PubMed Health⌕ Search

Biomedical subjects

Toyohide Takeuchi

Publications and source records attributed to Toyohide Takeuchi.

At least 19 recordsLinked to original sources

On-line sample extraction and enrichment of non-steroidal anti-inflammatory drugs by pre-column in capillary liquid chromatography mass spectrometry.

A rapid and sensitive analytical method has been developed for the simultaneous determination of 16 non-steroidal anti-inflammatory drugs (NSAIDs) in human plasma by capillary liquid chromatography (LC) and quadrupole mass spectrometry with electrospray ionization operated in the negative ion mode. The sample clean-up and enrichment on a pre-column were accomplished on-line to improve the sensitivity. This method greatly reduced sample preparation time and sample volume compared with off-line sample extraction methods and conventional LC methods, respectively. The recoveries of NSAIDs from human plasma were 56.7-96.9%. The total analytical time for a single analytical run was approximately 15 min. The detection limits of NSAIDs were 0.001-0.075 microg ml(-1) using a selected ion monitoring mode.

Anti-Inflammatory Agents, Non-Steroidal↗

Determination of iodide in seawater samples by ion chromatography with chemically-bonded poly(ethylene glycol) stationary phase.

An ion chromatographic method for the rapid and direct determination of iodide in seawater is reported. Poly(ethylene glycol) (PEG) groups were chemically bonded onto silica gel or C30-bonded silica gel via diol groups. PEG-bonded C30 binary phases allowed determination of iodide in seawater samples without any interference. Effects of eluent composition on retention behavior of inorganic anions have been investigated. Both cation and anion of the eluent affected the retention of analyte anions. The retention time of anions increased with increasing eluent concentration. The detection limit for iodide obtained by injecting 0.2 microl of sample was 13 microg l(-1) (S/N=3) while the limit of quantitation was 43 microg l(-1) (S/N=10). The present method was successfully applied to the rapid and direct determination of iodide in seawater with long-term durability.

Chromatography, Ion Exchange↗

Development of an on-line immobilized-enzyme reversed-phase HPLC method for protein digestion and peptide separation.

This paper describes use of a novel glass bead-based immobilized-enzyme micro column for simple and swift on-line protein digestion then peptide separation by reversed-phase HPLC. The inexpensive and easily made immobilized-enzyme micro column was prepared from aminopropyl controlled-pore glass that was reacted first with glutaraldehyde then with trypsin in the presence of phosphate buffer. Tryptic digestion of bovine serum albumin (BSA) was achieved simply by passing pretreated protein solution through the laboratory made immobilized-trypsin column; the tryptic fragments were then separated by reversed-phase HPLC. The peptide separation was found to be identical to separation of a sample which had undergone conventional enzymatic protein digestion in solution. Digestion of BSA by the immobilized-trypsin column decreased with increasing flow rate of the solution through the column, and 1.0 muL min(-1) was found to be the optimum flow rate for on-line protein digestion with our system. It was also found that the sample required pretreatment with urea before injection, because of a change in the properties of the protein in the presence of urea, and the immobilized-trypsin column lost its function in the presence of acetonitrile. This on-line proteomics system enables simple and rapid protein digestion and was successfully applied to partially micro two-dimensional (2D) chromatographic separation of proteins.

Chromatography, High Pressure Liquid↗

Rapid and simultaneous determination of nonsteroidal anti-inflammatory drugs in human plasma by LC-MS with solid-phase extraction.

A rapid, selective and sensitive analytical method for the simultaneous determination of 16 nonsteroidal anti-inflammatory drugs (NSAIDs) in human plasma was carried out using Oasis HLB solid-phase extraction (SPE), followed by reversed-phase high-performance liquid chromatography and quadrupole mass spectrometry with electrospray ionization operated in the negative ion mode. The recoveries of NSAIDs from human plasma by SPE were greater than 76.7%. The use of a short column packed with small particles enabled rapid and simultaneous determination within 7 min. The detection limits for the NSAIDs were 0.01-0.9 mug/ml using the selected ion monitoring mode.

