PubMed Health⌕ Search

Biomedical subjects

U Leder

Publications and source records attributed to U Leder.

31 records · Page 2Linked to original sources

[Late fields in magnetcardiography and late potentials in electrocardiography after acute myocardial infarction].

UNLABELLED: A high specificity and a high positive prediction has been reached in risk stratification for a sudden cardiac death after acute myocardial infarction (AMI) by combining multiple methods. But sensitivity and negative prediction are still not satisfying. There are the same physiological processes underlying magnetocardiography (MCG) and electrocardiography (ECG). Nevertheless, the signals in each method contain different information. METHODS: We studied the cardiac magnetic fields in 50 patients after AMI and in 32 probands and calculated the magnetic late field (LF), according to Simsons late potential (LP) analysis. We defined normal values, according to the 95% confidence interval of the probands (QRS < =97 ms, RMS > = 0. 6, LAS < 25 ms). RESULTS: We compared the results of LF and LP analysis regarding pathologic-nonpathologic and found 76% of the patients with the same results in both methods. Four patients had magnetic signals with low amplitude in the ST segment in contrast to the ECG result, while 6 patients with a "LP positive" diagnosis based on RMS and LAS only, did not show LF. In addition, we have found the magnetic QRS complex to be shorter than the electrical one. DISCUSSION: In general, the results of LF measurement are similar to the ones of LP measurement. Presumably, there are intracardial currents, which are not detectable by ECG. Further studies are needed to evaluate the prognostic value in patients at high risk for cardiac arrhythmias.

Adult↗

Application of high-order boundary elements to the electrocardiographic inverse problem.

Eight-noded quadrilateral boundary elements are applied to the electrocardiographic inverse problem as an example for high-order boundary elements. It is shown that the choice of the shape functions used for approximation of the potentials has a remarkable influence on the solution obtained if the number of electrodes is smaller than the number of primary source points (under-determined equation system). Three different formulations are investigated considering a concentric spheres problem where an analytic solution is available: (a) the isoparametric formulation; (b) the quasi-first-order formulation; and (c) the pseudo-subparametric formulation as a new method. In a second step the pseudo-subparametric formulation (which provided the best results in the test problem) is applied to real word data. The transmembrane potential pattern of a 40 years old female suffering from severe heart failure and ventricular tachycardia after large anterior wall myocardial infarction is reconstructed for one time instant. Furthermore, an algorithm for the calculation of the transfer matrix is presented which avoids restrictions to the boundary element mesh caused by the placement of the electrodes.

Adult↗

Source localization in an inhomogeneous physical thorax phantom.

The influence of lung inhomogeneities on focal source localizations in electrocardiography (ECG) and magnetocardiography (MCG) is investigated. A realistically shaped physical thorax phantom with cylindrical lung inhomogeneities is used for electric and magnetic measurements. The lungs are modelled with a special ionic exchange membrane which allows different conductivity compartments without influencing the free ionic current flow. The dipolar current sources are composed of platinum wire and located at different depths and directions between the lung inhomogeneities. We localized the current dipoles with different boundary element method (BEM) models, based on electrical data and simultaneous electrical and magnetic data. Our results indicate the possibility of superadditive information gain by combining electrical and magnetic data for source reconstructions. We found a significant influence of the inhomogeneities on both the calculated source location and the calculated source strength. Mislocalizations of up to 16 mm and wrong dipole strengths of up to 52% were obtained when the lung inhomogeneities were not taken into account for source localization. Dipoles parallel to the lungs showed a larger localization error in depth than dipoles perpendicular to the lungs. We conclude that the incorporation of lung inhomogeneities will improve source localization accuracy in ECG and MCG.

Body Surface Potential Mapping↗

Noninvasive biomagnetic imaging in coronary artery disease based on individual current density maps of the heart.

