PubMed Health⌕ Search

Biomedical subjects

Vivienne C Greenstein

Publications and source records attributed to Vivienne C Greenstein.

17 recordsLinked to original sources

Detecting early functional damage in glaucoma suspect and ocular hypertensive patients with the multifocal VEP technique.

PURPOSE: To determine whether the multifocal visual evoked potential (mfVEP) technique can detect early functional damage in ocular hypertensive (OHT) and glaucoma suspect (GS) patients with normal standard achromatic automated perimetry (SAP) results. PATIENTS AND METHODS: Twenty-five GS patients (25 eyes), 25 patients with OHT (25 eyes), and 50 normal controls (50 eyes) were enrolled in this study. All GS, OHT and normal control eyes had normal SAP as defined by a pattern standard deviation and mean deviation within the 95% confidence interval and a glaucoma hemifield test within normal limits on the Humphrey visual field 24-2 program. Eyes with GS had optic disc changes consistent with glaucoma with or without raised intraocular pressure (IOP), and eyes with OHT showed no evidence of glaucomatous optic neuropathy and IOPs >or=22 mm Hg. Monocular mfVEPs were obtained from both eyes of each subject using a pattern-reversal dartboard array with 60 sectors. The entire display had a radius of 22.3 degrees. The mfVEPs, for each eye, were defined as abnormal when either the monocular or interocular probability plot had a cluster of 3 or more contiguous points with P<0.05 and at least 2 of these points with P<0.01. RESULTS: The mfVEP results were abnormal in 4% of the eyes from normal subjects. Abnormal mfVEPs were detected in 20% of the eyes of GS patients and 16% of the eyes of OHT patients. Significantly more mfVEP abnormalities were detected in GS patients than in normal controls. However, there was no significant difference in mfVEP results between OHT patients and normal controls. CONCLUSIONS: The mfVEP technique can detect visual field deficits in a minority of eyes with glaucomatous optic disks and normal SAP results.

Disease Progression↗

A comparison between multifocal and conventional VEP latency changes secondary to glaucomatous damage.

PURPOSE: To compare latencies of conventional visual evoked potentials (cVEPs) and multifocal VEPs (mfVEPs) in the same patients. Previous reports of prolonged cVEP latency suggest a vehicle for detecting abnormal ganglion cells and for monitoring neuroprotection. METHODS: Seventy-five glaucomatous eyes (47 patients), 75 eyes with suspected glaucoma (46 patients), and 41 control eyes (22 subjects) underwent achromatic automated perimetry and mfVEP and cVEP testing. The mfVEP stimulus was a scaled dart board with 60 sectors; each sector was a pattern-reversing checkerboard. The cVEP stimulus was a reversing checkerboard with checks of either 15 minutes or 60 minutes in width. RESULTS: Relatively few glaucomatous eyes had latencies that fell outside the range of control eyes, and there was little difference between the cVEP and mfVEP results. In the glaucoma group, 12.3% (15 minutes cVEP), 8% (60 minutes cVEP), and 17.3% (mfVEP) of the eyes and 5.3% (15 minutes cVEP), 6.7% (60 minutes cVEP), and 5.3% (mfVEP) of the suspect eyes exceeded the normal range. The glaucomatous eyes had, on average, relatively small increases in latency, compared with the control or suspect groups. Further, the latency of both the mfVEP and cVEP bore no obvious relationship to the mean deviation of the visual field. CONCLUSIONS: Contrary to previous reports, prolonged VEP delays were present in a minority of patients with glaucoma. Either a delayed VEP is not a good indicator of damaged, as opposed to dead, retinal ganglion cells, or there are relatively few patients who exhibit evidence of damaged ganglion cells.

Adolescent↗

The pattern electroretinogram in glaucoma patients with confirmed visual field deficits.