Anti-Inflammatory Agents, Non-Steroidal↗

Serial separation of cations and anions by ion chromatography using the peak parking technique and sulfosalicylic acid as the eluent.

An improvement of the peak parking technique is described for the serial determination of cations (Na+, NH+4, K+, Mg2+, and Ca2+) and anions (Cl-, SO2-(4), and NO-3) using a single pump, a single eluent and a single detector. The present system used commercially-available unmodified cation exchange and anion exchange columns, which were attached to each switching valve. When 1.75 mM 5-sulfosalicylic acid was used as the eluent, serial separation of the above cations and anions was achieved in less than 20 min. The proposed ion chromatographic method was successfully applied to the serial determination of cations and anions in tap water and river water samples. The limits of detection at S/N=3 for an injection of 20 microl were 16-68 ppb (microg/l) for cations and 15-28 ppb for anions.

Journal Article↗

On-line precolumn enrichment of bisphenol A using boronate column in microcolumn liquid chromatography.

The application of a boronate precolumn in the trace determination of 4,4'-isopropylidenediphenol (bisphenol A or BPA) in aqueous solution was investigated by microcolumn liquid chromatography (LC). BPA was enriched by a precolumn packed with TSK(gel) boronate and it was then injected (back-flushed) into an ODS separation column. Comparing to a conventional syringe injection, a better peak shape was obtained via the boronate precolumn injection, and the calculated theoretical plate number improvement was approximately two folds. The relative standard deviations for the retention time, peak area and peak height were 0.12, 3.0 and 1.8%, respectively. The system is linear (R2>0.99) within the working sample concentration and sample-volume ranges, and it presents a detection limit of 0.09 microg L(-1)(S/N=3) when a 0.2 mL sample was enriched. Recovery values of the proposed method were between 107 and 123%, and this method was applied satisfactorily to the determination of BPA in commercially available bottled drink samples. The boronate precolumn was proven to produce better sensitivity than that of an ODS or C30 precolumn as long as the enrichment of BPA in aqueous samples is concerned.

Benzhydryl Compounds↗

Peak parking technique for the simultaneous determination of anions and cations.

An ion chromatography method is described for the simultaneous determination of anions (Cl-, NO3-, and SO4(2-)) and cations (Na+, NH4+, K+, Mg2+, and Ca2+) using a single pump, a single eluent and a single detector. An anion-exchange column modified with chondroitin sulfate C facilitated the elution of the above three anions using 5 mM tartaric acid as the eluent in isocratic mode, whereas the same eluent facilitated the separation of the above five cations on a commercially-available cation-exchange column. The separation columns were connected in series via two six-port switching valves, so the required cation-exchange or anion-exchange separation could be carried out by selecting the appropriate positions for the switching valves. The separations were completed in 30 min.

Journal Article↗

Photometric detection of cyclodextrins in liquid chromatography by using iodine generated electrochemically in-situ.

A method has been developed for photometric detection of cyclodextrins (CD) in liquid chromatography using iodine (I2) generated electrochemically in-situ. Iodide ion in the mobile phase was electrochemically oxidized to I2 which was subsequently reacted with I-, in an electrochemical flow cell, forming I3-. The absorbance of I3- was found to be greatly enhanced when CD were present in the mobile phase. The absorbance enhancement was caused by the change in the mole fraction of I3-, because of the inclusion reaction of I3- with CD. On the basis of this phenomenon, CD were detected by means of a photodiode-array UV-visible detector positioned downstream of the electrochemical flow cell. The signals were found to be linearly dependent on CD concentration. Because the formation constants of I3- with CD decrease in the order alpha-CD>beta-CD>gamma-CD, alpha-CD was most detectable by the method. Detection limits were 1.0 micromol L(-1) for alpha-CD, 65 micromol L(-1) for monoG1-beta-CD, 100 micromol L(-1) for beta-CD, and 200 micromol L(-1) for gamma-CD.

