PubMed Health⌕ Search

Biomedical subjects

Vincenzo Lucidi

Publications and source records attributed to Vincenzo Lucidi.

2 recordsLinked to original sources

Initial computed tomography imaging experience using a new macromolecular iodinated contrast medium in experimental breast cancer.

OBJECTIVE: The objective of this study was to evaluate computed tomography (CT) enhancement characteristics for a new iodinated macromolecular contrast medium (MMCM), PEG12000-Gen4-triiodo, for angiographic effect and for assessment of abnormal vascular permeability in cancer. MATERIALS AND METHODS: Time persistence of angiographic effect was evaluated on rat CT images acquired over 30 minutes using the iodinated polyethyleneglycol- (PEG) based macromolecule. Dynamic CT imaging after PEG12000-Gen4-triiodo-enhancement in tumor-bearing rats was used to quantitatively estimate plasma volume and microvascular transendothelial permeability for both tumor and normal soft tissue. Using identical doses of iodine, 300 mg iodine/kg, blood curves for this MMCM and iohexol were compared. RESULTS: Serial whole-body CT angiograms using PEG12000-Gen4-triiodo showed diagnostic vascular detail through 20 minutes, and the blood enhancement curve was higher and more persistent than with small-molecular iohexol. Permeability estimates were significantly (P<0.02; paired t test) higher in tumors (48.2+/-18.1 microL/min-1 100 mL) than in muscle (2.5+/-5.7 microL/min-1 100 mL). CONCLUSIONS: Use of PEG-based MMCM for experimental CT allowed for a persistent angiographic enhancement and for quantitative estimation of tumor microvascular characteristics.

Animals↗

MR angiography of the carotid arteries: parameters affecting image quality.

RATIONALE AND OBJECTIVES: This study was performed to evaluate the relationship between dose levels of contrast medium and image quality in magnetic resonance (MR) angiography of the carotid arteries with fluoroscopically monitored, manually triggered, elliptically ordered image acquisitions. MATERIALS AND METHODS: Twenty-five patients with clinical indications for angiography of the carotid arteries were examined with MR at 1.5 T by using a fluoroscopically monitored, manually triggered, elliptically ordered pulse sequence with the administration of one of three different volumes of gadolinium-based contrast medium. The signal intensities of the vessel lumen and the surrounding tissues were measured in single partitions at the origin of the common carotid artery, the carotid bifurcation, and the intracranial internal carotid arteries. The contrast-to-noise ratio in these regions of interest also was measured. Maximum intensity projection image quality was appraised for blurring, artifacts, venous enhancement, background suppression, and contrast medium distribution. RESULTS: No artifacts or venous enhancement was observed. The position of the fluoroscopic section affected the distribution of contrast medium along the vessel, as evidenced by the difference between the contrast-to-noise ratio at the origin of the common carotid artery and the ratio at the carotid bifurcation and the intracranial internal carotid arteries (P < .01). The contrast medium dose administered was strongly correlated with image quality (r = 0.90). CONCLUSION: Contrast medium dose is related to image quality in MR angiography of the carotid arteries performed with elliptical ordering, fluoroscopic monitoring, and manual triggering.

Aged↗