PubMed Health⌕ Search

Biomedical subjects

U Joseph Schoepf

Publications and source records attributed to U Joseph Schoepf.

11 recordsLinked to original sources

Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT.

Multi-detector-row CT angiography (CTA) is a new technology that allows for non-invasive investigation of coronary atherosclerosis in patients. The relation between the morphology of atherosclerotic plaques assessed by CTA and histopathology is unknown. We investigated 11 human cadaver heart specimens. A mixture of methylcellulose and CT contrast media was injected into the coronary arteries to achieve in-vivo-like contrast enhancement within the coronary artery lumen. The morphologic pattern of atherosclerotic lesions found on CTA images and the tissue attenuation of non-calcified plaques were determined. After CTA imaging, atherosclerotic lesions in the coronary arteries were macroscopically identified and characterized histopathologically according to American Heart Association criteria. A total of 50 and 40 lesions were found macroscopically and by CTA, respectively. Thirty-three lesions could have been compared directly. The sensitivity of CTA compared with macroscopic detection of atheromas, fibroatheromas, fibrocalcified, and calcified lesions was 73, 70, 86, and 100%, respectively. The mean CT attenuation of predominantly lipid-rich and fibrous-rich plaques was significantly different (47+/-9 and 104+/-28 HU, respectively; p<0.01). Atherosclerotic coronary plaques detected by CTA may represent different stages of coronary atherosclerosis. The tissue attenuation of non-calcified plaques may allow for assessment of their predominant component.

Adult↗

Multislice CT angiography.

The introduction of multislice CT into clinical radiology constitutes a quantum leap that significantly widens the scope of vascular CT imaging. The advances over conventional spiral CT have been quantitative, mainly in terms of increased image acquisition speed which provides unprecedented volume coverage and spatial resolution. Moreover, significant technical innovations, such as cardiac scanning capabilities, have brought about a qualitative shift towards applications that were thought to be beyond the scope of CT imaging. This way multislice CT offers a wealth of new opportunities for quickly and accurately diagnosing suspected vascular disease in all organ systems; however, as we move towards faster and faster image acquisition techniques, we are also facing new challenges that require development of novel strategies in order to take full advantage of the increased capabilities of multislice CT in its current form and future generations of CT scanners.

Angiography↗

Multidetector-row CT of the heart.

Despite worldwide efforts aimed at primary and secondary prevention, heart disease is still the leading cause of death in the western world. There is great interest in developing tools for noninvasive assessment of the presence and degree of coronary artery disease. The advent of multidetector-row CT allows high-resolution volume coverage of the entire thorax and motion-free imaging of the heart and adjacent vessels within one breathhold. An exciting application with significant potential for cardiac risk stratification, which may overcome the obvious limitations of coronary calcium imaging in the future, is the use of the cross-sectional nature of contrast-enhanced multidetector-row CT coronary angiography for assessment of total coronary artery plaque burden.

Angiography↗

Advances in cardiac imaging with 16-section CT systems.

RATIONALE AND OBJECTIVES: The authors present advances in electrocardiographically (ECG) gated cardiac spiral scanning with recently introduced 16-section computed tomographic (CT) equipment. MATERIALS AND METHODS: The authors discuss the technical principles of ECG-gated cardiac scanning. They give an overview on system properties and on the detector design. They describe ECG-gated scan- and image-reconstruction techniques and ECG-controlled dose modulation ("ECG pulsing") for a reduction of the patient dose. They discuss key parameters for image quality and present simulation and phantom studies and they give preliminary values for the patient dose. RESULTS: An extension of the adaptive cardiac volume reconstruction for ECG-gated spiral CT provides adequate image quality for up to 16 sections. With the smallest reconstructed section width (about 0.83 mm) and overlapping image reconstruction, cylindrical holes 0.6-0.7 mm in diameter can be resolved in a transverse resolution phantom independent of the heart rate. For coronary CT angiography, the influence of transverse resolution is most pronounced for coronary segments that are only slightly tilted relative to the scan plane. In this case, visualization of stents and plaques is considerably improved with 1.0-mm or smaller section width. For 0.42-second gantry rotation time, temporal resolution reaches its optimum (105 msec) at a heart rate of 81 beats per minute. Effective patient dose for the standard protocols recommended by the manufacturer ranges from 0.45 mSv (male) for ECG-triggered calcium scoring to 7.1 mSv (male) for high-resolution ECG-gated coronary CT angiography. With ECG pulsing, the dose is reduced by 30%-50% depending on the patient's heart rate. CONCLUSION: Clinical experience will be needed to evaluate fully the potential of 16-section technology for cardiac imaging.

