PubMed Health⌕ Search

Biomedical subjects

Victor Mor-Avi

Publications and source records attributed to Victor Mor-Avi.

At least 37 records · Page 2Linked to original sources

Ventricular resynchronization by multisite pacing improves myocardial performance in the postoperative single-ventricle patient.

BACKGROUND: Ventricular resynchronization with multisite pacing in heart failure patients results in acute improvement of myocardial performance, but the mechanism is unknown. Our goals were to determine whether multisite pacing results in acute improvement of myocardial performance in postoperative single-ventricle patients, and to elucidate the mechanism by assessing the synchronization of regional ventricular contraction during multisite pacing using real-time three-dimensional echocardiographic imaging. METHODS: Multisite pacing studies were performed in 26 single-ventricle patients (mean age, 28 months; range, 7 days to 11 years) undergoing some form of single-ventricle palliation (stage I Norwood, 4; aortopulmonary shunt, 1; cavopulmonary shunt, 9; Fontan, 8; Fontan revision, 3; valve replacement, 1). Electrocardiogram, blood pressure, mixed-venous oxygen saturation, and three-dimensional echocardiograms (n = 10) were recorded at baseline and during multisite pacing. Data were analyzed to obtain regional volume-time curves for 16 three-dimensional segments of the systemic ventricle. An index of asynchrony was calculated at baseline and during pacing as the standard deviation of all segmental volume-time curves from onset to end of ejection. RESULTS: With multisite pacing performed at a median postoperative day 2 (range, 0 to 9), QRS duration decreased in 24 of 26 patients (93.9 +/- 17.5 versus 71.7 +/- 10.8 ms; p < 0.001); systolic blood pressure increased in 25 of 26 patients (86.3 +/- 20.0 versus 93.8 +/- 20.2 mm Hg; p < 0.001); cardiac index increased in 21 of 22 patients (3.2 +/- 0.8 versus 3.7 +/- 1.0 L x min(-1) x m(-2); p < 0.001); and the index of asynchrony improved in 8 of 10 patients (10.3 +/- 4.8 versus 6.0 +/- 1.4; p < 0.04). CONCLUSIONS: Multisite pacing improves cardiac performance after single-ventricle palliation. Real-time three-dimensional echocardiography demonstrated that multisite pacing improved the synchrony of ventricular contraction.

Cardiac Pacing, Artificial↗

Assessment of left ventricular function with contrast echocardiography.

Echocardiography continues to be the primary noninvasive imaging modality for the assessment of cardiac structure and function because of significant advances in ultrasound imaging technology over the last two decades, yet quantification of the LV function has remained an elusive goal. The introduction of contrast agents has represented a major advance in clinicians' ability to visualize the endocardium and to assess LV function accurately, particularly in patients who have poor acoustic windows. Ongoing and future refinements in imaging technology used with contrast enhancement have placed automated quantification of LV function on the brink of widespread clinical use.

Contrast Media↗

Harmonic imaging for endocardial visualization and myocardial contrast echocardiography during transesophageal echocardiography.

BACKGROUND: Although harmonic imaging (HI) improves endocardial visualization and is necessary for myocardial perfusion imaging, it has yet to be implemented in transesophageal echocardiography. Our goal was to determine whether HI implemented in a prototype transesophageal echocardiography probe improved endocardial visualization and allowed perfusion imaging. METHODS: In 23 patients, fundamental and harmonic images were obtained in the transgastric short-axis (TSAX) and midesophageal 4-chamber views, and reviewed for endocardial visualization by 3 readers blinded to imaging mode. In 14 additional patients, perfusion imaging was performed in the TSAX view during contrast infusion. RESULTS: HI improved overall endocardial visualization, most noticeably in the anterior and lateral segments (P <.004) in the TSAX view, and in the lateral segments (P <.01) in the midesophageal 4-chamber view. The salvage rate was 8.3% in the TSAX view and 12.6% in the midesophageal 4-chamber view. Myocardial perfusion was consistently confirmed in the inferior (86%), posterior (100%), and lateral (79%) segments, but rarely in the septal (21%), anteroseptal (0%), and anterior (14%) segments. CONCLUSION: Use of HI with transesophageal echocardiography improves endorcardial visualization and allows partial assessment of myocardial perfusion.

Coronary Circulation↗

Age dependency of the Tei index of myocardial performance.

