PubMed Health⌕ Search

PubMed · 15511455

Ventricular resynchronization by multisite pacing improves myocardial performance in the postoperative single-ventricle patient.

Abstract

BACKGROUND: Ventricular resynchronization with multisite pacing in heart failure patients results in acute improvement of myocardial performance, but the mechanism is unknown. Our goals were to determine whether multisite pacing results in acute improvement of myocardial performance in postoperative single-ventricle patients, and to elucidate the mechanism by assessing the synchronization of regional ventricular contraction during multisite pacing using real-time three-dimensional echocardiographic imaging. METHODS: Multisite pacing studies were performed in 26 single-ventricle patients (mean age, 28 months; range, 7 days to 11 years) undergoing some form of single-ventricle palliation (stage I Norwood, 4; aortopulmonary shunt, 1; cavopulmonary shunt, 9; Fontan, 8; Fontan revision, 3; valve replacement, 1). Electrocardiogram, blood pressure, mixed-venous oxygen saturation, and three-dimensional echocardiograms (n = 10) were recorded at baseline and during multisite pacing. Data were analyzed to obtain regional volume-time curves for 16 three-dimensional segments of the systemic ventricle. An index of asynchrony was calculated at baseline and during pacing as the standard deviation of all segmental volume-time curves from onset to end of ejection. RESULTS: With multisite pacing performed at a median postoperative day 2 (range, 0 to 9), QRS duration decreased in 24 of 26 patients (93.9 +/- 17.5 versus 71.7 +/- 10.8 ms; p < 0.001); systolic blood pressure increased in 25 of 26 patients (86.3 +/- 20.0 versus 93.8 +/- 20.2 mm Hg; p < 0.001); cardiac index increased in 21 of 22 patients (3.2 +/- 0.8 versus 3.7 +/- 1.0 L x min(-1) x m(-2); p < 0.001); and the index of asynchrony improved in 8 of 10 patients (10.3 +/- 4.8 versus 6.0 +/- 1.4; p < 0.04). CONCLUSIONS: Multisite pacing improves cardiac performance after single-ventricle palliation. Real-time three-dimensional echocardiography demonstrated that multisite pacing improved the synchrony of ventricular contraction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Emile A Bacha, Frank J Zimmerman, Victor Mor-Avi, Lynn Weinert, Joanne P Starr, Lissa Sugeng, Roberto M Lang. 2004. Ventricular resynchronization by multisite pacing improves myocardial performance in the postoperative single-ventricle patient.. https://doi.org/10.1016/j.athoracsur.2004.04.065

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Medium-term follow-up and modes of failure following epicardial pacemaker implantation in young children.

AIMS: Young children suffering from congenital or post-operative AV-block require life-long pacemaker stimulation. Due to the anatomical prerequisites initially epicardial electrodes are implanted and the generator is placed in the upper abdominal wall. The following study investigated modes of failure leading to reoperation in this group of technically challenging patients. METHODS AND RESULTS: Between October 2000 and May 2005, a total of 21 infants (age 3 days to 5 years) underwent pacemaker implantation using a subxyphoidal incision for newborns (and a partial lower or complete median sternotomy for older children). Nine patients had previous cardiac surgery for complex congenital defects. The remaining 12 young children suffered from congenital AV-Block (CAVB). Twenty-one bipolar epicardial electrodes (Medtronic Capsure epi) were fixed to the right ventricle, 15 had additional implantation of a bipolar atrial lead. The pacemaker generator (Medtronic Kappa 701) was implanted into the right upper abdominal wall. Indications for revision were recorded. No mortality was observed; pacing and sensing parameters remained stable up to a 5-year follow-up. A total of four reoperations occurred. Three of the four revisions were caused by ventricular electrode fracture. At revision, two electrodes were broken at the crossing between the pericardial cavity and the abdominal wall, one bipolar lead at the Y-division into the two tip electrodes. One reoperation was due to a pacemaker recall. All revisions were performed without complications. CONCLUSION: In our institute epicardial pacing in young children was associated with a satisfactory clinical outcome, but also a significant number of failures leading to reoperation, mainly due to electrode fracture caused by the muscular activity of this patient group. Reoperations were performed at a low risk.

Cardiac Pacing, Artificial↗

Spectral pulsed-wave tissue Doppler imaging lateral-to-septal delay fails to predict clinical or echocardiographic outcome after cardiac resynchronization therapy.

AIMS: The current study sought to assess if pre-implantation lateral-to-septal delay (LSD) > or =60 ms assessed by spectral pulsed-wave myocardial tissue Doppler imaging (PW-TDI) could predict successful long-term outcome after cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Sixty patients (72% males, mean age 59 +/- 10 years) who were referred for CRT according to the ACC/ESC guidelines were enrolled in the study. All patients underwent spectral PW-TDI before and 1 year after CRT. Two left ventricular (LV) dyssynchrony time intervals, T(O) and T(P) (time to onset and peak of LV myocardial velocity, respectively), LSD were recorded. Left ventricular dyssynchrony was defined as LSD > or =60 ms. Clinical response was defined as an improvement in >1 NYHA class plus improvement in 6-min walk distance (6MWD) > or =25%, echocardiographic response was defined as a > or =15% reduction in LV end-systolic volume (LV-ESV). One year after CRT, 50 patients (83%) were clinical responders and 47 patients (78%) were echocardiographic responders. Both T(O) and T(P) LV dyssynchrony indices failed to predict echocardiographic CRT outcome. In addition, there were no significant differences between 'synchronous' and 'dyssynchronous' patient populations at baseline or follow-up in either clinical (NYHA class and 6MWD) or echocardiographic (LV ejection fraction, LV end-diastolic, and end-systolic) variables. CONCLUSION: The great majority of patients referred for CRT benefit clinically from it. However, spectral PW-TDI failed to predict CRT outcome. When PW-TDI dyssynchrony was applied for selection of proper CRT patients, up to 80-86% of the patients with synchronous LSD that had proven clinical and echocardiographic benefit from CRT would have been denied CRT.

Cardiac Pacing, Artificial↗