PubMed Health⌕ Search

Biomedical subjects

Timo Sänger

Publications and source records attributed to Timo Sänger.

4 recordsLinked to original sources

Low volume amplification and sequencing of mitochondrial DNA on a chemically structured chip.

Low volume (LV) amplification (1 microL) of nuclear DNA (nucDNA) on a chemically structured chip is an appropriate and highly sensitive method to simultaneously amplify amelogenin and 15 forensically relevant short tandem repeats (STR). In this study, a combined method using on-chip LV amplification of mitochondrial DNA (mtDNA) and subsequent on-chip LV cycle sequencing was established to obtain a method, which is sensitive and robust enough to allow reliable analysis of DNA amounts representing the single cell level. All the necessary steps of the procedure--except for the purification of the sequencing products--were accomplished within the same final 2-microL reaction volume.

DNA Fingerprinting↗

Low-volume amplification on chemically structured chips using the PowerPlex16 DNA amplification kit.

In forensic DNA analysis, improvement of DNA typing technologies has always been an issue. It has been shown that DNA amplification in low volumes is a suitable way to enhance the sensitivity and efficiency of amplification. In this study, DNA amplification was performed on a flat, chemically structured glass slide in 1-microl reaction volumes from cell line DNA contents between 1,000 and 4 pg. On-chip DNA amplification reproducibly yielded full allelic profiles from as little as 32 pg of template DNA. Applicability on the simultaneous amplification of 15 short tandem repeats and of a segment of the Amelogenin gene, which are routinely used in forensic DNA analysis, is shown. The results are compared to conventional in-tube amplification carried out in 25-microl reaction volumes.

Case-Control Studies↗

Phantom mutation hotspots in human mitochondrial DNA.

Phantom mutations are systematic artifacts generated in the course of the sequencing process. Contra common belief these artificial mutations are nearly ubiquitous in sequencing results, albeit at frequencies that may vary dramatically. The amount of artifacts depends not only on the sort of automated sequencer and sequencing chemistry employed, but also on other lab-specific factors. An experimental study executed on four samples under various combinations of sequencing conditions revealed a number of phantom mutations occurring at the same sites of mitochondrial DNA (mtDNA) repeatedly. To confirm these and identify further hotspots for artifacts, > 5000 mtDNA electropherograms were screened for artificial patterns. Further, > 30 000 published hypervariable segment I sequences were compared at potential hotspots for phantom mutations, especially for variation at positions 16085 and 16197. Resequencing of several samples confirmed the artificial nature of these and other polymorphisms in the original publications. Single-strand sequencing, as typically executed in medical and anthropological studies, is thus highly vulnerable to this kind of artifacts. In particular, phantom mutation hotspots could easily lead to misidentification of somatic mutations and to misinterpretations in all kinds of clinical mtDNA studies.

Artifacts↗

Different methods to determine length heteroplasmy within the mitochondrial control region.

The first and second hypervariable regions of the human mitochondrial DNA control region contain two homopolymeric stretches of cytosine (nt 16184-16193 and nt303-315, respectively). According to the Cambridge reference sequence these homopolymeric stretches are interrupted by thymine (T), at positions 16189 and 310, respectively. Monotonous runs of the same base have been suggested to be hot spots for mutations, probably caused by replication slippage, resulting in length heteroplasmy. This paper describes a rapid method based on restriction cleavage of labelled PCR products encompassing the homopolymeric tract in HVII to quantify the relative proportions of different length variants present in an individual. To compare the accuracy of this method, cloned PCR products from several heteroplasmic individuals have been additionally sequenced.

Artifacts↗