Despite its clinical use as a sensitive measure of left ventricular performance, little is known about whether the Tei index is influenced by aging. We determined the Tei index in 141 subjects without cardiovascular disease (age 16-78 years). There were statistically significant variations in ejection time, isovolumic relaxation time, and the Tei index with aging. There was a moderate linear correlation between isovolumic relaxation time and age (r = 0.49, P <.001) and the Tei index and age (r = 0.33, P <.001). This investigation demonstrated that when assessing myocardial performance in patients using this index, age-normalized values should be used.

Adolescent↗

Automated quantitative assessment of wall motion in patients with poor acoustic windows.

BACKGROUND: No technique exists for objective evaluation of left ventricular wall motion in contrast-enhanced images. We tested a new technique for quantification of regional fractional area change using contrast-enhanced power modulation imaging with color kinesis. METHODS: The feasibility of this technique for detecting acute ischemia was first tested in 11 pigs. Next, the accuracy for detecting resting wall-motion abnormalities was determined in 52 patients requiring contrast and compared with conventional interpretation of 2-dimensional images by inexperienced readers. Expert interpretation of 2-dimensional images served as the gold standard. RESULTS: In pigs, coronary occlusion resulted in reversible hypokinesis and reduced regional fractional area change. In patients with poor acoustic windows, this technique's accuracy for quantitative detection of resting wall-motion abnormalities was 86% compared with 81% for conventional interpretation by inexperienced readers (P <.01). CONCLUSIONS: Regional wall motion can be accurately assessed using color-encoded power modulation imaging for patients requiring contrast. This technique may prove a useful diagnostic aid to echocardiographers of varying levels of experience.

Animals↗

The role of still-frame parametric imaging in magnetic resonance assessment of left ventricular wall motion by non-cardiologists.

BACKGROUND: Cardiac magnetic resonance (MR) images are often reviewed by non-cardiologists who are not trained in the interpretation of regional left ventricular (LV) function. We hypothesized that the use of still-frame parametric MR images of wall motion could aid in the assessment of regional LV function. METHODS: Dynamic, electrocardiogram-gated, steady-state free precession (FIESTA) short-axis images were obtained in 6 to 10 slices in 18 consecutive patients. Each loop was used to automatically generate a still-frame image, in which each pixel is assigned a value equal to the amplitude of cyclic variation in local intensity, resulting in higher intensity in pixels that change between blood and tissue during the cardiac cycle. The dynamic images were reviewed by an expert cardiologist who provided gold standard grades for regional wall motion and by four radiologists. Then the radiologists reviewed and graded the same MR images in combination with parametric images. Grades assigned to each segment in the two sessions were compared with the gold standard. RESULTS: According to expert interpretation, 6 patients had normal wall motion, and 12 had wall motion abnormalities. Parametric images showed a bright band in the area spanned by endocardial motion, with reduced brightness and thickness in areas of hypokinesis. The agreement between the radiologists' grades and the gold standard significantly improved by adding parametric images (from 77% to 81%), which also resulted in reduced interobserver variability (from 52% to 33%). CONCLUSIONS: Still-frame parametric images aid in the assessment of regional wall motion by non-cardiologists who are required to interpret cardiac images.

Female↗

Dynamic three-dimensional color flow Doppler: an improved technique for the assessment of mitral regurgitation.

BACKGROUND: Prior studies have reconstructed mitral regurgitant flow in three dimensions displaying gray scale renditions of the jets, which were difficult to differentiate from surrounding cardiac structures. Recently, a color-coded display of three-dimensional (3D) regurgitant flow has been developed. However, this display was unable to integrate cardiac anatomy, thereby losing spatial information, which made it difficult to determine the jet origin and its spatial trajectory. To overcome this limitation, an improved method of 3D color reconstruction of regurgitant jets obtained from color flow Doppler using a transesophageal approach was developed to allow the combined display of both color flow and gray scale information. OBJECTIVES: To demonstrate the feasibility of 3D reconstruction of regurgitant mitral flow jets using an improved method of color encoding digital data acquired by transesophageal echocardiography (TEE). METHODS: We studied 46 patients undergoing a clinically indicated TEE study. All subjects had mitral regurgitation detected on a previous transthoracic study. Atrial fibrillation or poor image quality were not used as exclusion criteria. The 3D study was performed using a commercial ultrasound imaging system with a TEE probe (Sonos 5500, Agilent Technologies). A rotational mode of acquisition was used to collect two-dimensional (2D) color flow images at 3-degree intervals over 180 degrees. Images were processed off line using the Echo-View Software (TomTec Imaging Systems). Volume-rendered 3D color flow jets were displayed along with gray scale information of the adjacent cardiac structures. RESULTS: Mitral regurgitant flow, displayed in left atrial and two longitudinal orientations, was successfully reconstructed in all patients. The time for acquisition, post-processing, and rendering ranged between 10 and 15 minutes. There were 28 centrally directed jets and 15 eccentric lesions. Eight patients in the study had periprosthetic mitral regurgitant flow. CONCLUSIONS: Three-dimensional imaging of mitral regurgitant jets is feasible in the majority of patients. This improved technique provides additional information to that obtained from the 2D examination. Particularly, in patients with paravalvular leaks 3D color flow Doppler provides information on the origin and the extent of the dehiscence, as well as insight into the jet direction. In addition, in patients with eccentric mitral regurgitation, this new modality overcomes the inherent limitations of 2D echo Doppler by depicting the full extent of the jet trajectory.

