PubMed Health⌕ Search

PubMed · 16167362

Phantom mutation hotspots in human mitochondrial DNA.

Abstract

Phantom mutations are systematic artifacts generated in the course of the sequencing process. Contra common belief these artificial mutations are nearly ubiquitous in sequencing results, albeit at frequencies that may vary dramatically. The amount of artifacts depends not only on the sort of automated sequencer and sequencing chemistry employed, but also on other lab-specific factors. An experimental study executed on four samples under various combinations of sequencing conditions revealed a number of phantom mutations occurring at the same sites of mitochondrial DNA (mtDNA) repeatedly. To confirm these and identify further hotspots for artifacts, > 5000 mtDNA electropherograms were screened for artificial patterns. Further, > 30 000 published hypervariable segment I sequences were compared at potential hotspots for phantom mutations, especially for variation at positions 16085 and 16197. Resequencing of several samples confirmed the artificial nature of these and other polymorphisms in the original publications. Single-strand sequencing, as typically executed in medical and anthropological studies, is thus highly vulnerable to this kind of artifacts. In particular, phantom mutation hotspots could easily lead to misidentification of somatic mutations and to misinterpretations in all kinds of clinical mtDNA studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anita Brandstätter, Timo Sänger, Sabine Lutz-Bonengel, Walther Parson, Eliane Béraud-Colomb, Bo Wen, Qing-Peng Kong, Claudio M Bravi, Hans-Jürgen Bandelt. 2005. Phantom mutation hotspots in human mitochondrial DNA.. https://doi.org/10.1002/elps.200500307

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