PubMed Health⌕ Search

Biomedical subjects

U Hädinger

Publications and source records attributed to U Hädinger.

4 recordsLinked to original sources

Stereotactic radiotherapy of targets in the lung and liver.

BACKGROUND: Stereotactic irradiation of extracranial targets offers a non-invasive treatment modality for patients with localized tumors, which are not amenable for surgery or other invasive approaches because of age or impaired medical condition. The purpose of the study was the evaluation of the method to achieve local control of irradiated targets in relation to treatment toxicity. PATIENTS AND METHODS: Irradiation was performed as hypofractionated treatment in three fractions of 10 Gy each, normalized to the PTV enclosing 65% isodose with patient fixation in a stereotactic body frame. The isocenter was localized by stereotactic coordinates. Targets were circumscribed tumors in the lung (n = 27) and liver (n = 24) not amenable for other treatment modalities: primary lung cancer (n = 12), local recurrences of lung cancer (n = 4), lung metastases (n = 11), liver metastases (n = 23) and one cholangiocellular carcinoma. Median CTV/PTV for targets in the lung was 57/113 cm3 (min/max 5-277 cm3/17-343 cm3) and for targets in the liver 50/102 cm3 (min/max 9-516 cm3/42-772 cm3). Median follow-up for targets in the lung was 8 months (2-33) and 9 months (2-28) for liver targets. Local control was defined as complete or partial remission and stable disease, measured by repeated CT scans after 6 weeks and in 3 months intervals. Treatment toxicity was evaluated according to the WHO score. RESULTS: Crude local control was 85% for pulmonary targets and 83% for hepatic targets. Actuarial local control after 1 and 2 years was 76% and 76% for lung tumors and 76% and 61% for liver tumors. Actuarial overall patient survival was 48% after 1 year and 21% after 2 years for targets in the lung and 71% and 43% for targets in the liver. No acute grade 3-5 side effects were observed. Serious late toxicity occurred in two patients: a chronic ulceration of the esophagus at a target close to the mediastinum after 3 months (grade 3) and fatal bleeding from the pulmonary artery after 9 months (grade 5) in a previously irradiated patient. It remained unclear, whether the bleeding was a side effect of irradiation or due to tumor infiltration. CONCLUSION: Hypofractionated stereotactic irradiation of targets in the lung and liver is a locally effective treatment with actuarial local control rates of 76% after 1 year and 61-76% after 2 years without relevant acute toxicity. Severe late toxicity did not occur, if targets close to the mediastinum were avoided.

Adenocarcinoma↗

Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame.

BACKGROUND AND PURPOSE: Evaluation of set-up accuracy and analysis of target reproducibility in the stereotactic body frame (SBF), designed by Blomgren and Lax from Karolinska Hospital, Stockholm. Different types of targets were analyzed for the risk of target deviation. The correlation of target deviation to bony structures was analyzed to evaluate the value of bones as reference structures for isocenter verification. MATERIALS AND METHODS: Thirty patients with 32 targets were treated in the SBF for primary or metastatic peripheral lung cancer, liver metastases, abdominal and pelvic tumor recurrences or bone metastases. Set-up accuracy and target mobility were evaluated by CT-simulation and port films. The contours of the target at isocenter level, bony structures and body outline were compared by matching the CT-slices for treatment planning and simulation using the stereotactic coordinates of the SBF as external reference system. The matching procedure was performed by using a 3D treatment planning program. RESULTS: Set-up accuracy represented by bony structures revealed standard deviations (SD) of 3.5 mm in longitudinal, 2.2 mm in anterior-posterior and 3.9 mm in lateral directions. Target reproducibility showed a SD of 4.4 mm in longitudinal, 3.4 mm ap and 3.3 mm in lateral direction prior to correction. Correlation of target deviation to bones ranged from 33% (soft tissue targets) to 100% (bones). CONCLUSION: A security margin of 5 mm for PTV definition is sufficient, if CT simulation is performed prior to each treatment to correct larger target deviations or set-up errors. Isocenter verification relative to bony structures is only safe for bony targets but not for soft tissue targets.

Adult↗

Three dimensional variability in patient positioning using bite block immobilization in 3D-conformal radiation treatment for ENT-tumors.

BACKGROUND AND PURPOSE: The aim of this prospective study was to analyze the three-dimensional (3D) reproducibility of the isocenter position and of patient positioning with the use of bite block immobilization by means of a simple verification procedure for a complex beam arrangement applied for ENT-tumors. MATERIALS AND METHODS: We analyzed the positioning data of 29 consecutive patients treated for ENT-tumors at the Department of Radiotherapy and Oncology of the University of Wurzburg. A total of 136 treatment sessions were analyzed. Patients were positioned and immobilized using an individualized bite block system and a head and neck support. A complex beam arrangement was applied combining two offset rotational and two oblique wedge fields on a 5 MV linear accelerator. Orthogonal verification films were taken once weekly. Four to six film pairs per patient were obtained (during 4-6 weeks) with a mean number of 4.7 film pairs per patient. These were compared to the corresponding orthogonal simulator films taken during primary simulation. Deviations of the verified isocenter from the isocenter on the simulator film were measured and analyzed in three dimensions in terms of overall, systematic and random categories. A 3D-deviation vector was calculated from these 3D data as well as a 2D-deviation vector (for comparison with literature data) from the lateral verification films. RESULTS: The overall setup deviation showed standard deviations (SD) of 2.5, 2.7 and 3.1 mm along the cranio-caudal, anterior-posterior and medio-lateral axes, respectively. The random component ranged from SD 1.9 to 2.1 mm and the systematic component ranged from SD 1.8 to 2.2 mm. The mean length of the 3D-vector was 3.1 mm for the systematic as well as the random component. Ninety percent of 3D systematic and random deviations were less than 5 mm. The mean length of the 2D-vector was 2.4 mm for the random component and 2.2 mm for the systematic component. Ninety percent of 2D-random and systematic variations were less than 4 mm. CONCLUSIONS: The presented individualized bite block immobilization device provides an accurate and reproducible patient positioning for 3D-conformal radiation therapy in the head and neck. Random and systematic deviations in each of the three directions are in the range of +/-4 mm (2 SD, comprising 95% of the deviations) and are within the range or even less than deviations described for most thermoplastic or PVC-mask fixation devices. These deviations should be taken into account during definition of planning target volume in head and neck tumors.

Head and Neck Neoplasms↗