PubMed Health⌕ Search

Biomedical subjects

V Colletti

Publications and source records attributed to V Colletti.

At least 37 records · Page 2Linked to original sources

Iatrogenic impairment of hearing during surgery for acoustic neuroma.

Isolated or combined labyrinthine, neural, and vascular damage account for failure to preserve hearing during removal of acoustic neuromas. However, the specific mechanisms of auditory impairment remain unclear unless surgical maneuvers can be related to peri- and postoperative hearing on the basis of intraoperative monitoring of auditory function.Among the different auditory monitoring techniques, recording of cochlear nerve action potentials (CNAPs) from the intracranial portion of the nerve has proven particularly useful for identifying the mechanisms of iatrogenic auditory injury.The present investigation analyzes intra- and postoperative auditory impairment in relation to surgical steps in a group of 38 subjects with acoustic neuroma (size ranging from 5 to 24 mm) undergoing removal via a retrosigmoid approach.Coagulation close to the cochlear nerve, drilling of the internal auditory canal, and removal of the intrameatal portion of the acoustic neuroma have prove to be the most critical surgical steps in hearing preservation.Changes were correlated with intra- and extrameatal tumor size, the relationship between the internal auditory canal and vestibule, and internal auditory canal enlargement, anatomic involvement of the cochlear nerve, preoperative auditory level, and ABR and ENG test findings.Changes in CNAP morphology and latency are detailed, and mechanisms of injury are analyzed and discussed as a function of these variables.

Journal Article↗

Continuous retrograde monitoring of the facial nerve: preliminary experience during acoustic neuroma surgery.

Continuous electromyographical (EMG) monitoring of the facial nerve is widely used during acoustic tumor surgery. Mechanical stimulation of the facial nerve is capable of eliciting synchronous and asynchronous EMG responses alerting the surgeon to damaging maneuvers performed on the nerve. Mechanical stimulation, however, elicits EMG responses only when the nerve has been injured by the underlying pathology or previous surgical maneuvers, and the technique is sensitive to administration of muscular blockers. In addition, EMG is unable to furnish quantitative information about the damage. The present paper illustrates an alternative technique for intraoperative facial nerve monitoring, that is, the recording of facial nerve antidromic potentials (FNAPs).Eleven subjects operated on by acoustic neuroma surgery via a retrosigmoid approach (tumor sizes ranging from 12 to 28 mm) participated in the investigation. Bipolar electrical stimulation of the marginalis mandibulae was performed to elicit FNAPs. Stimulus intensity ranged from 2 to 6 mA with a delivery rate of 7/second. A silver-wire electrode positioned on the proximal portion of the acoustic-facial bundle was used to record action potentials. Changes in latency and amplitude of FNAPs were analyzed as a function of the main surgical steps. FNAP monitoring provided quantitative real-time information about damaging maneuvers performed on the nerve and allowed prediction of postoperative facial function.

Journal Article↗

Continuous retrograde monitoring of the facial nerve during cerebellopontine angle surgery: normative data.

An alternative technique for the continuous monitoring of the facial nerve, monopolar recording of facial nerve antidromic potentials (FNAPs), on 10 subjects undergoing retrosigmoid vestibular neurectomy for Meniere's disease is described. To elicit FNAPs bipolar electrical stimulation of the marginalis mandibulae was performed. Stimulus intensity ranged from 0 to 10 mA with a delivery rate of 7/second. Antidromic potentials were recorded with a silver wire monopolar electrode positioned intracranially on the proximal portion (root entry zone) of the acoustic-facial bundle. Bipolar recordings with two silver electrodes were also performed from different nerves in the cerebellopontine angle to define the specific origin of the action potentials. FNAP. amplitude increased as a function of stimulus intensity. The average latency was 3.35 milliseconds (range 3.0 to 3.7 ms). Action potentials recorded intracranially during electrical stimulation of the marginal nerve originated specifically from the facial nerve. FNAP recording is therefore a promising technique for the continuous intraoperative monitoring of the facial nerve during cerebellopontine angle surgery.

Journal Article↗

Extrusion of corpora amylacea from the marginal gila at the vestibular root entry zone.

