metastasis. In this study, we evaluated the role of integrin alpha(v)beta(3) in breast cancer cell resistance to ionizing irradiation (IR) and tested the anti-tumor efficacy of combining integrin alpha(v) siRNA and IR. Colonogenic survival assay, cell proliferation, apoptosis, and cell cycle analysis were carried out to determine the treatment effect of siRNA, IR, or combination of both on MDA-MB-435 cells (integrin alpha(v)beta(3)-positive). Integrin alpha(v)beta(3)-negative MCF-7 cells exert more radiosensitivity than MDA-MB-435 cells. IR up-regulates integrin alpha(v)beta(3) expression in MDA-MB-435 cells and integrin alpha(v) siRNA can effectively reduce both alpha(v) and alpha(v)beta(3) integrin expression, leading to increased radiosensitivity. Integrin alpha(v) siRNA also promotes IR-induced apoptosis and enhances IR-induced G2/M arrest in cell cycle progression. This study, with further optimization, may provide a simple and highly efficient treatment strategy for breast cancer as well as other integrin alpha(v)beta(3)-positive cancer types.

Breast Neoplasms↗

Noise Reduction for Low-Dose Single-Slice Helical CT Sinograms.

Helical computed tomography (HCT) has several advantages over conventional step-and-shoot CT for imaging a relatively large object, especially for dynamic studies. However, HCT may increase X-ray exposure significantly. This work aims to reduce the radiation by lowering X-ray tube current (mA) and filtering low-mA (or dose) sinogram noise of HCT. The noise reduction method is based on three observations on HCT: (1) the axial sampling of HCT projections is nearly continuous as detection system rotates; (2) the noise distribution in sinogram space is nearly a Gaussian after system calibration (including logarithmic transform); and (3) the relationship between the calibrated data mean and variance can be expressed as an exponential functional across the field-of-view. Based on the second and third observations, a penalized weighted least-squares (PWLS) solution is an optimal choice, where the weight is given by the mean-variance relationship. The first observation encourages the use of Karhunen-Loève (KL) transform along the axial direction because of the associated correlation. In the KL domain, the eigenvalue of each principal component and the derived data variance provide the signal-to-noise ratio (SNR) information, resulting in a SNR-adaptive noise reduction. The KL-PWLS noise-reduction method was implemented analytically for efficient restoration of large volume HCT sinograms. Simulation studies showed a noticeable improvement, in terms of image quality and defect detectability, of the proposed noise-reduction method over the Ordered-Subsets Expectation-Maximization reconstruction and the conventional low-pass noise filtering with optimal cutoff frequency and/or other filter parameters.

Journal Article↗

Reconstruction for proton computed tomography by tracing proton trajectories: a Monte Carlo study.

Proton computed tomography (pCT) has been explored in the past decades because of its unique imaging characteristics, low radiation dose, and its possible use for treatment planning and on-line target localization in proton therapy. However, reconstruction of pCT images is challenging because the proton path within the object to be imaged is statistically affected by multiple Coulomb scattering. In this paper, we employ GEANT4-based Monte Carlo simulations of the two-dimensional pCT reconstruction of an elliptical phantom to investigate the possible use of the algebraic reconstruction technique (ART) with three different path-estimation methods for pCT reconstruction. The first method assumes a straight-line path (SLP) connecting the proton entry and exit positions, the second method adapts the most-likely path (MLP) theoretically determined for a uniform medium, and the third method employs a cubic spline path (CSP). The ART reconstructions showed progressive improvement of spatial resolution when going from the SLP [2 line pairs (lp) cm(-1)] to the curved CSP and MLP path estimates (5 lp cm(-1)). The MLP-based ART algorithm had the fastest convergence and smallest residual error of all three estimates. This work demonstrates the advantage of tracking curved proton paths in conjunction with the ART algorithm and curved path estimates.

Algorithms↗

Model-based image reconstruction for four-dimensional PET.