Echocardiography, Doppler, Color↗

Use of contrast enhancement for the assessment of left ventricular function.

Endocardial visualization is essential for accurate interpretation of regional wall thickening abnormalities, which constitute the diagnostic hallmark of coronary artery disease, and for reproducible assessment of left ventricular (LV) ejection fraction. Unfortunately, in many cardiac patients, poor image quality does not allow consistent visualization, let alone automated detection, of the endocardial boundary in all segments throughout the cardiac cycle. Continuing efforts directed towards improving endocardial visualization made by both echocardiographic imaging equipment manufacturers and researchers have recently produced new objective, quantitative approaches for the assessment of global and regional LV function. Although these developments have not been integrated into routine clinical practice, they may have a positive impact on endocardial visualization and, thus, eventually improve the ability to accurately and objectively evaluate LV performance. In this review, we discuss some of the latest developments in the use of contrast for the evaluation of LV function.

Animals↗

Assessment of global and regional left ventricular diastolic function in hypertensive heart disease using automated border detection techniques.

Acoustic quantification (AQ) and color kinesis (CK) are techniques that involve automated detection and tracking of endocardial borders. These methods are useful for the evaluation of global and regional left ventricular (LV) systolic function and more recently have been applied to evaluating LV diastolic performance. Assessment of diastolic dysfunction in hypertensive heart disease is a relevant clinical issue in which these techniques have proven useful. The diastolic portion of left atrium and LV AQ area waveforms are frequently abnormal in patients with left ventricular hypertrophy (LVH). Left ventricular AQ curves consistently demonstrate reduced rapid filling fraction (RFF) and peak rapid filling rate (PRFR), elevated atrial filling fraction (AFF), peak atrial filling rate (PAFR), and reductions in the ratio PRFR/PAFR. Acoustic quantification complements traditional Doppler echocardiographic evaluation of global diastolic function. Many patients with significant LVH and normal Doppler diastolic parameters can be identified as having diastolic dysfunction with AQ. In addition, CK has allowed the evaluation of regional diastolic performance in hypertensive patients. Regional filling curves obtained from CK have demonstrated that endocardial diastolic motion is commonly delayed and heterogeneous in patients with LVH.

Diastole↗

Accuracy of mitral valve area measurements using transthoracic rapid freehand 3-dimensional scanning: comparison with noninvasive and invasive methods.

OBJECTIVE: The feasibility and accuracy of direct transthoracic 3-dimensional (3D) mitral valve area (MVA) measurements obtained using freehand scanning was investigated in patients with mitral stenosis. METHODS: A total of 30 patients (26 women, 4 men; aged 55 +/- 13 years) underwent a 2-dimensional (2D) and Doppler study 1 hour before percutaneous balloon mitral valvuloplasty. Transthoracic freehand data were acquired using a magnetic receiver attached to a broadband transducer, gated to electrocardiography and respiration. Volumetric MVA measurements from the left ventricle and left atrium were obtained and compared with MVA measurements derived from 2D planimetry, pressure half-time, and proximal isovelocity surface area. Invasive Gorlin MVA measurements were the gold standard for comparison. RESULTS: In all, 29 patients (97%) had 3D data allowing MVA measurements. Direct 3D measurements from the left ventricle had the least bias (0.06 +/- 0.19 cm(2)) and tightest limits of agreement (-0.44 to 0.32) compared with left atrium measurements (0.17 +/- 0.25 cm(2) and -0.67 to 0.33, respectively). The proximal isovelocity surface area method (bias: 0.09 +/- 0.34 cm(2)) was the most accurate of all 2D methods followed by pressure half-time (0.17 +/- 0.36 cm(2)) and planimetry (0.21 +/- 0.29 cm(2)). CONCLUSION: Direct 3D MVA measurements from the left ventricle using transthoracic freehand scanning are more accurate than traditional 2D methods.

