PubMed Health⌕ Search

Biomedical subjects

W M Reichert

Publications and source records attributed to W M Reichert.

35 records · Page 2Linked to original sources

Planar integrated optical methods for examining thin films and their surface adlayers.

Thin film integrated optical waveguides (IOWs) have gained acceptance as a method for characterizing ultrathin dielectrical films and adlayers bound to the film surface. Here, we present the expressions that govern IOW methods as well as describe the common experimental configurations used in attenuated total reflection, fluorescence and Raman applications. The applications of these techniques to the study of adsorbed or surface-bound proteins to polymer and glass waveguides are reviewed.

Adsorption↗

Improving endothelial cell adhesion to vascular graft surfaces: clinical need and strategies.

Synthetic vascular grafts do not spontaneously endothelialize in humans and require some form of anticoagulation to maintain patency. Preseeding synthetic graft materials such as expanded polytetrafluoroethylene (ePTFE) and polyethylene terephthalate (PET) with endothelial cells (EC) has been examined in various in vitro and in vivo models. Although various studies provide encouraging results, clinical trials for EC seeding on synthetic grafts have not been equally successful. This paper provides a brief review of the various reports on EC seeding in animal and clinical studies. We discuss the inefficiencies associated with the EC seeding process and examine plasma protein treatment of the graft surfaces as a viable option for improving EC attachment, retention and spreading. As an alternative to existing therapies we present data on a heterogeneous ligand treatment of fibronectin (Fn) and avidin-biotin for enhanced human umbilical vein endothelial cell (HUVEC) adhesion to ePTFE graft surfaces. Control consisted of HUVECs seeded on Fn treated ePTFE graft surfaces. Functionality of HUVECs was assessed by measuring prostacyclin production of cells on both homogeneous and heterogeneous ligand treated surfaces. Laminar flow studies with a variable width flow chamber and scanning electron microscopy were used to measure initial cell retention and observe initial cell spreading on ePTFE surfaces, respectively. HUVEC retention on heterogeneous ligand treated graft surface was significantly (p < 0.001) higher compared to homogeneous ligand treated surfaces for shear stress in the range of 10-30 dyn cm(-2). HUVEC showed more cellular spreading on the heterogeneous ligand treated surface after seeding for 1-2 h. In vivo experimentation was performed in immune deficient (nude) rats by replacing a section of both the femoral arteries with 8 mnm long, 1 mm internal diameter denucleated ePTFE grafts treated with homogeneous and heterogeneous ligands respectively. Both grafts were seeded with similar cell density for 15 min prior to implantation. EC attachment and retention was measured by staining EC with hematoxylin and counting the cells before and after flow using light microscopy. The results indicate that a heterogeneous ligand treatment of graft surfaces using avidin-biotin and Fn-integrin attachment mechanisms increase cell seeding efficiency, initial cell retention and cellular spreading.

Adsorption↗

Engineering the tissue which encapsulates subcutaneous implants. I. Diffusion properties.

This report uses normal rat subcutis as a reference point to provide a quantitative analysis of small analyte transport through the tissue which encapsulates implants. Polyvinyl alcohol (PVA) with 60- and 350-micron mean pore size (PVA-60, PVA-350), nonporous PVA (PVA-skin), and stainless-steel cage (SS) specimens were implanted in the subcutis of Sprague-Dawley rats for 4 weeks to elicit a range of capsular wound-healing tissues. Histologic examination showed that the capsular tissue which formed around PVA-skin and SS specimens was densely fibrous and avascular. That forming around PVA-60 and PVA-350 was less densely fibrous and more vascular. The fibrous content of capsular tissue and subcutis was determined from eosin-stained histologic sections. Dual-chamber diffusion measurements of sodium fluorescein (Mw 376 g/mol) through capsular tissue and normal rat subcutis were used to quantitatively compare the effective diffusion coefficients of small analytes on the order of glucose. The two most fibrous capsular tissues exhibited diffusion coefficients that were statistically (p < 0.05) less than that determined for rat subcutis by 50 and 25% for PVA-skin and SS, respectively. The diffusion coefficients of the less dense capsular tissue which formed around the porous implants were not statistically different from subcutis. The experimentally measured diffusion coefficients of the two most fibrous capsular tissues were closely predicted by a simple two-component diffusion model consisting of an aqueous interstitium with an array of impenetrable bodies equal in volume fraction to the fibrous content of the tissue. This model overestimates the diffusion coefficients measured for the least fibrous tissues. Using the diffusion coefficient measured for the PVA-skin capsular tissue, a finite difference model predicts that a 200-microns-thick capsular layer would increase from 5 to 20 min the time required for subcutaneously implanted sensor to detect 95% of the blood analyte concentration. This study suggests that the fibrous capsule forming around a subcutaneously implanted smooth-surface sensor imposes a significant diffusion barrier to small analytes such as glucose, thus increasing the lag time of the sensor by as much as threefold. A corollary observation is that a sensor with a porous surface which allows tissue ingrowth may be more responsive to blood analyte fluctuations as a result of its a more vascular and less fibrous encapsulation tissue.

Animals↗

Effect of fibronectin amount and conformation on the strength of endothelial cell adhesion to HEMA/EMA copolymers.

