Experiences and expectations of a novel X-ray microsource with focusing mirror. I.

Data are presented from a novel microfocus X-ray generator installed with a choice of ellipsoidal specularly reflecting mirrors. Diffraction data from proteins show the useful flux from this low-power device to be approaching equivalence with that from many far more powerful generators. Intensity measurements show that for small crystals the brilliance is now restricted by the performance of the mirror, which appears to be limited by imperfections in the figure of its surface rather than by a low reflectivity. Suitable choices of ellipsoidal mirror enable the size and divergence of the X-ray beam to be altered readily to match the different requirements of successive samples and appropriate designs are proposed. Alternative types of mirror are expected to be advantageous, especially for the smallest crystals. For crystals of sizes 300 microm or less, which need a small well collimated beam with low divergence, the output from this X-ray tube running at 24 W provides a usable flux similar to that available from rotating-anode generators. The relative performance of this tube and mirror combination becomes increasingly advantageous with the study of ever-smaller crystals.

Crystallography, X-Ray↗

A neutron television camera detector.

The system under development has a large counting rate capability; this is extremely important where the total background count exceeds the total counts in the signals of interest. Its spatial resolution is of the order of one mm, which is perfectly adequate for neutron work, while the screen size of 400 mm is reasonable. The main limitation of the system is its limited counting efficiency, and this is directly attributable to the optical self-absorption of the neutron phosphor. Any newly developed transparent phosphor with the same light output would immediately change the situation. The success of the electronics hardware in reducing random noise is demonstrated in Figure 3, which shows in the bottom trace the live video output when the input to the system is a grey-scale test chart. The top trace is the output after the image has been digitally integrated. Figures 4 and 5 show the monitor outputs of the see articles x-ray system with a "still" diffraction pattern of a crystal of GPD (glyceraldehyde-3-phosphate dehydrogenase). Figure 4 is a photograph of the "live" video display, and Figure 5 is the digitally summed image. All coherent noise in the system, i.e., all noise synchronized with the TV scans has to be kept lower than the first bit threshold. However, this requirement can be relaxed when dealing with diffraction patterns, such as those from single crystals, for which a local background is subtracted from the pattern.

Neutrons↗