Adult↗

Simultaneous real-time echocardiographic imaging of myocardial perfusion and regional function using color-encoded, contrast-enhanced power modulation.

We hypothesized that color-encoded, contrast-enhanced, power modulation imaging could allow simultaneous quantification of myocardial perfusion and regional left ventricular function. We studied 12 anesthetized, closed-chest pigs at baseline, during acute ischemia, and during reperfusion, and 8 patients after acute myocardial infarction. Color kinesis was used to color encode endocardial motion during real-time contrast perfusion imaging with high-energy ultrasound pulses. Wall motion was assessed by calculating regional fractional area changes. Translation-free perfusion analysis was performed in automatically identified myocardial regions of interest. Steady-state intensity and postimpulse rate of contrast replenishment were calculated. In all animals, ischemia caused reversible changes in the images and the perfusion- and function-calculated indices. A significant decrease in pixel intensity (14%) and contrast replenishment rate (66%) in left anterior descending coronary artery segments, in agreement with fluorescent microspheres measurements, coincided with a decrease in fractional area change (34%). For patients, respective perfusion and function indices were 61%, 51%, and 58% lower in segments where perfusion defects, regional wall-motion abnormalities, or both were noted in gray scale images. Color-encoded, contrast-enhanced power modulation allows simultaneous real-time imaging and quantitative analysis of myocardial perfusion and regional left ventricular function.

Animals↗

Normal values of left ventricular systolic and diastolic function derived from signal-averaged acoustic quantification waveforms: a multicenter study.

Automated border-detection techniques such as acoustic quantification have proven accurate and useful for quantifying left ventricular (LV) function. We acquired LV acoustic quantification waveforms from the parasternal short-axis window in 140 healthy patients in the age range of 16 to 78 years. Signal-averaged waveforms were analyzed for parameters of systolic and diastolic performance. The average fractional area change was 54 +/- 12%, and there were no significant changes in LV systolic function in the age range studied. There were significant changes in diastolic parameters with aging. The percentage of contribution to total LV filling occurring during atrial filling nearly tripled during the 6 decades studied, from 13% in the youngest cohort to 36% in the eighth decade of life. This study provides normal reference values for systolic and diastolic parameters of LV function determined from signal-averaged acoustic quantification waveforms acquired from the parasternal short-axis view in adult and adolescent patients over a wide age range.

Adolescent↗

Quantification of regional myocardial perfusion using semiautomated translation-free analysis of contrast-enhanced power modulation images.

Quantitative analysis of myocardial perfusion is currently based on manual tracing and frame-by-frame realignment of regions of interest. We developed a technique for semiautomated identification of myocardial regions from power modulation images as a potential tool for quantification of myocardial contrast enhancement. This approach was tested in 13 anesthetized pigs during continuous intravenous infusion of contrast at baseline, left anterior descending coronary artery occlusion, and reperfusion. Regional pixel intensity was calculated for each consecutive end-systolic frame after a high-energy ultrasound impulse, and fitted with an exponential function. Perfusion defects caused by occlusion of left anterior descending coronary artery were confirmed by a significant decrease in both postimpulse steady-state intensity and the initial rate of contrast replenishment (P <.05), which were reversed with reperfusion. Automated measurements of myocardial intensity correlated highly with conventional manual tracing (r = 0.90 to 0.97), and resulted in improved signal-to-noise ratios. This technique allows translation-free quantification of regional myocardial perfusion, without the need for manual tracing.

Algorithms↗

Current state of intraoperative echocardiography.

Intraoperative use of echocardiography is becoming more prevalent and is now considered an essential part of modern cardiac surgery. Echocardiography can be performed intraoperatively using transesophageal, epicardial or epiaortic, and substernal approaches. These techniques have a variety of applications in evaluating myocardial and valvular function, assessing aortic atheroma, and determining adequacy of various kinds of repair and reconstruction. Future applications will most likely involve more compact equipment, the implementation of epicardial and transesophageal real-time three-dimensional echocardiography, and better use of provocative methods of intraoperative testing.

Adult↗

The role of contrast enhancement in echocardiographic assessment of left ventricular function.