PURPOSE: To better understand the relationship between the amplitude of the pattern electroretinogram (PERG) and visual loss, measured with static automated perimetry. METHODS: Transient PERGs were recorded in 15 patients (31-77 years) and 16 normal individuals (26-65 years). An eye was considered to have glaucomatous damage only if there was an abnormal disc, an abnormal 24-2 Humphrey visual field result (pattern stand deviation, glaucoma hemifield test, and cluster) and an abnormal multifocal visual evoked potential. All the worse (more affected) eyes of the patients and six of the better eyes met these criteria. The N95 amplitude of the PERG was measured from the positive peak (P50) at approximately 50 ms to the trough at approximately 95 ms. The ratio of N95 to P50-the N95 amplitude divided by the P50 amplitude-was also measured. RESULTS: First, the PERG was within normal limits for 4 (26.7%) of the worse eyes. Overall, 6 (28.6%) of the 21 eyes that met the criteria for glaucomatous damage had normal PERGs on both PERG measures. Because the normal individuals were younger than the patients, an even larger number of normal PERGs might be expected with an age-appropriate control group. Second, the N95 amplitude was nonlinearly related to visual field sensitivity when sensitivity was plotted on a linear plot. Small field losses were associated with disproportionately large losses in PERG amplitude. Third, the PERG from both eyes of a patient were very similar, even when the visual fields suggested very different levels of damage. CONCLUSIONS: These results are consistent with the view that very early damage can affect the PERG, even before the visual field shows a loss. At the same time, it is clear that patients with clear glaucomatous damage can have normal-appearing PERGs. An explanation is proposed to account for these findings.

Adult↗

The multifocal visual evoked potential: an objective measure of visual fields?

We examined the effects of inter-modal attention and mental arithmetic on Humphrey visual field sensitivity and multifocal visual evoked potential (mfVEP) amplitude. Four normally sighted subjects (ages ranging from 24 to 58 years) participated in this study. Monocular visual field sensitivity was measured under two conditions: (1) standard testing condition and (2) while the subject performed a Paced Auditory Serial Addition Task (PASAT). Monocular mfVEPs were recorded in response to a 60-sector stimulus. The checkerboard pattern in each sector was contrast reversed according to a binary m-sequence. mfVEPs were recorded under two conditions: (1) standard testing conditions and (2) while the subject performed a PASAT. We found that, when compared to the no-task condition, all subjects had locations of significantly reduced Humphrey visual field sensitivities when performing the PASAT. In contrast, there were no significant decreases in mfVEP amplitude in any sector for any of the subjects while performing the PASAT. Our findings indicate that divided attention and ongoing mental processes did not affect the mfVEP. Therefore, the mfVEP provides an objective measure of visual field function that may be useful for some patients with unreliable automated static perimetry results.

Adult↗

A method for comparing electrophysiological, psychophysical, and structural measures of glaucomatous damage.

OBJECTIVE: To develop a method for comparing multifocal visual-evoked potential (mfVEP) responses and behaviorally determined visual fields with structural measures of the optic nerve head. METHODS: Humphrey 24-2 visual fields and mfVEPs were obtained from each eye of 20 patients with open-angle glaucoma. Monocular and interocular analyses were performed to identify locations with abnormal mfVEP responses. Optic discs were assessed with a confocal scanning laser ophthalmoscope (Heidelberg Retina Tomograph II). The image of the optic nerve head was divided into 6 sectors. The rim and disc area measurements for each sector were compared with those in a normal database using Moorfields regression analysis. The optic nerve head measurements for the 6 sectors were related to the Humphrey visual field locations and the 60 sectors of the mfVEP display. RESULTS: Of 240 sectors tested (40 eyes x 6 sectors), 18.8% on Humphrey visual field, 22.1% on mfVEP, and 10.8% on confocal scanning laser ophthalmoscopic testing were significantly different from those of control subjects. There were no significant deficits in 165 sectors. There was agreement for 86.7% of the sectors when the Humphrey visual field and mfVEP results were compared. The confocal scanning laser ophthalmoscopic results were in agreement for 84.6% of these sectors. CONCLUSIONS: The method used allows for a comparison among measures of visual function and a structural measure of the optic nerve head. In general, the results of the functional and structural measures showed agreement; however, there were clear examples of disagreements that merit further study.

Adult↗

Test-retest reliability of the multifocal electroretinogram and humphrey visual fields in patients with retinitis pigmentosa.

We examined the reliability of Humphrey visual field thresholds and multifocal electroretinogram (mfERG) amplitudes and timing in a group of patients with Retinitis Pigmentosa (RP). Eight patients with RP and seven control subjects were tested five times: at baseline (visit #0), at three weekly follow-up visits (visits #1 - #3), and at three months (visit #4). For the Humphrey thresholds, differences between dB values on repeat visits were obtained. Differences between log values on repeat visits were calculated for mfERG amplitude and implicit time. We used the standard deviations of these difference scores as a measure of reliability and the means of the difference scores as a measure of progression. We found that the majority of the patients' repeat data were more variable than that of the control subjects for both the Humphrey and mfERG. We found no single factor that predicted the magnitude, or the variance, of the SD of differences scores for the patients. We recommend that each patient's reliability be assessed individually. Ultimately, the choice of an outcome measure must be guided by its reliability, as well as its ability to assess the visual function of interest.