Chromatography, High Pressure Liquid↗

Determination of iodide in seawater and edible salt by microcolumn liquid chromatography with poly(ethylene glycol) stationary phase.

An ion chromatography method for rapid and direct determination of iodide in seawater and edible salt is reported. Separation was achieved using a laboratory-made C30 packed column (100 mm x 0.32 mm i.d.) modified with poly(ethylene glycol) (PEG). Effects of eluent composition on retention behavior of inorganic anions have been investigated. Both cation and anion of the eluent affected the retention of analyte anions. The retention time of anions increased with increasing eluent concentration when lithium chloride, sodium chloride, potassium chloride, sodium sulfate, magnesium sulfate were used as the eluent, while it decreased with increasing eluent concentration when ammonium sulfate was used as the eluent. The detection limit for iodide obtained by injecting 0.2 microl of sample was 9 microg/l (S/N = 3). The present method was successfully applied to the rapid and direct determination of iodide in seawater and edible salt samples. Partition may be involved in the present separation mode.

Acetonitriles↗

Application of polymethacrylate resin as stationary phase in liquid chromatography with UV detection for C1-C7 aliphatic monocarboxylic acids and C1-C7 aliphatic monoamines.

The application of unfunctionized polymethacrylate resin (TSKgel G3000PWXL) as a stationary phase in liquid chromatography with UV detection for C1-C7 aliphatic monocarboxylic acids (formic acid, acetic acid, propionic acid, butyric acid, isovaleric acid, valeric acid, 3,3-dimethylbutyric acid, 4-methylvaleric acid, hexanoic acid, 2-methylhexanoic acid, 5-methylhexanoic acid and heptanoic acid) and C1-C7 aliphatic monoamines (methylamine, ethylamine, propylamine, isobutylamine, butylamine, isoamylamine, amylamine, 1,3-dimethylbutylamine, hexylamine, 2-heptylamine and heptylamine) was carried out. Using dilute sulfuric acid as the eluent, the TSKgel G3000PWXL, resin acted as an advanced stationary phase for these C1-C7 carboxylic acids. Excellent simultaneous separation and symmetrical peaks for these C1-C7 carboxylic acids were achieved on a TSKgel G3000PWXL column (150 mm x 6 mm i.d.) in 60 min with 0.25 mM sulfuric acid containing 1 mM 2-methylheptanoic acid at pH 3.3 as the eluent. Using dilute sodium hydroxide as the eluent, the TSKgel G3000PWXL resin also behaved as an advanced stationary phase for these C1-C7 amines. Excellent simultaneous separation and good peaks for these C1-C7 amines were achieved on the TSKgel G3000PWXL column in 60 min with 10 mM sodium hydroxide containing 0.5 mM 1-methylheptylamine at pH 11.9 as the eluent.

Amines↗

Separation and conductimetric detection of C1-C7 aliphatic monocarboxylic acids and C1-C7 aliphatic monoamines on unfunctionized polymethacrylate resin columns.

