PubMed Health⌕ Search

PubMed · 17197125

Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy.

Abstract

PURPOSE: Four-dimensional cone-beam computed tomography (4D-CBCT) imaging is sensitive to parameters such as gantry rotation speed, number of gantry rotations, X-ray pulse rate, and tube current, as well as a patient's breathing pattern. The aim of this study is to optimize the image acquisition on a patient-specific basis while minimizing the scan time and the radiation dose. METHODS AND MATERIALS: More than 60 sets of 4D-CBCT images, each with a temporal resolution of 10 phases, were acquired using multiple-gantry rotation and slow-gantry rotation techniques. The image quality was quantified with a relative root mean-square error (RE) and correlated with various acquisition settings; specifically, varying gantry rotation speed, varying both the rotation speed and the number of rotations, and varying both the rotation speed and tube current to keep the radiation exposure constant. These experiments were repeated for three different respiratory periods. RESULTS: With similar radiation dose, 4D-CBCT images acquired with low current and low rotation speed have better quality over images obtained with high current and high rotation speed. In general, a one-rotation low-speed scan is superior to a two-rotation double-speed scan, even though they provide the same number of projections. Furthermore, it is found that the image quality behaves monotonically with the relative speed as defined by the gantry rotation speed and the patient respiratory period. CONCLUSIONS: The RE curves established in this work can be used to predict the 4D-CBCT image quality before a scan. This allows the acquisition protocol to be optimized individually to balance the desired quality with the associated scanning time and patient radiation dose.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tianfang Li, Lei Xing. 2006-12-29. Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy.. https://doi.org/10.1016/j.ijrobp.2006.10.024

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Global Genomic Surveillance.

Global genomic surveillance has emerged as a foundational pillar of public health in the twenty-first century, enabling real-time tracking of pathogen evolution and informing outbreak response. This chapter examines the strategic architecture of global genomic surveillance, focusing on its application to arboviruses such as chikungunya virus (CHIKV). It explores the integration of genomic data with epidemiological, clinical, and environmental information within a One Health framework, while addressing critical challenges in governance, equity, and interoperability. The discussion covers the entire genomic surveillance workflow, from sample collection and sequencing to bioinformatic analysis and phylogenetic inference, and highlights the transformative role of artificial intelligence (AI) in predictive surveillance. By analyzing global initiatives, operational barriers, and emerging technologies, this chapter underscores the necessity of sustainable, equitable, and interoperable genomic systems to proactively address current and future infectious disease threats.

Humans↗

Systematic Dissection of Key Driver Perturbation Signatures in Single Cells via ECCITE-seq.

CRISPR screens, such as expanded CRISPR-compatible cellular indexing of transcriptomes and epitopes by sequencing (ECCITE-seq), enable the simultaneous measurement of transcriptomes, gRNA identity, and cell-surface protein expression at single-cell resolution to systematically interrogate gene function. This platform provides a powerful and scalable experimental approach for validating disease-associated regulators identified by large-scale association studies and other computational methods, including network-based analyses of multi-omics data. Here, as an example application, we describe an ECCITE-seq framework to characterize the transcriptomic consequences of perturbing multiple neuronal key driver genes associated with Alzheimer's disease (AD) in human-induced pluripotent stem cell (hiPSC)-derived neurons. More broadly, by integrating customized pooled gRNA libraries with different CRISPR effectors across multiple cell types, this approach allows for the assessment of the regulatory impact of candidate genes implicated in development and disease processes.

Humans↗

Identification of Genome-Wide Chromatin Structural Aberration in Cancer by Hi-C Analysis.

Aberrant three-dimensional genome organization is a hallmark of cancer, often driving oncogene activation through mechanisms such as enhancer hijacking. High-throughput chromosome conformation capture (Hi-C) maps these interactions on a genome-wide scale. Unlike earlier dilution-based methods, in situ Hi-C performs proximity ligation within intact nuclei, minimizing random ligation noise and enabling fine-scale structure detection. This chapter describes an optimized in situ Hi-C protocol tailored for cancer cell lines using MboI digestion and biotin-mediated pull-down to generate high-complexity libraries. We further outline a computational workflow that extends beyond standard topological mapping of compartments and topologically associating domains to identify cancer-specific aberrations. Specifically, we focus on detecting chromosomal rearrangements (structural variants) and characterizing the distinct circular topology of extrachromosomal DNA. This integrated experimental and analytical framework provides the necessary tools to dissect the spatial dysregulation underlying tumor evolution.

Humans↗