PubMed Health⌕ Search

Biomedical subjects

Tracy Ross

Publications and source records attributed to Tracy Ross.

3 recordsLinked to original sources

A 17-month evaluation of a chlorine dioxide water treatment system to control Legionella species in a hospital water supply.

OBJECTIVE: To assess the safety and efficacy of a chlorine dioxide water treatment system in controlling Legionella in a hospital water supply. DESIGN: For 17 months following installation of the system, we performed regular water cultures throughout the building, assessed chlorine dioxide and chlorite levels, and monitored metal corrosion. RESULTS: Sites that grew Legionella species decreased from 41% at baseline to 4% (P = .001). L. anisa was the only species recovered and it was found in samples of both hot and cold water. Levels of chlorine dioxide and chlorite were below Environmental Protection Agency (EPA) limits for these chemicals in potable water. Further, enhanced carbon filtration effectively removed the chemicals, even at chlorine dioxide levels of more than twice what was used to treat the water. After 9 months, corrosion of copper test strips exposed to the chlorine dioxide was not higher than that of control strips. During the evaluation period, there were no cases of nosocomial Legionella in the building with the system, whereas there was one case in another building. CONCLUSIONS: Our results indicate that operation of a chlorine dioxide system effectively removed Legionella species from a hospital water supply. Furthermore, we found that the system was safe, as levels of chlorine dioxide and chlorite were below EPA limits. The system did not appear to cause increased corrosion of copper pipes. Our results indicate that chlorine dioxide may hold promise as a solution to the problem of Legionella contamination of hospital water supplies.

Academic Medical Centers↗

Pseudo-outbreak of Mycobacterium fortuitum on a Human Immunodeficiency Virus Ward: transient respiratory tract colonization from a contaminated ice machine.

Infection Control surveillance revealed an abnormally high number of sputum samples growing Mycobacterium fortuitum from a single ward that houses the human immunodeficiency virus service. We investigated the outbreak using a retrospective case-control study and molecular epidemiology. A total of 47 patients were identified with >/=1 sputum sample that grew M. fortuitum. No significant demographic or clinical variables were found to be associated with colonization. Environmental investigation demonstrated that the M. fortuitum isolated from patients was identical to the ice machine isolates by pulsed-field gel electrophoresis. Fortunately, there has been no evidence of progressive pulmonary disease developing in our patients after >/=6 months of follow-up. All cases were thought to represent transient colonization and not infection. The ice machine was disconnected and cleaned successfully with vinegar and then bleach. Only when a 0.5-micrometer filter was installed were no further patients colonized or water cultures found to be positive.

Adult↗

A prospective study to determine whether cover gowns in addition to gloves decrease nosocomial transmission of vancomycin-resistant enterococci in an intensive care unit.

BACKGROUND: Vancomycin-resistant enterococci (VRE) remain a significant nosocomial pathogen. Current guidelines of the Hospital Infection Control Practices Advisory Committee (HICPAC) of the Centers for Disease Control and Prevention (CDC) recommend the use of gowns and gloves for some interactions with VRE-infected or -colonized patients to prevent nosocomial transmission of VRE. OBJECTIVE: To assess the effect of disposable cover gowns on preventing nosocomial transmission of VRE. DESIGN AND SETTING: Prospective study in a 16-bed medical intensive care unit of a university teaching hospital. PATIENTS: All patients who were at risk to acquire VRE, were admitted to the intensive care unit from August 1998 to January 1999, and had at least two perirectal cultures were included in the analysis of VRE acquisition. INTERVENTION: VRE isolation precautions were changed from gowns and gloves to gloves alone. MAIN OUTCOME risk factors for VRE acquisition. RESULTS: The VRE acquisition rate was 1.80 cases per 100 days at risk in the gown and gloves period compared with 3.78 in the gloves only period (P = .04). In a proportional hazards model adjusted for length of stay, gloves only precautions with a hazard ratio of 2.5 (P = .02; 95% confidence interval, 1.2 to 5.3) were the only independent risk factor for VRE acquisition. CONCLUSION: Our data lend support to current HICPAC recommendations for the use of cover gowns to decrease nosocomial transmission of VRE.

Baltimore↗