We have studied the vestibular nerve in patents suffering from Meniere' s disease and vascular cross-compression syndrome of the root entry zone due to close contact with the nerve of the antero-inferior cerebellar artery or one of its branches. All patients underwent vestibular neurectomy using the restrosigmoid approach which allows the resection of a relatively long nerve segment. In all the studied vestibular nerves a central and a peripheral zone could be distinguished. In the central zone, a massive accumulation of corpora amylacea (CA) was detected in the cytoplasm of astrocytes. Many CA were seen to protrude from the central nervous system into the pial connective tissue. These structures resembled sessile or predunculated polyps, with a complex system of scissurae at their bases. CA were also found in extracellular location in the pial connective tissue near capillaries, and not wrapped by membranes. Our findings suggest that after their production in astrocytes, CA are transferred into a pial connective tissue across the glial-limiting lamina. Thus, the present results indicate that CA do not merely represent an accumulation of abnormal material, but they could instead be part of a glio-pial system devoted to the clearance of substances from the nervous system.

Adult↗

Utility and safety of parotid gland biopsy in Sjögren's syndrome.

Parotid gland biopsy was performed in 32 female patients affected by suspected Sjögren's syndrome. In all cases histologic findings were in agreement with this diagnosis and in two subjects led us to detect the malignant transformation into lymphoma. None of the patients developed relevant complications. Our study indicates that parotid gland biopsy in Sjögren's syndrome is a safe procedure and may be useful in performing diagnosis.

Adult↗

New perspectives in intraoperative facial nerve monitoring with antidromic potentials.

Electromyographic (EMG) activity recorded from the facial muscles in response to electrical and mechanical stimulation is the most popular method for continuous monitoring of the facial nerve during cerebellopontine-angle surgery. EMG recording is, however, extremely sensitive to the administration of neuromuscular blockers. An alternative technique for the continuous monitoring of the facial nerve [i.e., monopolar recording of facial nerve antidromic potentials (FNAPs)], is described. Ten subjects undergoing retrosigmoid vestibular neurectomy for Meniere's disease and 11 subjects operated on with acoustic neuroma surgery via a retrosigmoid approach (tumor size range, 12-28 mm) participated in the investigation. Bipolar electrical stimulation of the marginalis mandibulae was performed to elicit FNAPs. Stimulus intensity ranged from 0 to 10 mA with a delivery rate of 7/s. Antidromic potentials were recorded with a silver-wire monopolar electrode positioned intracranially on the proximal portion (root entry zone) of the acoustic-facial bundle. Bipolar recordings with two silver electrodes were also performed from the trigeminal and facial nerves in the cerebellopontine angle to define the specific origin of the action potentials. FNAP amplitude increased as a function of stimulus intensity. The average latency was 3.35 ms (range, 3.0-3.7 ms). Action potentials recorded intracranially during electrical stimulation of the marginal nerve originated specifically from the facial nerve. Changes in latency and amplitude of FNAPs were analyzed as a function of the main surgical steps in patients operated on for acoustic neuroma. FNAP monitoring provided quantitative real-time information about damaging maneuvers performed on the nerve and postoperative facial function.

Adult↗

Click-evoked responses from the exposed intracranial portion of the eighth nerve during vestibular nerve section: bipolar and monopolar recordings.

We compare the click-evoked compound action potentials from the exposed intracranial portion of the eighth nerve using bipolar and monopolar recording electrodes in patients undergoing vestibular nerve section. It is assumed that a bipolar recording electrode will only record propagated neural activity in the auditory nerve, whereas a monopolar recording electrode may in addition record electrical activity that is conducted passively to the recording site. The results of the present study confirm that the earliest detectable propagated neural activity in the intracranial portion of the auditory nerve occurs with a latency that is close to that of peak II of the brain-stem auditory evoked potentials, and the results also confirm that the late components in the click-evoked compound action potentials that have been demonstrated previously using the monopolar recording technique represent propagated neural activity in the auditory nerve. The results also indicate that the responses that are recorded by a bipolar recording electrode, when the small tips of which are placed on the eighth nerve when it is relatively dry, represent only small populations of nerve fibers. Even when an attempt is made to align the two tips of a bipolar electrode with the course of the auditory nerve, this type of electrode may record from different populations of nerve fibers.

Acoustic Stimulation↗

Neural conduction velocity of the human auditory nerve: bipolar recordings from the exposed intracranial portion of the eighth nerve during vestibular nerve section.

We measured the conduction velocity of the intracranial portion of the auditory nerve in 3 patients undergoing vestibular nerve section to treat Ménière's disease. The conduction velocity varied from patient to patient, with an average value of 15.1 m/sec. The latency of peak III of the brain-stem auditory evoked potentials (BAEPs) increased by an average of 0.5 msec as a result of exposure of the eighth nerve, and if that increase is assumed to affect the entire length of the auditory nerve (2.6 cm) evenly, then the corrected estimate of conduction velocity would be 22.0 m/sec. Estimates of conduction velocity based on the interpeak latencies of peaks I and II of the BAEP, assuming that peak II is generated by the mid-portion of the intracranial segment of the auditory nerve, yielded similar values of conduction velocities (about 20 m/sec).