Positron emission tonography (PET) is useful in diagnosis and radiation treatment planning for a variety of cancers. For patients with cancers in thoracic or upper abdominal region, the respiratory motion produces large distortions in the tumor shape and size, affecting the accuracy in both diagnosis and treatment. Four-dimensional (4D) (gated) PET aims to reduce the motion artifacts and to provide accurate measurement of the tumor volume and the tracer concentration. A major issue in 4D PET is the lack of statistics. Since the collected photons are divided into several frames in the 4D PET scan, the quality of each reconstructed frame degrades as the number of frames increases. The increased noise in each frame heavily degrades the quantitative accuracy of the PET imaging. In this work, we propose a method to enhance the performance of 4D PET by developing a new technique of 4D PET reconstruction with incorporation of an organ motion model derived from 4D-CT images. The method is based on the well-known maximum-likelihood expectation-maximization (ML-EM) algorithm. During the processes of forward- and backward-projection in the ML-EM iterations, all projection data acquired at different phases are combined together to update the emission map with the aid of deformable model, the statistics is therefore greatly improved. The proposed algorithm was first evaluated with computer simulations using a mathematical dynamic phantom. Experiment with a moving physical phantom was then carried out to demonstrate the accuracy of the proposed method and the increase of signal-to-noise ratio over three-dimensional PET. Finally, the 4D PET reconstruction was applied to a patient case.

Algorithms↗

Four-dimensional cone-beam computed tomography using an on-board imager.

On-board cone-beam computed tomography (CBCT) has recently become available to provide volumetric information of a patient in the treatment position, and holds promises for improved target localization and irradiation dose verification. The design of currently available on-board CBCT, however, is far from optimal. Its quality is adversely influenced by many factors, such as scatter, beam hardening, and intra-scanning organ motion. In this work we quantitatively study the influence of organ motion on CBCT imaging and investigate a strategy to acquire high quality phase-resolved [four-dimensional (4D)] CBCT images based on phase binning of the CBCT projection data. An efficient and robust method for binning CBCT data according to the patient's respiratory phase derived in the projection space was developed. The phase-binned projections were reconstructed using the conventional Feldkamp algorithm to yield 4D CBCT images. Both phantom and patient studies were carried out to validate the technique and to optimize the 4D CBCT data acquisition protocol. Several factors that are important to the clinical implementation of the technique, such as the image quality, scanning time, number of projections, and radiation dose, were analyzed for various scanning schemes. The general references drawn from this study are: (i) reliable phase binning of CBCT projections is accomplishable with the aid of external or internal marker and simple analysis of its trace in the projection space, and (ii) artifact-free 4D CBCT images can be obtained without increasing the patient radiation dose as compared to the current 3D CBCT scan.

Algorithms↗

Innovative strategies for image-guided proton treatment of prostate cancer.

Proton beam therapy has a proven track record of treating non-metastatic prostate cancer with excellent disease-free survival results when using homogeneous doses between 75 and 82 CGE (Cobalt Gray Equivalent) to the prostate target volume. In clinically organ-confined prostate cancer, it may be possible, in principle, to further improve outcomes by reducing the margins of the high-dose planning target volume to the gross tumor volume and by covering the clinical target volume with a dose sufficient to control microscopic extensions of the tumor. This would allow further dose escalation without increasing the risk of acute and late effects. In this paper, we undertake a careful review of existing histopathological data that support this view and discuss technical possibilities to this approach utilizing the highly conformal characteristics of proton beams and combining them with modern 4D imaging and treatment techniques.

Humans↗

Evaluation of an efficient compensation method for quantitative fan-beam brain SPECT reconstruction.

Fan-beam collimators are designed to improve the system sensitivity and resolution for imaging small objects such as the human brain and breasts in single photon emission computed tomography (SPECT). Many reconstruction algorithms have been studied and applied to this geometry to deal with every kind of degradation factor. This paper presents a new reconstruction approach for SPECT with circular orbit, which demonstrated good performance in terms of both accuracy and efficiency. The new approach compensates for degradation factors including noise, scatter, attenuation, and spatially variant detector response. Its uniform attenuation approximation strategy avoids the additional transmission scan for the brain attenuation map, hence reducing the patient radiation dose and furthermore simplifying the imaging procedure. We evaluate and compare this new approach with the well-established ordered-subset expectation-maximization iterative method, using Monte Carlo simulations. We perform quantitative analysis with regional bias-variance, receiver operating characteristics, and Hotelling trace studies for both methods. The results demonstrate that our reconstruction strategy has comparable performance with a significant reduction of computing time.

Algorithms↗

An efficient reconstruction method for nonuniform attenuation compensation in nonparallel beam geometries based on Novikov's explicit inversion formula.

