Segmentation of elastographic images using a coarse-to-fine active contour model.

Delineation of radiofrequency-ablation-induced coagulation (thermal lesion) boundaries is an important clinical problem that is not well addressed by conventional imaging modalities. Elastography, which produces images of the local strain after small, externally applied compressions, can be used for visualization of thermal coagulations. This paper presents an automated segmentation approach for thermal coagulations on 3-D elastographic data to obtain both area and volume information rapidly. The approach consists of a coarse-to-fine method for active contour initialization and a gradient vector flow, active contour model for deformable contour optimization with the help of prior knowledge of the geometry of general thermal coagulations. The performance of the algorithm has been shown to be comparable to manual delineation of coagulations on elastograms by medical physicists (r = 0.99 for volumes of 36 radiofrequency-induced coagulations). Furthermore, the automatic algorithm applied to elastograms yielded results that agreed with manual delineation of coagulations on pathology images (r = 0.96 for the same 36 lesions). This algorithm has also been successfully applied on in vivo elastograms.

Algorithms↗

Anthropomorphic breast phantoms for testing elastography systems.

Two equivalent anthropomorphic breast phantoms were constructed, one for use in ultrasound elastography and the other in magnetic resonance (MR) elastography. A complete description of the manufacturing methods is provided. The materials used were oil-in-gelatin dispersions, where the volume percent oil differentiates the materials, primarily according to Young's moduli. Values of Young's moduli are in agreement with in vitro ranges for the corresponding normal and abnormal breast tissues. Ultrasound and nuclear magnetic resonance (NMR) properties are reasonably well represented. Phantoms of the type described promise to aid researchers who are developing hardware and software for elastography. Examples of ultrasound and MR elastograms of the phantoms are included to demonstrate the utility of the phantoms. Also, the level of stability of elastic properties of the component materials is quantified over a 15-month period. Such phantoms can serve as performance-assessing intermediaries between simple phantoms (consisting, for example, of homogeneous cylindrical inclusions in a homogeneous background) and a full-scale clinical trial. Thus, premature clinical trials may be avoided.

Anthropometry↗

A novel performance descriptor for ultrasonic strain imaging: a preliminary study.

Ultrasonic strain imaging that uses signals from conventional diagnostic ultrasound systems is capable of showing the contrast of tissue elasticity, which provides new diagnostically valuable information. To assess and improve the diagnostic performance of ultrasonic strain imaging, it is essential to have a quantitative measure of image quality. Moreover, it is useful if the image quality measure is simple to interpret and can be used for visual feedback while scanning and as a training tool for operator performance evaluation. This report describes the development of a novel quantitative method for systematic performance assessment that is based on the combination of measures of the accuracy of motion tracking and consistency among consecutive strain fields. The accuracy of motion tracking assesses the reliability of strain images. The consistency among consecutive strain images assesses the signal quality in strain images. The clinical implications of the proposed method to differentiate good or poor strain images are discussed. Results of experiments with tissue-mimicking phantoms and in vivo breast-tissue data demonstrate that the performance measure is a useful method for automatically rating elasticity image quality.

Algorithms↗

Breast lesions: evaluation with US strain imaging--clinical experience of multiple observers.

PURPOSE: To prospectively determine the accuracy of using an ultrasonographic (US) strain imaging technique known as lesion size comparison to differentiate benign from malignant breast lesions. MATERIALS AND METHODS: Institutional Review Board approval and patient informed consent were obtained for this HIPPA-compliant study. US strain imaging was performed prospectively for 89 breast lesions in 88 patients. Lesions were imaged by using freehand compression and a real-time strain imaging algorithm. Five observers obtained manual measurements of lesion height, width, and area from B-mode and strain images. By using these size measurements, individual observer and group performances were assessed by using the area under the receiver operating characteristic curve (A(z)). The performance of a single size parameter versus that of a combination of size parameters was evaluated by using univariate and multivariate logistic regression. RESULTS: Group A(z) values showed that width ratio and area ratio yielded the best results for differentiating benign and malignant breast lesions, and they were not statistically different from one another (P = .499). For the group, the performance of area and width, which was superior to that of height and aspect ratio, was statistically significant for all cases (P < .011) except for those that compared area with aspect ratio (P = .118). By using a group threshold of 1.04 for width ratio and 1.13 for area ratio, the sensitivity and specificity of the technique were 96% and 21%, respectively, for width and 96% and 24%, respectively, for area. The best observer achieved a sensitivity of 96% and a specificity of 61% by using the area ratio. For all but one observer, combined size parameters did not improve observer performance (P > .258). Significant interobserver performance variability was observed (P < .001). CONCLUSION: Results suggest that US strain imaging has the potential to aid diagnosis of breast lesions. However, manually tracing lesion boundaries for size ratio differentiation in a busy clinical setting did not match the diagnostic performance levels previously reported. Focusing on measurements of lesion width, along with additional observer training or automated processes, may yield a suitable method for routine clinical application.