Electroencephalography↗

Vestibular Neurectomy and Microvascular Decompression of the Cochlear Nerve in Meniere's Disease.

Vestibular neurectomy (VN) results in a high success rate in the control of vertigo in Meniere's disease, although the subsequent fate of auditory function is fairly unpredictable. The present investigation reports the postoperative results obtained in a group of 30 subjects with a clinical diagnosis of Meniere's disease and vascular cross-compression of cranial nerve VIII. All subjects underwent VN using a retrosigmoid approach, and in half of them microvascular decompression (MVD) of the cochlear nerve with interposition of autogenous muscle was performed at the same time. All patients had complete relief from vertigo. Hearing was significantly improved in the VN-MVD group (46.7% of subjects). In this group tinnitus and aural fullness also improved significantly, with values of 62.6% and 66.6%, respectively.

Journal Article↗

Changes in directly recorded cochlear nerve compound action potentials during acoustic tumor surgery.

Damage to labyrinthine, neural, and vascular structures may possibly account for failure to achieve hearing preservation after removal of small acoustic neuromas. The pathogenesis of auditory impairment is, however, sometimes unclear. Intraoperative monitoring of auditory evoked potentials enables us to study possible correlations between surgical maneuvers and the function of auditory structures and pathways. To this end, simultaneous recording of brainstern auditory evoked potentials and direct cochlear nerve action potentials (CNAPs) was utilized in 14 patients with small (12 to 18 mm) unilateral acoustic neuromas. The latency of the first negative component (N(1)) of the CNAPs proved extremely sensitive in detecting intraoperative auditory damage and was a good predictive index of postoperative auditory outcome. Evaluation of temporal and morphologic CNAP patterns allowed identification of coagulation close to the cochlear nerve, drilling of the internal auditory canal, and removal of the intrameatal portion of the tumor, the most critical steps in hearing preservation. The mechanisms of damage are analyzed and discussed.

Journal Article↗

Stapedotomy with stapedius tendon preservation: technique and long-term results.

From 1975 to 1992, a total of 1459 primary stapedoplasty operations (i.e., stapedectomy, stapedotomy with tendon section, and stapedotomy with tendon preservation) were performed in 1323 subjects at the Ear, Nose, and Throat Department of the University of Verona. Pure-tone audiometry was carried out in all subjects who were operated on and who underwent 6-month and 10-year follow-ups. To evaluate the influence of stapedius tendon preservation on functional outcome, we randomly selected subgroups of patients using the three different stapedioplasty techniques and tested them by multiple-frequency tympanometry, psychoacoustic tuning curves, and speech discrimination in noise. Finally, to assess the effect of prosthesis diameter on middle ear transfer function, we used the electrocochleographic technique and examined the threshold and latency of cochlear nerve compound action potentials recorded during surgery from the round window. The results of this study show that the best auditory performance in otosclerotic subjects is achieved by performing a stapedotomy of 0.7 mm diameter, using a 0.6 wire-Teflon piston, and preserving the stapedius tendon.

Acoustic Impedance Tests↗

Vulnerability of hearing function during acoustic neuroma surgery.

Intraoperative monitoring of auditory evoked potentials reveals possible correlations between surgical maneuvers and the function of auditory structures and pathways in cerebellopontine angle surgery. Direct cochlear nerve action potentials (CNAPS) furnish realtime information on the function of the cochlea and cochlear nerve and were utilized in 14 patients undergoing removal of small (12-18 mm) unilateral acoustic tumors. The latency of the first negative component (N1) of the CNAPs proved extremely sensitive in detecting intraoperative auditory damage and was a good predictive index of postoperative auditory outcome. Evaluation of temporal and morphological CNAP patterns allowed identification of coagulation close to the cochlear nerve, drilling of the internal auditory canal and removal of the intrameatal portion of the tumor as the most critical steps in hearing preservation.

Adult↗

Bipolar recording of the cochlear nerve action potentials during cerebellopontine angle surgery.

