PubMed Health⌕ Search

PubMed · 12942298

Multislice CT angiography.

Abstract

The introduction of multislice CT into clinical radiology constitutes a quantum leap that significantly widens the scope of vascular CT imaging. The advances over conventional spiral CT have been quantitative, mainly in terms of increased image acquisition speed which provides unprecedented volume coverage and spatial resolution. Moreover, significant technical innovations, such as cardiac scanning capabilities, have brought about a qualitative shift towards applications that were thought to be beyond the scope of CT imaging. This way multislice CT offers a wealth of new opportunities for quickly and accurately diagnosing suspected vascular disease in all organ systems; however, as we move towards faster and faster image acquisition techniques, we are also facing new challenges that require development of novel strategies in order to take full advantage of the increased capabilities of multislice CT in its current form and future generations of CT scanners.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Joseph Schoepf, Christoph R Becker, Lars K Hofmann, Marco Das, Thomas Flohr, Bernd M Ohnesorge, Bernhard Baumert, Joshua Rolnick, Jean M Allen, Vassilios Raptopoulos. 2003-02-26. Multislice CT angiography.. https://doi.org/10.1007/s00330-003-1842-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of predictive values of two diagnostic tests from the same sample of subjects using weighted least squares.

Screening and diagnostic tests are important in disease prevention or control. The predictive values of positive and negative (PPV and NPV) test results are two of four operational characteristics of a screening test. We review an existing method based on the generalized estimating equation (GEE) methodology for comparing predictive values from the same sample of subjects and propose two Wald test statistics derived from the weighted least squares (WLS) method for the analysis of categorical data. Using these results, we propose sample size calculation formulae for this problem. Simulation studies are conducted to compare the performances of the two Wald test statistics (one based on the difference of two PPVs or NPVs, another based on the logarithm of the ratio of two PPVs or NPVs) and the score/Wald test statistic derived from GEE. We recommend using the difference-based WLS approach.

Angiography↗

Effects of iodinated contrast media on blood and endothelium.

The aim of the study was to assess the effects of iodinated contrast media on blood components and endothelium based on experimental and clinical studies and to produce clinically relevant guidelines for reducing thrombotic and hematologic complications following the intravascular use of contrast media. A report was drafted after review of the literature and discussions among the members of the Contrast Media Safety Committee of the European Society of Urogenital Radiology. The final report was produced following discussion at the 12th European Symposium on Urogenital Radiology in Ljubljana, Slovenia (2005). Experimental data indicate that all iodinated contrast media produce an anticoagulant effect and that this effect is greater with ionic contrast media. Several of the in vitro and experimental in vivo studies on haematological effects of contrast media have not been confirmed by clinical studies. Low- or iso-osmolar contrast media should be used for diagnostic and interventional angiographic procedures, including phlebography. Meticulous angiographic technique is the most important factor for reducing the thrombotic complications associated with angiographic procedures. Drugs and interventional devices that decrease the risk of thromboembolic complications during interventional procedures minimize the importance of the effects of contrast media.

Angiography↗

Buckling test as a new approach to testing flexural rigidities of angiographic catheters.

The general design of catheters is bound by many needs. Angiographic catheters must be rigid enough to be torquable and to maintain lumen structural integrity, but also flexible enough to bend with the curves of a blood vessel. They should cause minimal tissue damage; avoid biocompatibility-related complications, and be reliable over time. This study proposes a new testing approach to clearly identify the flexural rigidity of catheters by using a buckling test to evaluate the peak compressive load. This study also tests several angiographic catheters for axial and torsional rigidity. Seven different catheters used for short-term procedures, with and without reinforcement and of various sizes, were evaluated as a preliminary evaluation of test methods for future in vitro testing of catheters; it was found that the buckling test works very well and provides repeatable results.

Angiography↗