Adult↗

Detecting early to mild glaucomatous damage: a comparison of the multifocal VEP and automated perimetry.

PURPOSE: To gain better understanding of the relationship between abnormalities detected by the multifocal VEP (mfVEP) compared with those detected by static achromatic, automated perimetry in patients with glaucoma. METHODS: Fifty patients were studied who had open-angle glaucoma that met the following criteria: (1) a mean deviation (MD) of better than -8 dB in both eyes on the 24-2 Humphrey visual field (HVF) test (Carl Zeiss Meditec, Dublin, CA); and (2) glaucomatous damage in at least one eye, as defined by a glaucomatous optic disc and an abnormal 24-2 HVF test result (pattern standard deviation [PSD] <5% and/or glaucoma hemifield test [GHT] results outside normal limits). Monocular mfVEPs were obtained from each eye by using a pattern-reversal dartboard array, 44.5 degrees in diameter, which contained 60 sectors. Recording electrodes were placed at the inion (I) and I+4 cm, and also at two lateral locations up 1 cm and over 4 cm from I. Monocular and interocular mfVEP probability plots were derived by comparing the results with those of normal control subjects. For both the HVF and mfVEP probability plots, a hemifield was classified as abnormal if three or more contiguous points were significant at less than 5%, with at least one at less than 1%. RESULTS: Of the 200 hemifields tested (50 patients x two eyes x two hemifields), 75 showed significant clusters on the HVF, and 74 (monocular probability plot) and 93 (monocular or interocular plot) showed significant clusters on the mfVEP. Overall, the HVF and mfVEP results agreed on 74% of the hemifields, and 90 hemifields were normal and 58 were abnormal on both the mfVEP (interocular and/or monocular abnormal) and HVF cluster tests. Of the 52 disagreements, 35 hemifields had a significant cluster on the mfVEP, but not on the HVF, whereas the reverse was true of 17 hemifields. A case-by-case analysis indicated that misses and false-positive results occurred on both the HVF and mfVEP tests. CONCLUSIONS: As predicted from a theoretical analysis, under these conditions (i.e., the signal-to-noise level) the HVF and monocular mfVEP tests showed a comparable number of defects, and, with the addition of the interocular test, the mfVEP showed more abnormalities than the HVF. However, although there were abnormalities detected by the mfVEP that were missed by the HVF, the reverse was true as well.

Adult↗

Rod and cone photoreceptor function in patients with cone dystrophy.

PURPOSE: To determine the extent of rod and cone photoreceptor dysfunction in patients with cone dystrophy using psychophysical and electrophysiological tests. METHODS: Ten patients with cone dystrophy participated. Rod and cone system psychophysical thresholds were measured as a function of retinal eccentricity. Bright-flash full-field electroretinograms were obtained under dark-adapted (rod-mediated) and light-adapted (cone-mediated) conditions. The a-wave data were fitted with a model based on photopigment transduction to obtain values for log Rmax (maximum response) and log S (sensitivity). b-Wave parameters were also examined by fitting a nonlinear, saturating function (the Naka-Rushton equation) to the rod-mediated responses. Oscillatory potentials were measured to the cone-mediated high-intensity flashes. RESULTS: On average, the rod-mediated psychophysical thresholds were elevated by 0.5 log unit. These threshold elevations did not differ significantly with retinal eccentricity. In contrast, cone-mediated psychophysical thresholds were elevated up to 3.0 log units. Threshold elevation was greatest in the central retinal locations. For rod-mediated conditions, the a-wave Rmax parameter was significantly reduced in three patients; the a-wave log S parameter was within normal limits. The rod-mediated b-wave Rmax parameter was reduced in six patients; log k was abnormal in one patient. For cone-mediated conditions, the a-wave Rmax parameter was reduced in six patients and the a-wave log S parameter was reduced in two patients. The cone system oscillatory potentials were abnormal in nine patients. CONCLUSIONS: Patients with cone dystrophy show different patterns of psychophysical rod versus cone system sensitivity losses with retinal eccentricity. The full-field electrophysiological data indicate that most of the patients had abnormal cone photoreceptor function. Some patients also showed rod photoreceptor abnormalities. The rod system changes were smaller than the cone system changes.

Adult↗

Multifocal visual evoked potential responses in glaucoma patients with unilateral hemifield defects.