With or without contrast, echocardiographic evaluation of left ventricular (LV) function is qualitative, subjective, and experience dependent, because it is mostly based on visual interpretation of gray-scale 2-dimensional images or, at best, relies on tedious and time-consuming manual tracing of the endocardial boundaries. Adequate endocardial visualization is essential for accurate interpretation of regional wall thickening abnormalities, which constitute the diagnostic hallmark of coronary artery disease, and for reproducible assessment of LV ejection fraction. Studies performed in the last decade have estimated the number of patients with suboptimal endocardial delineation by fundamental imaging at 30%. These studies have highlighted the problem of variable image quality as a major limitation of transthoracic echocardiography because failure to adequately visualize a segment, either at rest or during stress, may compromise the ability of this technique to identify areas of dysfunctional myocardium. Several remedies based on different technologic and methodologic approaches have been tested over the years with variable success. In this review we discuss the most recent techniques that have had a positive impact on endocardial visualization, as well as the potential benefits of these approaches.

Contrast Media↗

Objective assessment of left ventricular wall motion from contrast-enhanced power modulation images.

There is no method to objectively evaluate left ventricular (LV) function from contrast-enhanced images. We tested the feasibility of evaluating regional LV function by using power modulation imaging. In protocol 1, 9 anesthetized closed-chest pigs were studied. Images were obtained during contrast infusion at baseline, during LAD occlusion and reperfusion. In protocol 2, images were obtained in 20 patients (14 wall-motion abnormalities; 6 controls) during contrast enhancement. Off-line, frame-by-frame, semiautomated endocardial border detection was followed by color encoding of endocardial motion, followed by segmentation and calculation of regional fractional area changes. In all animals, coronary occlusions resulted in hypokinesis and decreased fractional area changes in LAD-related segments only, which were reversed during reperfusion. In patients, wall-motion analysis was in agreement with an expert reader of dynamic images in 92.5% segments, with interobserver variability of 12.5%. Color encoding of endocardial motion from contrast-enhanced power modulation images allows accurate quantitative assessment of regional LV function.

Aged↗

Improvement in echocardiographic evaluation of left ventricular wall motion using still-frame parametric imaging.

BACKGROUND: Conventional echocardiographic assessment of left ventricular wall motion is based on visual interpretation of dynamic images, which depends on readers' experience. We tested the feasibility of evaluating endocardial motion using still-frame parametric images. METHODS AND RESULTS: In protocol 1, integrated backscatter images were obtained in 8 anesthetized pigs at baseline, 5, and 60 seconds after left anterior descending coronary occlusion and during reperfusion. Images from 1 cardiac cycle were analyzed offline to create a parametric image of local video intensity oscillations. Ischemia-induced changes were quantified by segmenting the parametric images and calculating regional pixel-intensity profiles. In protocol 2, parametric images were obtained from contrast-enhanced echocardiograms in 30 patients (18 with wall-motion abnormalities; 12 control subjects). "Gold standard" for wall motion was determined from independent interpretations of dynamic images made by 3 experienced reviewers. Dynamic images were independently classified by 3 inexperienced and 3 intermediate-level readers. Interpretation was then repeated in combination with parametric images. Parametric images showed a bright band in the area spanned by endocardial motion, which gradually decreased in brightness and thickness in the left anterior descending territory during coronary occlusion in all animals. In patients, the agreement with the gold standard correlated with the readers' experience (68% inexperienced, 87% intermediate) and significantly improved by adding parametric images (83% and 91%, respectively). CONCLUSION: Parametric imaging provides a still-frame display of regional endocardial motion, sensitive to track ischemia-induced abnormalities. When combined with dynamic images, this technique improves the accuracy of the interpretation of wall motion, especially by less experienced echocardiographers.

Aged↗

Automated endocardial border detection and evaluation of left ventricular function from contrast-enhanced images using modified acoustic quantification.

Automated border detection (ABD) techniques have been used for the quantitative assessment of left ventricular (LV) performance but require adequate visualization of the endocardial border to accurately track the blood-tissue interface. We sought to evaluate whether ABD could be used in conjunction with an infusion of echocardiographic contrast to objectively quantify LV systolic performance. Twenty-one subjects had LV volume and ejection fraction (EF) assessed by hand-tracing and prototype ABD software during contrast infusion. The mean hand-traced EF was 45% +/- 16%. Automatic tracking of contrast-enhanced endocardial borders with prototype ABD software was possible in all subjects. This allowed generation of signal averaged LV volume waveforms, from which quantitative LV ejection fraction was obtained. There were no significant differences in LV volumes or EF between contrast-enhanced acoustic quantification and manually traced borders. This technique has the potential of providing objective quantitation of LV volume and function in patients with technically limited echocardiograms.

Acoustics↗