The application of unfunctionized polymethacrylate resin (TSKgel G3000PWXL) as a stationary phase in liquid chromatography with conductimetric detection for C1-C7 aliphatic monocarboxylic acids (formic acid, acetic acid, propionic acid, butyric acid, isovaleric acid, valeric acid, 3,3-dimethylbutyric acid, 4-methylvaleric acid, hexanoic acid, 2-methylhexanoic acid, 5-methylhexanoic acid and heptanoic acid) and C1-C7 aliphatic monoamines (methylamine, ethylamine, propylamine, isobutylamine, butylamine, isoamylamine, amylamine, 1,3-dimethylbutylamine, hexylamine, 2-heptylamine and heptylamine) was attempted with C8 aliphatic monocarboxylic acids (2-propylvaleric acid, 2-ethylhexanoic acid, 2-methylheptanoic acid and octanoic acid) and C8 aliphatic monoamines (1,5-dimethylhexylamine, 2-ethylhexylamine, 1-methylheptylamine and octylamine) as eluents, respectively. Using 1 mM 2-methylheptanoic acid at pH 4.0 as the eluent, excellent separation and relatively high sensitive detection for these C1-C7 carboxylic acids were achieved on a TSKgel G3000PWXL column (150 mm x 6 mm i.d.) in 60 min. Using 2 mM octylamine at pH 11.0 as the eluent, excellent separation and relatively high sensitive detection for these C1-C7 amines were also achieved on the TSKgel G3000PWXL column in 60 min.

Amines↗

Retention behavior of C1-C6 aliphatic monoamines on anion-exchange and polymethacrylate resins with heptylamine as eluent.

Retention behavior of C1-C6, aliphatic monoamines (methylamine, ethylamine, propylamine, butylamine, amylamine and hexylamine) on columns (150 mm x 6 mm i.d.) packed with various anion-exchange resins (styrene-divinylbenzene (PS-DVB) copolymer-based strongly basic anion-exchange resin: TSKgel SAX, polymethacrylate-based strongly basic anion-exchange resin: TSKgel SuperQ-5PW and polymethacrylate-based weakly basic anion-exchange resin: TSKgel DEAE-5PW) and unfunctionized polymethacrylate resins (TSKgel G5000PW and TSKgel G3000PWXL) was investigated with basic solutions (sodium hydroxide and heptylamine) as the eluents. Due to strongly electrostatic repulsion (ion-exclusion effect) between these anion-exchange resins and these amines, peak resolution between these amines on these anion-exchange resin columns was unsatisfactory with both sodium hydroxide and heptylamine as the eluents. In contrast, these polymethacrylate resins were successfully applied as the stationary phases for the separation of these C1-C6 amines with heptylamine as eluent, because of both small hydrophobicity and small cation-exchange ability of these resins. Excellent simultaneous separation, highly sensitive conductimetric detection and symmetrical peaks for these C1-C6 amines were achieved on the TSKgel G3000PWXL column in 35 min with 5 mM heptylamine at pH 11.1 as the eluent.

Amines↗

Sample enrichment by using monolithic precolumns in microcolumn liquid chromatography.

An on-line sample enrichment system was designed using monolithic precolumns in microcolumn LC. The monolithic ODS capillary columns were prepared via in situ sol-gel processes. The enrichment efficiency of the monolithic columns was tested by using phthalates as the analytes. The relative standard deviations (n = 6) for the retention time, peak area and peak height were between 0.4 and 1.2%, 0.9 and 5.5% and 0.4 and 3.9%, respectively. The system was linear (R2 > 0.99) within the working sample concentration and sample volume ranges. Comparing to 0.2 microl injection with a typical sample injector, the theoretical plate number of a same separation column was increased by 3-6-fold when the precolumn unit was used for sample injection. The recoveries of the analytes were between 88 and 120%, and the sample volume that could be injected into the system was increased up to 5000-fold. The limits of detection were improved by more than 2000-fold and were between 0.21 and 0.87 ng ml(-1) even with a UV absorbance detector. This system was applied to the determination of phthalates contained in laboratory distilled water and tap water samples.

Chromatography, Liquid↗

Separation of benzene and deuterated benzenes by reversed-phase and recycle liquid chromatography using monolithic capillary columns.