PURPOSE: To determine whether the multifocal visual evoked potential (mfVEP) technique can detect damage to the visual system in the unaffected hemifields of patients with glaucoma and unilateral hemifield defects. DESIGN: Experimental study. METHODS: Monocular mfVEPs and achromatic automated perimetry (AAP) were obtained in both eyes of 16 patients with open-angle glaucoma and unilateral hemifield defects. The mfVEPs were obtained using a pattern-reversal dartboard array with 60 sectors; the entire display was 44.5 degrees in diameter. For each pair of mfVEP responses an interocular ratio of root-mean-square amplitude was calculated. These values were compared with the mean values obtained from 30 control subjects. Probability plots for MfVEP were derived. A cluster analysis was used to determine whether an mfVEP hemifield was normal or abnormal. RESULTS: Three of 60 (5.0%) mfVEP hemifields from control subjects had significant mfVEP deficits based upon a cluster of abnormal points. Significant mfVEP deficits were detected in the affected AAP hemifield in 15 of 16 (93.8%) glaucoma patients and in 6 of 16 patients in hemifields with apparently normal AAP. The percentage of hemifields with abnormal mfVEPs, but normal AAP, was significantly higher for the glaucoma patients than for the controls (37.5% vs 5.0%, P <.001, chi square).In glaucomatous eyes with achromatic visual fields defects limited to one hemifield, the mfVEP technique can detect evidence of glaucomatous damage in the unaffected hemifield.

Adult↗

Multifocal VEP and ganglion cell damage: applications and limitations for the study of glaucoma.

With the multifocal technique, visual evoked potentials (VEPs) can be recorded simultaneously from many regions of the visual field in a matter of minutes. Recently, the multifocal visual evoked potential technique (mfVEP) has generated considerable interest, especially among those seeking objective measures of glaucomatous damage. It is well accepted that significant ganglion cell damage can occur before functional deficits are detected with static automated achromatic perimetry, the "gold standard" for detecting and monitoring glaucomatous damage. In this article, we ask the following questions: What are the potential applications of the mfVEP technique? What are its limitations? To what extent will it replace or augment static automated achromatic perimetry? To answer these questions requires an understanding of the mfVEP technique, as well as techniques needed to relate its results to those of automated perimetry. describes how the mfVEP is elicited, recorded, derived and displayed. If both eyes of an individual are normal, then mfVEPs recorded for monocular stimulation of each eye are essentially identical. However, the amplitude and waveform of the mfVEP responses vary across individuals, as well as across the visual field within an individual. These variations in the normal mfVEPs are described in Section 3. In, these variations are related to cortical anatomy, and to the cortical sources contributing to the mfVEP. The mfVEP is predominantly generated in V1. Although there are undoubtedly extrastriate contributions, these contributions are probably smaller for the mfVEP than for the conventional VEP. The mfVEP is not a small version of the conventional VEP. To detect ganglion cell damage with the mfVEP requires methods for analyzing the responses and for displaying the results. In, a method for detecting ganglion cell damage is described. This method compares the monocular responses from the two eyes of an individual and produces a map of the defects. This map is in the form of a probability plot similar to the one used to display visual field defects measured with automated perimetry. Procedures are described for directly comparing these mfVEP probability plots to the probability plots for Humphrey visual fields (HVFs). The interocular mfVEP test described in will not be sensitive to bilateral damage. describes a test based upon monocular mfVEPs. The statistical basis of the monocular mfVEP test is relatively complex (see ). In any case, under many conditions the interocular test will be more sensitive and this is discussed in. summarizes a number of clinical applications of the mfVEP and concludes that the mfVEP has a place in the clinical management of glaucoma. To understand the limitations of the mfVEP, a signal-to-noise ratio (SNR) approach is described in. Using the techniques described in, the relationship between the amplitude of the mfVEP and the sensitivity loss of the HVF is discussed in. The evidence supports a simple model in which the amplitude of the signal portion, but not the noise portion, of the mfVEP response is proportional to HVF loss where HVF loss is expressed in linear, not dB, units. It is hypothesized that both the signal in the mfVEP, and the sensitivity of the HVF, are linearly related to ganglion cell loss. A theoretical approach, developed in, allows a direct comparison of the efficacy of the mfVEP and HVF in detecting glaucomatous damage. In short, when the mfVEP has a large SNR it will often be superior to the HVF in detecting damage. On the other hand, when the mfVEP has a small SNR, the HVF will probably be superior. summarizes the relative advantages of the HVF and the mfVEP. In summary, the mfVEP does have a place in the clinical management of glaucoma, although it is not likely to replace static automated achromatic perimetry in the near future. However, this is an evolving technology and the future will undoubtedly see major improvements in the mfVEP technique.