OBJECTIVE: In this paper we present an attempt at noninvasive imaging of distributed myocardial electrical activity in patients suffering from myocardial infarction and in healthy subjects. Although advances have been made, noninvasive three-dimensional imaging of cardiac electrophysiological activity is still in its infancy and extending our knowledge of cardiac electrophysiological properties may be a valuable guide in the treatment of patients with coronary artery disease. METHODS: Magnetic field mapping data formed the input for an inverse solution that is based on a multiple dipole model. The lead field normalized minimum norm least square criterion was applied to predefined myocardial source geometry. Current density distributions were calculated for the left ventricle during ventricular depolarization. Images from two patients with previous myocardial infarction were compared to images from two healthy subjects. RESULTS: Low regional and global current density was found in the infarction patients. Regions of low current density corresponded to infarcted segments. The images of the healthy subjects displayed less marked areas of low current density. CONCLUSION: The proposed multiple dipole model may be able to distinguish viable from scarred myocardium. A prospective clinical study should be undertaken to investigate the spatial resolution and the diagnostic performance of this method.

Body Surface Potential Mapping↗

MCG simulations of myocardial infarctions with a realistic heart-torso model.

Data from simulations of the anterior myocardial infarction (AMI) and inferior myocardial infarction (IMI) are presented. One infarct located in the anterior section of the left ventricle and a second one in the inferior wall of the left ventricle were modeled. A high-resolution finite element model of a heart and torso was used in this study. Differences in the normal and infarcted fields were computed. Our data suggest that the infarcted region contribution to the total magnetic field can be accounted for by an equivalent current dipole. It might also be possible to detect an infarct from these difference fields constructed for different cases of myocardial infarction. More simulations are needed to determine the relations between infarct sizes and locations and magnetic fields. These relations might then be used to detect various cases of myocardial infarction.

Biophysical Phenomena↗

MCG simulations with a realistic heart-torso model.

Magnetocardiograms (MCG's) simulated with a high-resolution heart-torso model of an adult subject were compared with measured MCG's acquired from the same individual. An exact match of the measured and simulated MCG's was not found due to the uncertainties in tissue conductivities and cardiac source positions. However, general features of the measured MCG's were reasonably represented by the simulated data for most, but not all of the channels. This suggests that the model accounts for the most important mechanisms underlying the genesis of MCG's and may be useful for cardiac magnetic field modeling under normal and diseased states. MCG's were simulated with a realistic finite-element heart-torso model constructed from segmented magnetic resonance images with 19 different tissue types identified. A finite-element model was developed from the segmented images. The model consists of 2.51 million brick-shaped elements and 2.58 million nodes, and has a voxel resolution of 1.56 x 1.56 x 3 mm. Current distributions inside the torso and the magnetic fields and MCG's at the gradiometer coil locations were computed. MCG's were measured with a Philips twin Dewar first-order gradiometer SQUID-system consisting of 31 channels in one tank and 19 channels in the other.

Adult↗

[Afterload and blood pressure amplitude in dilated cardiomyopathy].

The beat-to-beat variability of the diastolic blood pressure induces small variations in the afterload of the left ventricle. These variations influence myocardial contractility, and thus blood pressure amplitude. We assessed the interdependence of blood pressure and changes in the afterload. We continuously recorded blood pressure (duration 200 s, at rest) in 20 patients with dilated cardiomyopathy (ejection fraction 32 +/- 13%, left ventricular diameter 67 +/- 8 mm) and in 20 healthy volunteers. Interbeat intervals, diastolic pressures, systolic pressure amplitudes and mean slopes of systolic pressure amplitudes were measured. Correlation coefficients (r) were calculated to assess the interdependence of blood pressure amplitudes/mean systolic slopes and the preceding diastolic pressures/interbeat intervals, respectively. In healthy volunteers we found a strong interdependence between blood pressure amplitude and the preceding diastolic pressures (r = 0.62 +/- 0.21 and 0.47 +/- 0.22). Higher diastolic pressures were followed by higher blood pressure amplitudes, and by steeper slopes of the systolic peaks. In patients with dilated cardiomyopathy, such interdependence was significantly lower (r = 0.33 +/- 22 and r = 0.28 +/- 0.35), and in patients with severely reduced left ventricular function (ejection fraction < 32%) was only marginal (r = 0.23 +/- 0.27 and 0.21 +/- 0.44, respectively). The forces of the isovolumetric contraction necessary to initiate the ejection phase of the left ventricle depend on the afterload, i.e. on the diastolic pressure. The responses of amplitude and slope of the systolic blood pressure to small changes in the afterload make it possible to assess left ventricular contractility. The latter is impaired in dilated cardiomyopathy.

Adult↗