Abstract

The system under development has a large counting rate capability; this is extremely important where the total background count exceeds the total counts in the signals of interest. Its spatial resolution is of the order of one mm, which is perfectly adequate for neutron work, while the screen size of 400 mm is reasonable. The main limitation of the system is its limited counting efficiency, and this is directly attributable to the optical self-absorption of the neutron phosphor. Any newly developed transparent phosphor with the same light output would immediately change the situation. The success of the electronics hardware in reducing random noise is demonstrated in Figure 3, which shows in the bottom trace the live video output when the input to the system is a grey-scale test chart. The top trace is the output after the image has been digitally integrated. Figures 4 and 5 show the monitor outputs of the see articles x-ray system with a "still" diffraction pattern of a crystal of GPD (glyceraldehyde-3-phosphate dehydrogenase). Figure 4 is a photograph of the "live" video display, and Figure 5 is the digitally summed image. All coherent noise in the system, i.e., all noise synchronized with the TV scans has to be kept lower than the first bit threshold. However, this requirement can be relaxed when dealing with diffraction patterns, such as those from single crystals, for which a local background is subtracted from the pattern.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U W Arndt, D J Gilmore. 1976. A neutron television camera detector.. https://pubmed.ncbi.nlm.nih.gov/963582/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Nuclear data for production of the therapeutic radionuclides 32P, 64Cu, 67Cu, 89Sr, 90Y and 153Sm via the (n,p) reaction: evaluation of excitation function and its validation via integral cross-section measurement using a 14 MeV d(Be) neutron source.

Nuclear data for production of the therapeutic radionuclides 32P, 64Cu, 67Cu, 89Sr, 90Y and 153Sm via (n,p) reactions on the target nuclei 32S, 64Zn, 67Zn, 89Y, (90)Zr and 153Eu, respectively, are discussed. The available information on each excitation function was analysed. From the recommended data set for each reaction the average integrated cross section for a standard 14 MeV d(Be) neutron field was deduced. The spectrum-averaged cross section was also measured experimentally. A comparison of the integrated value with the integral measurement served to validate the excitation function within about 15%. A fast neutron source appears to be much more effective than a fission reactor for production of the above-mentioned radionuclides in a no-carrier-added form via the (n,p) process. In particular, the possibility of production of high specific activity 153Sm is discussed.

Neutrons↗

Width of the hexadecane-water interface: a discrepancy resolved.

An existing discrepancy in the determined values of the width of the hexadecane-water interface as determined from X-ray reflection (XR) and recent neutron reflection (NR) measurements has been resolved. The NR-determined width reported here is 6.0 +/- 1.0 Angstroms, which compares extremely well with the XR-determined value of 6.0 +/- 0.2 Angstroms. The origin of the discrepancy has been attributed to the thermal history of the interface rather than sample purity or other technique-dependent reasons.

Neutrons↗