Diagnostic Techniques, Ophthalmological↗

Repeat reliability of the multifocal visual evoked potential in normal and glaucomatous eyes.

PURPOSE: To investigate the repeat reliability of the multifocal visual evoked potential (mfVEP). PATIENTS AND METHODS: Fifteen subjects with no known abnormalities of the visual system and 10 patients with glaucoma participated in the study. Monocular mfVEPs were recorded on two separate days, using a 60-sector, pattern-reversal dart board array. Within a single session, two 7-minute. recordings were obtained for each eye. The amplitude of each mfVEP response was obtained using a root mean square measure (RMS). An mfVEP ratio [10*log (RMS day 1 / RMS day 2)] provided a measure of the reproducibility of an individual response. The same calculations were performed for Run 1 compared with Run 2 within a day and Run 1 (Run 2) compared with Run 1 (Run 2) across days. RESULTS: For all 1800 mfVEP responses (60 sectors x 15 subjects x 2 eyes), the correlation between the amplitude on day 2 and the amplitude on day 1 was good (r = 0.85). The mean standard deviation (SD) of the 60 mfVEP ratios for the individual subjects was 1.63 dB for the 14-minute records (the combination of the two 7-minute recordings). On average for the 7-minute records, the mean SD across days was 1.77 dB while the mean SD within a day was 1.53 dB. The correlation within a day (r = 0.87) also was slightly larger than across days (r = 0.80). The mean SD decreased as the RMS amplitude increased. The patients' mean SD was 1.75 dB with r equal to 0.82. CONCLUSIONS: The repeat reliability of the mfVEP was good (approximately 1.6dB); in fact, it was better than that typically obtained with static automated perimetry (approximately 2.7dB). Repeat testing on separate days added surprisingly little to the variability seen with repeat testing within the same session.

Adolescent↗

The effect of variably tinted spectacle lenses on visual performance in cataract subjects.

PURPOSE: A body of clinical and laboratory evidence suggests that tinted spectacle lenses may have an effect on visual performance. The aim of this study was to quantify the effects of spectacle lens tint on the visual performance of 25 subjects with cataracts. METHODS: Cataracts were scored based on best-corrected acuity and by comparison with the Lens Opacity Classification System (LOCS III) plates. Visual performance was assessed by measuring contrast sensitivity with and without glare (Morphonome software version 4.0). The effect of gray, brown, yellow, green and purple tinting was evaluated. RESULTS: All subjects demonstrated an increase in contrast thresholds under glare conditions regardless of lens tint. However, brown and yellow lens tints resulted in the least amount of contrast threshold increase. Gray lens tint resulted in the largest contrast threshold increase. CONCLUSIONS: Individuals with lenticular changes may benefit from brown or yellow spectacle lenses under glare conditions.

Aged↗

Visual field defects and multifocal visual evoked potentials: evidence of a linear relationship.

OBJECTIVE: To determine the relationship between spatially localized multifocal visual evoked potentials (mfVEPs) and Humphrey visual fields (HVFs) in patients with unilateral field defects. METHODS: Humphrey visual fields and mfVEPs were obtained from 20 patients with unilateral field losses due to either ischemic optic neuropathy or glaucoma. Monocular mfVEPs were obtained for each eye. The amplitude of the mfVEP responses was calculated using root-mean-square and signal-noise ratio measures. Estimates of the HVF loss in the same regions of the field used for the mfVEP were obtained by interpolating the 24-2 HVF data. RESULTS: Monocular mfVEP amplitude decreased with HVF loss, although small mfVEP signals were not uniquely associated with poor fields. On average, the monocular mfVEP was indistinguishable from noise for field losses between -5 and -10 dB, and good monocular mfVEP amplitudes were never associated with extensive visual field loss. The interocular ratio of the mfVEP amplitudes correlated well with the difference between the HVF values of the 2 eyes, and this correlation improved with increased signal-noise ratio. CONCLUSIONS: The monocular and interocular results were consistent with a linear relationship between the amplitude of the signal portion of the mfVEP response and linear HVF loss. One way to produce this relationship would be if both the signal in the mfVEP and linear HVF loss were linearly related to the percentage of local ganglion cells lost. The clinical limitations of the mfVEP technique can be understood by taking the signal-noise ratio, and the linear model proposed herein, into consideration.

Adult↗

A method for comparing psychophysical and multifocal electroretinographic increment thresholds.