Adult↗

Spherical lesion phantoms for testing the performance of elastography systems.

A set of three cubic one-litre phantoms containing spherical simulated lesions was produced for use in comparing lesion detection performance of different elastography systems. The materials employed are known to be stable in heterogeneous configurations regarding geometry and elastic contrast identical with (storage modulus of lesion material) / (storage modulus of background material), and regarding ultrasound and NMR properties. The materials mimic soft tissues in terms of elastic, ultrasound and NMR properties. Each phantom has only one value of elastic contrast (3.3, 4.6 or 5.5) and contains arrays of 1.6 mm, 2 mm, 3 mm and 4 mm diameter spherical simulated lesions. All the spheres of a given diameter are arranged in a regular array with coplanar centres. Elastograms of an array made with ultrasound allow determination of the depth range over which lesions of that diameter and elastic contrast can be detected. Two phantoms are made from agar-plus-gelatin-based materials, and one is made from oil-in-gelatin dispersions. The methods for producing the phantoms are described in detail. Lesion detection performances for two ultrasound systems, both operating at about 7.5 MHz and focused at about 5 cm, were quantified with distinctions between the two systems demonstrated. Neither system was capable of detecting any of the 1.6 mm lesions. Phantoms such as these should be useful in research labs that are refining hardware and/or software for elastography.

Agar↗

Optimization of angular and frequency compounding in ultrasonic attenuation estimations.

Previous reports have shown that the variance in ultrasound attenuation measurements is reduced when spatial and frequency compounding were applied in data acquisition and analysis. This paper investigates factors affecting the efficiency of compound attenuation imaging methods. A theoretical expression is derived that predicts the correlation between attenuation versus frequency slope (beta) estimates as a function of the increment between measurement frequencies (deltaf ) and the angular separation between beam lines (Delta (theta)). Theoretical results are compared with those from attenuation measurements on tissue-mimicking phantoms and from simulation data. Both predictions and measurement results show that the correlation between beta estimates as a function of (Delta f ) is independent of the length of the radio frequency (rf) data segment over which beta is derived. However, it decreases with an increase in the length of the data segment used in power spectra estimates. In contrast, the correlation between beta estimates as a function of delta(theta) decreases when the rf data segment length is longer or the frequency of the signal is higher. O 2005 Acoustical Society of America.

Acoustics↗

Viscoelastic characterization of in vitro canine tissue.

Mechanical properties of biological tissues are of interest for assessing the performance of elastographic methods that evaluate the stiffness characteristics of tissue. The mechanical properties of interest include the frequency-dependent complex moduli, storage and loss moduli of tissues. Determination of the mechanical properties of biological tissues is often limited by proper geometry of the sample, as well as homogeneity of the stress-strain relationship. Measurements were performed on in vitro canine liver tissue specimens, over a frequency range from 0.1 to 400 Hz. Tests were conducted using an EnduraTEC ELF 3200, a dynamic testing system for determining the mechanical properties of materials. Both normal tissues and thermal lesions prepared by radio frequency ablation were tested. Experiments were conducted by uniaxially compressing tissue samples using Plexiglas platens larger than the specimens and measuring the load response. The resulting moduli spectra were then fit to a modified Kelvin-Voigt model, called the Kelvin-Voigt fractional derivative model. The data agree well with the model and in comparing the results from the normal tissue with that of the thermal lesions, the concept of a complex modulus contrast is introduced and its applications to elastography are discussed.