A technique of bipolar recording of the cochlear nerve compound action potentials (CAPs) to make identification and preservation of the cochlear nerve easier during cerebellopontine angle surgery is described. Four patients, aged 32 to 65 years, with acoustic tumors smaller than 2 mm and serviceable hearing, participated in the study. To investigate the resolution power of bipolar CAP recordings, a pilot study had been performed in a group of four patients submitted to vestibular neurectomy. Two silver electrodes insulated by Teflon up to the exposed ends were utilized for bipolar recording of the CAPs. They were twisted with each other and the distance between the two electrode tips could be varied from 0.3 to 0.7 mm. Rarefying polarity clicks (31/s) at 100 to 125 dB SPL were utilized as stimuli. Bipolar recording from the eight nerve was extremely selective: a good response was obtained only when the electrode was positioned on the cochlear portion of the eighth nerve. No response was present when the electrode was placed on the vestibular nerve and on the tumor. Frequent probing of tumor and eighth nerve with the bipolar recording electrode during acoustic neuroma removal facilitated the task of identifying the cochlear nerve and allowed its preservation in all patients.

Adult↗

Mechanics of the middle ear in otosclerosis and stapedoplasty.

Seventy-three otosclerotic patients, 138 subjects who had undergone stapes surgery (50 total stapedectomies, 43 stapedotomies with stapedius tendon section and 45 stapedotomies with stapedius tendon preservation) and 70 normal controls were investigated by susceptance multiple frequency tympanometry. The aims were to evaluate the efficiency of this procedure in diagnosing otosclerosis and to assess the resonance properties of middle ears undergoing different types of stapedectomy. Tympanometry was performed using sweep frequencies ranging from 226 to 2,000 Hz for each pressure step of 12.5 daPa (pressure range from -500 to 400 daPa). The resonance frequency of the system was evaluated by identifying the "W" morphology of susceptance tympanograms. The results of the present investigation indicate that stapes surgery abnormally reduces the stiffness of the tympano-ossicular system. This phenomenon is limited by preservation of the stapedius tendon, which confers a significant degree of stiffness on the conductive system.

Acoustic Impedance Tests↗

Electrophysiologic identification of the cochlear nerve fibers during cerebello-pontine angle surgery.

To facilitate identification and preservation of the auditory nerve during cerebello-pontine angle surgery, bipolar recording of cochlear nerve compound action potentials (CNAPs) was performed. Two silver wires insulated with teflon up to the exposed ends were utilized as electrodes. They were twisted together, the distance between the two tips being 1 mm or less. Rarefaction polarity clicks (31/s) ranging from the psychoacoustical threshold to 120 dB pe SPL were used as stimuli. The investigation was performed in three groups of patients. The first group consisted of 9 patients submitted to vestibular neurectomy and 4 patients operated on by microvascular decompression of the eighth nerve. The second group comprised 8 patients with acoustic tumors smaller than 2 mm and serviceable hearing. Postoperative audiometric results in the subjects in the second group were compared with those obtained in well-matched homogeneous controls consisting of patients with acoustic neuroma operated on without the aid of CNAP recording. Bipolar recording from the eighth nerve was extremely selective, a good response being obtained only when positioning the electrode on the cochlear portion of the eighth nerve. During removal of the acoustic neuroma, repeated bipolar probing of the tumor and eighth nerve facilitated the task of distinguishing the cochlear nerve from other nervous structures and from the tumor, and contributed to preserving hearing in most patients.

Action Potentials↗

Investigations in electrophysiology and morphology of the VIII cranial nerve.

The morphological and functional changes of the eighth nerve in patients undergoing cerebello-pontine angle (CPA) surgery are under investigation in the ENT Department of the University of Verona. The main aspects of the research are: ultrastructural examination of the eighth nerve in normals and subjects operated on for vestibular or cochleo-vestibular neurectomy and for acoustic neuroma; monitoring cochlear nerve function during CPA surgery by monopolar and bipolar recording of cochlear nerve action potential (CNAPs). The specific aims of this research are: to acquire information on the pathophysiology of a number of peripheral cochleo-vestibular disorders; to evaluate the role of intraoperative recording of the eighth nerve in preserving hearing.

Evoked Potentials, Auditory↗

Reduced active protection to the cochlea during physical exercise.

The present investigation was designed to evaluate whether dynamic physical exercise is able to modify stapedius reflex (SR) activity and, as a consequence, to influence the amount of temporary threshold shift (TTS). Experimental subjects were 10 normal-hearing male volunteers, aged 27-34 years (mean 30.8). SR parameters in the time-domain were assessed before, during and after submaximal exercise test, performed for 10 min on an ergometer cycle at 50% of maximum work capacity. The same parameters were also investigated in the absence of exercise, at time-matched intervals. In addition, the combined effect of noise and exercise was studied. The outcome of the investigation indicates that dynamic physical exercise depresses the SR and potentiates noise-induced TTS. The mechanisms underlying the present findings are discussed.

Adult↗