The multifocal electroretinogram (mfERG) has been commonly used as a method for obtaining objective visual fields. Although qualitative comparisons have been good, quantitative comparisons between the results from mfERG and the results from Humphrey Visual Field Analyser (HVFA) have found variable degrees of agreement depending upon the mfERG response parameter examined and/or the disease studied. Lack of agreement may be due to differences in methodology, differences in the sites of response generation, and/or differences derived from comparing suprathreshold versus threshold responses. In addition, the two procedures are performed at different levels of adaptation. We developed an approach for matching stimulus parameters and compared mfERG and psychophysical thresholds to assess the effects of technique and level of adaptation on the two responses. Psychophysical and mfERG thresholds were obtained as a function of the adaptation level (1.5-4.0 log td) and retinal location. The derived increment threshold-versus-intensity functions for both measures were fitted using the equation logT=logT(0)+log((A+A(0))/A(0))(n). We found that the values of A(0) for the mfERG data were one log unit higher than those for the psychophysical data. In addition, the value of the slope (n) for the mfERG data was shallower (0.8) than that of the psychophysical data (1.0). Predictions were made about comparisons of HVFA threshold and mfERG amplitude data in patients with retinal disease based upon a two-site model of adaptation. The data for some groups of patients could be best-fitted with a model of a disease acting at a site distal to all gain changes, whereas data from other patients were best fitted with a model of a disease acting at a site proximal to all retinal gain. The relationship between the Humphrey visual field threshold losses and mfERG amplitude reductions depends upon the site and mechanism of a particular disease process and the model of retinal gain assumed. In no case is a one-to-one relationship between the losses in the two measures predicted.

Adaptation, Ocular↗

The spatial distribution of selective attention assessed using the multifocal visual evoked potential.

To determine the manner in which attention is distributed among numerous locations in the visual space, we used a multifocal recording technique that allowed simultaneous recordings of evoked cortical activity from 12 visual field areas out to 23.6 degrees. We found that multifocal visual evoked potential (mfVEP) amplitude was larger when a region of visual space was attended than when it was not attended. The magnitude of this effect was inversely related to visual field eccentricity and there was no attention-related modulation of VEP amplitude for the most eccentric region. In addition, we found that mfVEP amplitudes in the regions contiguous to the attended region could also be larger, depending upon their spatial relationship to the attended region. Specifically, amplitudes in more central regions on the 'meridian of attention' were larger when the subject attended anywhere along that meridian.

Attention↗

Effect of variable tinted spectacle lenses on visual performance in control subjects.

PURPOSE: To evaluate quantitatively the effects of tinted spectacle lenses on visual performance in individuals without visual pathology. METHODS: Twenty-five subjects were assessed by measuring contrast sensitivity with and without glare. Gray, brown, yellow, green, purple, and blue lens tints were evaluated. Measurements were repeated with each lens tint and with a clear lens, and the order was counterbalanced within and between subjects. Glare was induced with a modified brightness acuity tester. RESULTS: All subjects demonstrated an increase in contrast thresholds under glare conditions for all lens tints. However, purple and blue lens tints resulted in the least amount of contrast threshold increase; the yellow lens tint resulted in the largest contrast threshold increase. CONCLUSIONS: Purple and blue lens tints may improve contrast sensitivity in control subjects under glare conditions.

Adult↗

Local cone and rod system function in progressive cone dystrophy.

PURPOSE: To compare the patterns of local cone and rod system impairment in patients with progressive cone dystrophy (CD) using psychophysical and electrophysiological techniques. METHODS: Local cone system function was assessed by measuring cone system thresholds (visual fields) and cone-mediated multifocal electroretinograms (mfERGs). Rod system function was assessed by measuring rod system thresholds (visual fields) and rod-mediated mfERGs. The results in a group of eight patients with CD were compared with those in an age-similar control group. RESULTS: All the patients had abnormal cone system visual field thresholds and cone-mediated mfERGs. Cone system psychophysical thresholds were elevated for targets presented within the central 10 degrees, but were within normal limits for targets at peripheral locations. Cone-mediated mfERG measures of amplitude scale and time scale were abnormal for most of the hexagons tested. Most of the rod-mediated psychophysical thresholds and mfERGs were within normal limits. Rod system losses tended to be patchy and scattered throughout the area tested. CONCLUSIONS: There was poor correspondence among local measures of cone and rod system losses in these patients with CD. The results suggest that the spatial pattern of cone system losses in this disease differs from the spatial pattern of rod system losses.

Adolescent↗