Animals↗

In vivo real-time freehand palpation imaging.

Previous experience with laboratory fixtures and off-line processing of elasticity data showed that problems occurring in data acquisition often resulted in poor elasticity image quality. A system for real-time estimation and display of tissue elastic properties using a clinical ultrasonic imaging system has been developed. A brief description of that system and the initial clinical tests of that system are reported. Experience with real-time freehand elasticity imaging shows that images with high contrast-to-noise ratios are consistently obtained. Images of breast lesions were acquired with freehand palpation using standard linear-array ultrasound (US) transducers. Results in volunteer patients show that high-quality elasticity images are easily obtained from in vivo breast studies. The key element to successful scanning is real-time visual feedback of B-mode and strain images that guide the patient positioning and compression direction. Results show that individual images of axial strain in tissues can be quite misleading, and that a "movie loop" of side-by-side B-mode and strain images provides significantly more information. Our preliminary data suggest that the strain image sequences for various breast pathologies are unique. For example, strain images of fibroadenomas lose contrast with increasing precompression, but those of invasive ductal carcinoma have high negative contrast (dark relative to "normal" tissue) for a wide range of precompression. In addition, a comparison of the lesion area measured in B-mode vs. strain images, for a representative image from the sequence, appears to be a sensitive criterion for separating invasive ductal carcinoma from cyst and fibroadenoma.

Algorithms↗

A finite-element approach for Young's modulus reconstruction.

Modulus imaging has great potential in soft-tissue characterization since it reveals intrinsic mechanical properties. A novel Young's modulus reconstruction algorithm that is based on finite-element analysis is reported here. This new method overcomes some limitations in other Young's modulus reconstruction methods. Specifically, it relaxes the force boundary condition requirements so that only the force distribution at the compression surface is necessary, thus making the new method more practical. The validity of the new method is demonstrated and the performance of the algorithm with noise in the input data is tested using numerical simulations. Details of how to apply this method under clinical conditions is also discussed.

Algorithms↗

A modified block matching method for real-time freehand strain imaging.

This manuscript reports a technical innovation that has been developed for real-time, freehand strain imaging. This work is based on a well-known block-matching algorithm with two significant modifications. First, since displacements are estimated row-by-row, displacement estimates from the previous row are used to predict the displacement estimates in the current row, thereby drastically reducing the search-region size and increasing computational efficiency. Second, a displacement error detection and correction method is developed to overcome the local tracking errors that may be more severe with freehand scanning and thereby improve the robustness of the algorithm. This algorithm has been implemented on a clinical ultrasound imaging system, and with real-time imaging feedback, long sequences of high quality strain images are observed using freehand compression. Displacement estimation errors with this method are experimentally measured and compared with results from simulation. We report only a specific implementation, with no comparison to other displacement estimators in the literature and no optimization of this specific technique. Images of tissue-mimicking phantoms with small spherical targets are used to test the ability to detect small lesions using the strain imaging technique. In vivo strain images of breast and thyroid are also shown.

Algorithms↗

AAPM/RSNA physics tutorial for residents: topics in US: beyond the basics: elasticity imaging with US.

A new mode of imaging with ultrasonography (US) is under development in several laboratories around the world. This technique allows estimation of some measure of the viscoelastic properties of tissue. The information displayed in the images is a surrogate for that obtained with manual palpation. Fundamental concepts in elasticity imaging include stress, strain, and the elastic modulus; strain imaging has received the most attention from researchers. A system for elasticity imaging is under development that produces images of mechanical strain in real time by means of a freehand scanning technique. This system is integrated into a clinical US system without any external equipment and involves software changes only. Data obtained with this system demonstrate that the relative stiffness of many fibroadenomas changes as they and the surrounding tissue are deformed. At elasticity imaging of in vivo breast lesions, invasive ductal carcinomas appear, on average, more than twice as large on the elasticity image than on the B-mode image, but fibroadenomas and cysts are nearly equal in size on the two image types. The usefulness of this technology and the new information it provides suggest that it might soon be available on commercial US systems.

Algorithms↗