An alternate pumping-recycle system utilizing a commercially available low dead-volume switching valve was developed for microcolumn LC. The recycle system had two separation columns, and the dead volume of the recycling lines was kept to a minimum by avoiding passage of the sample through the pump chamber, sample injector, and the normal path length of a conventional UV detector. The drawback of the high total back pressure caused by the second column that is placed after the detector was overcome by on-column detection, and this eliminated the need for a high pressure flow cell. The system was used for the separation of an authentic mixture of benzene, benzene-1,3,5-d3, and benzene-d6. Baseline separation was accomplished after six cycles and the calculated theoretical plate number for benzene was 230,000. It was observed that the theoretical plate number (N) increased linearly with increasing number of cycles, and the N per unit time increased with increasing inlet pressure. The separation conditions were optimized and the separation of benzene and benzene-d6 was accomplished within 75 min at 2.5 MPa inlet pressure.

Journal Article↗

Cyclodextrin-aided determination of iodate and bromate in drinking water by microcolumn ion chromatography with precolumn enrichment.

A selective and simple method for the determination of iodate (IO3-) and bromate (BrO3-) by microcolumn ion chromatography (IC) is presented. In this study, IO3- and BrO3- were determined as IBr2- and tribromide (Br3-), respectively, via a postcolumn reaction with bromide (Br) under acidic conditions with the aid of alpha-cyclodextrin (alpha-CD) in microcolumn IC. IO3- and BrO3- were selectively detected by the present method at a wavelength of 253 or 265 nm. The present system achieved good selectivity for IO3- and BrO3- as well as good repeatability under suitable conditions. Precolumn enrichment improved the detection limit, and allowed the determination of BrO3- in bottled water as low as sub microg L(-1) level in microcolumn IC.

Bromates↗

A miniaturized FIA system for the determination of residual chlorine in environmental water samples.

The present study was aimed at developing a portable miniaturized FIA system with a two-electrode based amperometric detector for on-site monitoring of residual chlorine in environmental samples. The electrode potential control and current data collection were conducted with a home-designed potentiostat with a size of 150 x 100 x 40 mm and the weight of 350 g. It was confirmed that the amperometric response increased in proportion to the chlorine concentration up to 5 microg/ml, and the detection limit for chlorine was 0.05 microg/ml. Besides a drastic reduction in the size of the analytical system, such miniaturization achieved the advantages of increased speed, minimal mobile-phase consumption, and high sensitivity. The proposed method was successfully applied to the determination of residual chlorine in samples of pool water and tap water. The results were well agreed with those obtained by the N,N-diethyl-p-phenylenediamine (DPD) photometric method.

Journal Article↗

Indirect detection of halide ions via fluorescence quenching of quinine sulfate in microcolumn ion chromatography.

Halide ions could be visualized via fluorescence quenching in microcolumn ion chromatography. The fluorescence of quinine sulfate, which was contained in an acidic eluent, was quenched by halide ions. The observed fluorescence quenching values increased in this order: iodide, bromide, and chloride. The present detection system was relatively sensitive to halide ions except for fluoride: other anions gave smaller signals than halide ions. The present detection system provided quantitative information, so it could be applied to the determination of chloride in water samples.

Journal Article↗

Split flow and bypass flow systems for monolithic capillary columns in liquid chromatography.

Split flow and bypass flow systems were assembled using Nano Y Connectors with low dead volume commercially available for capillary liquid chromatography (LC). The split ratio could be controlled by changing the dimension of restriction tubing and applied back pressure to the restriction tubing. The split flow system allowed us to use valve injectors and pumps commercially available for capillary LC. The reproducibility of the present split flow system was acceptable. The relative standard deviation for six successive measurements was 0.4% for the retention time, whereas that for the peak height and peak area was 1-3% depending on the analytes. The bypass flow system uses two Nano Y Connectors, where the eluent split at the first Nano Y Connector, which is located in the inlet of the separation column, is merged again into the effluent from the column at the second Nano Y Connector. The bypass flow system could avoid on-column detection and allowed us to use flow cells, leading to an approximate three times improvement in signal-to-noise. The present flow systems were evaluated by using aromatic hydrocarbons and alkylbenzenes as test analytes.

Chromatography, Liquid↗