PubMed HealthSearch

Biomedical subjects

U Moström

Publications and source records attributed to U Moström.

5 recordsLinked to original sources

The rhesus monkey as a model for studies of pregnancy induced changes in metoprolol metabolism.

Five pregnant Rhesus monkeys were catheterized in the hepatic and femoral veins. They were simultaneously given 168 or 176 micrograms of 3H-metoprolol intravenously, and 9 mg of metoprolol per kg body weight orally. The same procedure was repeated a few months after delivery. Analyses of the unlabelled drug in blood were made by gas-chromatography and of the 3H-labelled metoprolol, by liquid scintillation. The apparent volume of distribution as well as the terminal half-lives of metoprolol were in the same range during pregnancy and in non-pregnancy. The oral bioavailability of metoprolol was lower (6-22%) during pregnancy than in non-pregnancy (9-49%). The apparent oral clearance and the intrinsic hepatic clearance were in a similar range although there was a greater variation in the intrinsic clearance values. The former clearance estimate was lower in the non-pregnant state only for three of the five animals. The systemic clearance varied very little and was in the same range during pregnancy and in non-pregnancy. The changes in apparent oral clearance and in oral bioavailability of metoprolol between the pregnant and non-pregnant Rhesus monkey are similar to the changes observed in pregnant women, although the absolute values are different.

Administration, Oral

Technique of cervical myelography with metrizamide.

A technically simple modification of the prone posture technique for cervical myelography with use of metrizamide (Amipaque) after lumbar puncture is described. The procedure is well tolerated by the patients.

Humans

Spatial distribution of dose in computed tomography with special reference to thin-slice techniques.

The spatial dose distribution in a cylindrical polystyrene phantom with a diameter of 200 mm was measured for seven computed tomography (CT) scanners. The measurements were performed in the head mode and mainly for narrow slices in the range 1.5 to 4 mm. Both radial and axial dose profiles were measured and the dose distribution for multiple-scan procedures was calculated. The ratio between the surface and centre doses for a single scan varied between the extremes of 1.8 and 4.3 and was generally higher for narrow than for wide slices. With multiple nominally contiguous scans the difference in absorbed dose between surface and centre locations in the object decreased, on account of scattered radiation. The CT dose index for centre locations varied considerably between the tested scanners, with a range from 5.6 to 27.2 mGy per nominal 100 mAs. For a simulated multiple-scan procedure, comparable to a CT examination of the orbits, the multiple-scan average dose varied between 4.3 and 16.4 mGy per nominal 100 mAs.

Body Burden