PubMed Health⌕ Search

Biomedical subjects

Tim Herrmann

Publications and source records attributed to Tim Herrmann.

2 recordsLinked to original sources

Short-cut method for the correction of light attenuation influences in the experimental data obtained from confocal laser scanning microscopy.

Based on Lambert-Beer law and the light attenuation model, a new method will be introduced in this work in order to eliminate the disturbances caused by signal attenuation in the experimental data measured by confocal laser scanning microscopy (CLSM). This new method considers the attenuation effects which depend on concentration of fluorophore-labelled protein as well as attenuation effects which are independent from protein concentration. Furthermore, no solvent additive is required in order to match the refraction index of solvent to bead material. The determination of correction factors is, thus, easily done using the currently investigated chromatographic phase system, so that the validity of the correction factors in the current system can be guaranteed. The introduced correction method has been applied for the investigation of intraparticle protein distribution inside an HIC (hydrophobic interaction chromatography) particle.

Light↗

Generation of equally sized particle plaques using solid-liquid suspensions.

A device is presented for the generation of equally sized plaques of sensitive particles in a 96-well format. The resulting particle plaques can be used for the measurement of adsorption isotherms and uptake kinetics in protein chromatography or for immobilization reactions. The particle plaques are formed from suspensions with a vacuum device that is designed as a reusable sandwich module. The particles are retained by a mesh while the solvent is removed by the vacuum. As most particles used for protein chromatography are sensitive to mechanical stress and dehydration, the vacuum device is gentle enough to allow the use of these particles, thus eliminating the uncertainty of slurry preparation and pipetting. Apparatus characteristics and preparation procedures are described precisely. The physical intactness of the particles after the preparation procedure is proved by microscopic analysis. Data on the uniformity of the obtained resin plaques with respect to the reproducibility of their adsorption performance is given. Finally, adsorption isothermal and kinetic data of BSA on an ordinary HIC system obtained by high-throughput measurements are shown as an application example.

Adsorption↗