Artifacts↗

Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT.

PURPOSE: To compare different reconstruction thicknesses of thin-collimation multi-detector row spiral computed tomographic (CT) data sets of the chest for the detection of subsegmental pulmonary emboli. MATERIALS AND METHODS: A multi-detector row spiral CT protocol for the diagnosis of pulmonary embolism was used that consisted of scanning the entire chest with 1-mm collimation within one breath hold. In 17 patients with central pulmonary embolism, the raw data were used to perform reconstructions with 1-mm, 2-mm, and 3-mm section thicknesses. For each set of images, each subsegmental artery was independently graded by three radiologists as open, containing emboli, or indeterminate. RESULTS: For the rate of detection of emboli in subsegmental pulmonary arteries, use of the 1-mm section width yielded an average increase of 40% when compared with the use of 3-mm-thick sections (P <.001) and of 14% when compared with the use of 2-mm-thick sections (P =.001). With the use of 1-mm sections versus 3-mm sections, the number of indeterminate cases decreased by 70% (P =.001). Interrater agreement was substantially better with the use of 1-mm and 2-mm sections than with the use of 3-mm sections. CONCLUSION: For the diagnosis of subsegmental pulmonary emboli at multi-detector row CT, the use of 1-mm section widths results in substantially higher detection rates and greater agreement between different readers than the use of thicker sections.

Adult↗

Coronary artery calcium: absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies.

PURPOSE: (a) To determine the accuracy of multi-detector row computed tomography (CT) in the measurement of the calcium concentration in a cardiac CT calibration phantom and (b) to assess the correlation of a traditional 3-mm section width CT coronary screening protocol and a 1.25-mm section width CT angiography imaging protocol in the quantification of the absolute mass of coronary calcium in patients who underwent both coronary screening and CT angiography with a multi-detector row CT scanner. MATERIALS AND METHODS: A heart phantom containing calcified cylinders was scanned to determine calibration factors and absolute calcium mass. In 50 patients, the variability (value 1 - value 2/mean value 1 - value 2), limit of agreement (+/-2SD value 1 - value 2), and systematic error (mean value 1 - value 2) of the total amount of coronary calcium calculated at traditional 3-mm section width CT and at 1.25-mm section width CT angiography were determined. RESULTS: The correlation coefficient between the 3-mm section width, nonenhanced protocol and the 1.25-mm section width CT angiography protocol was very high (r = 0.977) and the mean variability was low (19.7%) for the absolute mass. There was a systematic error of -6.7 mg and a limit of agreement between 45.0 mg and -58.5 mg. CONCLUSION: Use of the mass quantification algorithm in combination with a calibration phantom allows accurate quantification of coronary calcium. Measurements of calcium mass obtained at 1.25-mm section width CT angiography have the best agreement with those obtained at the traditional 3-mm section width imaging protocol.

Algorithms↗

Detection of coronary artery stenoses with multislice helical CT angiography.

OBJECTIVES: The authors compared multislice CT angiography and selective angiography for the assessment of coronary artery disease. METHODS: In 28 patients, the presence and degree of coronary artery stenoses were determined in coronary segments prepared with beta-blocker for good image quality with multislice CT. RESULTS: In 187 coronary artery segments, sensitivity, specificity, and negative predictive value for the detection of stenoses >50% with multislice CT angiography were 81%, 90%, and 97%, respectively. The agreement for determining the degree of stenoses with multislice CT angiography and selective coronary angiography was only moderate (kappa = 0.58). CONCLUSIONS: Because of the limited spatial resolution, it is not possible with multislice CT angiography to determine the degree the coronary artery stenoses precisely. However, the high negative predictive value indicates that multislice CT may be a suitable tool to reliably rule out coronary artery disease.

Aged↗