This paper investigates an accurate reconstruction method to invert the attenuated Radon transform in nonparallel beam (NPB) geometries. The reconstruction method contains three major steps: 1) performing one-dimensional phase-shift rebinning; 2) implementing nonuniform Hilbert transform; and 3) applying Novikov's explicit inversion formula. The method seems to be adaptive to different settings of fan-beam geometry from very long to very short focal lengths without sacrificing reconstruction accuracy. Compared to the conventional bilinear rebinning technique, the presented method showed a better spatial resolution, as measured by modulation transfer function. Numerical experiments demonstrated its computational efficiency and stability to different levels of Poisson noise. Even with complicated geometries such as varying focal-length and asymmetrical fan-beam collimation, the presented method achieved nearly the same reconstruction quality of parallel-beam geometry. This effort can facilitate quantitative reconstruction of single photon emission computed tomography for cardiac imaging, which may need NPB collimation geometries and require high computational efficiency.

Algorithms↗

Speedup OS-EM Image Reconstruction by PC Graphics Card Technologies for Quantitative SPECT with Varying Focal-Length Fan-Beam Collimation.

In the paper, we present a new hardware acceleration method to speedup the ordered-subsets expectation-maximization (OS-EM) algorithm for quantitative SPECT (single photon emission computed tomography) image reconstruction with varying focal-length fan-beam (VFF) collimation. By utilizing the geometrical symmetry of VFF point-spread function (PSF), compensation for object-specific attenuation and system-specific PSF are accelerated using currently available PC video/graphics card technologies. A ten-fold acceleration of quantitative SPECT reconstruction is achieved.

Journal Article↗

Density resolution of proton computed tomography.

Conformal proton radiation therapy requires accurate prediction of the Bragg peak position. Protons may be more suitable than conventional x-rays for this task since the relative electron density distribution can be measured directly with proton computed tomography (CT). However, proton CT has its own limitations, which need to be carefully studied before this technique can be introduced into routine clinical practice. In this work, we have used analytical relationships as well as the Monte Carlo simulation tool GEANT4 to study the principal resolution limits of proton CT. The noise level observed in proton CT images of a cylindrical water phantom with embedded tissue-equivalent density inhomogeneities, which were generated based on GEANT4 simulations, compared well with predictions based on Tschalar's theory of energy loss straggling. The relationship between phantom thickness, initial energy, and the relative electron density resolution was systematically investigated to estimate the proton dose needed to obtain a given density resolution. We show that a reasonable density resolution can be achieved with a relatively small dose, which is comparable to or even lower than that of x-ray CT.

Algorithms↗

An alternative solution to the nonuniform noise propagation problem in fan-beam FBP image reconstruction.

It has been observed that the variances in reconstructed images from stationary noisy projection data by fan-beam filtered backprojection (fFBP) algorithm with ramp in the filtering step and linear interpolation in the backprojection step are nonuniform across the field-of-view. This is believed to be caused by the distance-dependent 1/L2 factor in the fFBP reconstruction formula. Shift-variant filtration approach in the filtering step has been investigated to address the nonuniform noise propagation problem in fFBP. In this work, we present an alternative solution by the use of spatially variant weighting, instead of spatially invariant interpolation, in the backprojection step, while maintaining the homogeneous ramp filtering. Both theoretically predicted and empirically determined results concur and demonstrate the effectiveness of the presented alternative solution.

Algorithms↗

Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography.

We present a dual-energy (DE) transmission computed tomography (CT) reconstruction method. It is statistically motivated and features nonnegativity constraints in the density domain. A penalized weighted least squares (PWLS) objective function has been chosen to handle the non-Poisson noise added by amorphous silicon (aSi:H) detectors. A Gauss-Seidel algorithm has been used to minimize the objective function. The behavior of the method in terms of bias/standard deviation tradeoff has been compared to that of a DE method that is based on filtered back projection (FBP). The advantages of the DE PWLS method are largest for high noise and/or low flux cases. Qualitative results suggest this as well. Also, the reconstructed images of an object with opaque regions are presented. Possible applications of the method are: attenuation correction for positron emission tomography (PET) images, various quantitative computed tomography (QCT) methods such as bone mineral densitometry (BMD), and the removal of metal streak artifacts.

Algorithms↗