PubMed Health⌕ Search

PubMed · 11809478

A method for comparing psychophysical and multifocal electroretinographic increment thresholds.

Abstract

The multifocal electroretinogram (mfERG) has been commonly used as a method for obtaining objective visual fields. Although qualitative comparisons have been good, quantitative comparisons between the results from mfERG and the results from Humphrey Visual Field Analyser (HVFA) have found variable degrees of agreement depending upon the mfERG response parameter examined and/or the disease studied. Lack of agreement may be due to differences in methodology, differences in the sites of response generation, and/or differences derived from comparing suprathreshold versus threshold responses. In addition, the two procedures are performed at different levels of adaptation. We developed an approach for matching stimulus parameters and compared mfERG and psychophysical thresholds to assess the effects of technique and level of adaptation on the two responses. Psychophysical and mfERG thresholds were obtained as a function of the adaptation level (1.5-4.0 log td) and retinal location. The derived increment threshold-versus-intensity functions for both measures were fitted using the equation logT=logT(0)+log((A+A(0))/A(0))(n). We found that the values of A(0) for the mfERG data were one log unit higher than those for the psychophysical data. In addition, the value of the slope (n) for the mfERG data was shallower (0.8) than that of the psychophysical data (1.0). Predictions were made about comparisons of HVFA threshold and mfERG amplitude data in patients with retinal disease based upon a two-site model of adaptation. The data for some groups of patients could be best-fitted with a model of a disease acting at a site distal to all gain changes, whereas data from other patients were best fitted with a model of a disease acting at a site proximal to all retinal gain. The relationship between the Humphrey visual field threshold losses and mfERG amplitude reductions depends upon the site and mechanism of a particular disease process and the model of retinal gain assumed. In no case is a one-to-one relationship between the losses in the two measures predicted.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

William Seiple, Vivienne C Greenstein, Karen Holopigian, Ronald E Carr, Donald C Hood. 2002. A method for comparing psychophysical and multifocal electroretinographic increment thresholds.. https://doi.org/10.1016/s0042-6989(01)00276-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Phototransduction in mouse rods and cones.

Phototransduction is the process by which light triggers an electrical signal in a photoreceptor cell. Image-forming vision in vertebrates is mediated by two types of photoreceptors: the rods and the cones. In this review, we provide a summary of the success in which the mouse has served as a vertebrate model for studying rod phototransduction, with respect to both the activation and termination steps. Cones are still not as well-understood as rods partly because it is difficult to work with mouse cones due to their scarcity and fragility. The situation may change, however.

Adaptation, Ocular↗

Oculomotor plasticity: are mechanisms of adaptation for reactive and voluntary saccades separate?

Saccadic eye movements are permanently controlled and their accuracy maintained by adaptive mechanisms that compensate for physiological or pathological perturbations. In contrast to the adaptation of reactive saccades (RS) which are automatically triggered by the sudden appearance of a single target, little is known about the adaptation of voluntary saccades which allow us to intentionally scan our environment in nearly all our daily activities. In this study, we addressed this issue in human subjects by determining the properties of adaptation of scanning voluntary saccades (SVS) and comparing these features to those of RS. We also tested the reciprocal transfers of adaptation between the two saccade types. Our results revealed that SVS and RS adaptations disclosed similar adaptation fields, time course and recovery levels, with only a slightly lower after-effect for SVS. Moreover, RS and SVS main sequences both remained unaffected after adaptation. Finally and quite unexpectedly, the pattern of adaptation transfers was asymmetrical, with a much stronger transfer from SVS to RS (79%) than in the reverse direction (22%). These data demonstrate that adaptations of RS and SVS share several behavioural properties but at the same time rely on partially distinct processes. Based on these findings, it is proposed that adaptations of RS and SVS may involve a neural network including both a common site and two separate sites specifically recruited for each saccade type.

Adaptation, Ocular↗

Remote facilitation in the Fourier domain.

To explore spatial interactions between visual mechanisms in the Fourier domain we measured detection thresholds for vertical and horizontal sine-wave gratings (4.4 deg diameter) over a range of spatial frequencies (0.5-23 c/deg) in the presence of grating and plaid masks with component contrasts of 8%, orientations of +/-45 degrees and a spatial frequency of 1c/deg. The mask suppressed the target grating over a range of +/-1 octave, and the plaid produced more suppression than the grating, consistent with summation of mask components in a broadly tuned contrast gain pool. At greater differences in spatial frequency ( approximately 3 octaves), the plaid and grating masks both produced about 3 dB of facilitation (they reduced detection thresholds by a factor of about square root 2). At yet further distances ( approximately 4 octaves) the masks had no effect. The facilitation cannot be attributed to a reduction of uncertainty by the mask because (a) it occurs for mask components that have very different spatial frequencies and orientations from the test and (b) the large stimulus size and central fixation point mean there was no spatial uncertainty that could be reduced. We suggest the results are due to long-range sensory interactions (in the Fourier domain) between mask and test-channels. The effects could be due to either direct facilitation or disinhibition.

Adaptation, Ocular↗