The effect of substrate surface hydrophobicity on fibronectin (Fn) adsorption and endothelial cell adhesion strength was studied. Bovine aortic endothelial cells (BAEC) were plated for 2 h with and without preadsorbed Fn on slides coated with homopolymers and copolymers of hydrophilic polyhydroxyethylmethacrylate (polyHEMA) and hydrophobic polyethylmethacrylate (polyEMA). The polarity of the substrate was determined by Wilhelmy plate contact angle. The amount of adsorbed Fn was determined using 125I-labeled Fn. Attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy was used to detect gross conformational changes of adsorbed Fn on polyHEMA or polyEMA. BAEC were cultured in serum-free medium for 2 h and subjected to a brief exposure of laminar flow in a variable-height flow chamber that provided a range of shear stresses of 15-185 dynes/cm2. The critical shear stress to detach 50% of the cells increased with increasing EMA content to a maximum at 20% HEMA/80% EMA copolymer irrespective of the presence of preadsorbed Fn. However, the critical force increased even though there were similar amounts of Fn adsorbed on all substrates. ATR-FTIR spectroscopy showed only minor changes in beta-sheet structure of Fn adsorbed to polyHEMA and polyEMA. These results show that the force to detach cells did not increase solely with increasing amounts of adsorbed Fn; rather, these results indicate a more complex interplay involving both the amount and conformation of adsorbed Fn.

Animals↗

Femtomolar sensitivity using a channel-etched thin film waveguide fluoroimmunosensor.

A dual channel, evanescent fluoroimmunoassay format is used to detect femtomolar analyte concentrations (i.e. less than 1 part per trillion [w/w]) on an etched channel siliconoxynitride thin film integrated optical waveguide. Two assays are used to demonstrate the dose-response behaviour of the sensor: (1) a direct assay of a fluorescently-labeled protein ligand binding to an immobilized protein receptor, and (2) an indirect sandwich assay of a non-fluorescent protein ligand binding to an immobilized protein receptor, as detected by the binding of a fluorescently-labeled secondary receptor protein. A red-emitting cyanine dye (Cy-5), which minimized background fluorescence and scatter losses of the waveguide, was used in both assays. To our knowledge, this is the first report of femtomolar sensitivity in an immunosensing instrument.

Biosensing Techniques↗

Analysis of protein binding to receptor-doped lipid monolayers by Monte Carlo simulation.

This paper presents a Monte Carlo simulation (MCS) method for estimating the parameters that characterize ligand-receptor binding directly from experimentally derived binding isotherms. Binding parameters are estimated by incorporating an MCS algorithm for ligand binding to a two-dimensional receptor array into a nonlinear regression program. The MCS method was tested by analyzing experimental isotherms of avidin binding to biotinylated lipid in Langmuir-Blodgett (LB) monolayers. The MCS-derived cooperativity coefficients and intrinsic association constants for avidin-biotin binding to LB films are correlated strongly (R2 > 0.93) with the binding parameters determined from the same experimental data by a thermodynamic equilibrium binding model (Zhao et al. 1993. Langmuir. 9:3166-3173). This result shows MCS to be an accurate and potentially more versatile method for characterizing biomolecular interactions at surfaces.

Algorithms↗

Quantitative analysis of variable-angle total internal reflection fluorescence microscopy (VA-TIRFM) of cell/substrate contacts.

Variable-angle total internal reflection fluorescence microscopy (VA-TIRFM) allows controlled variation of the illumination depth with the potential of measuring both membrane/substrate separation distances and sizes of focal contacts. VA-TIRFM images are collected from well-spread bovine aortic endothelial cells (BAEC) stained with a membrane-bound carbocyanine dye. Quantitative determination of absolute membrane/substrate separation distances and individual focal contact area are attempted using a simplified model of TIRFM optics. For angles slightly greater than the critical angle of 64 degrees, both the dorsal and ventral membranes were illuminated, while images excited above 66 degrees illuminated only focal contacts. Above 74 degrees the fluorescence of focal contacts was dominated by back-ground noise. Direct application of the simplified optical model without accounting for background intensity was unsatisfactory. However, correction for background fluorescence and nonlinear regression of the untransformed data over the working range yielded focal contact separation distances of 24 +/- 13 nm. Focal contact areas estimated by TIRFM (1.3 +/- 0.7 micron2) agreed closely with areas observed by immunofluorescence staining of vinculin (1.5 +/- 0.3 microns2).

Animals↗

Polyimides as biomaterials: preliminary biocompatibility testing.

A number of commercially available polyimide materials were evaluated in vitro using a selected battery of levels I and II testing protocols prescribed by the National Institutes of Health Guidelines for Blood-Material Interactions. These procedures consisted of electron spectroscopy for chemical analysis and contact angle characterization surface studies, and protein adsorption, cell culture cytotoxicity, clotting time and haemolysis biocompatibility testing. The polyimide surfaces were invariant from the bulk composition with 60-80% C, 10-20% O and 2-5% N, producing advancing contact angles in the hydrophobic range (80-100 degrees). Consequently, they adsorbed significant amounts of albumin (2-3 micrograms/cm2) and fibrinogen (0.5-0.8 microgram/cm2). The polyimides also displayed an insignificant level of cytotoxicity and haemolysis, and clotting times ranged from 63 to 98% of normal. These clotting times and haemolytic index values were intermediate between the values observed for Teflon and Silastic controls. These factors, along with the strong adherence of polyimides to metal oxide substrates, indicate that polyimide materials are good candidates for further testing as encapsulants for implantable biosensors.

3T3 Cells↗

Total internal reflection fluorescence microscopy (TIRFM). II. Topographical mapping of relative cell/substratum separation distances.

A simplified model of TIRF optics was used to quantitate the relative membrane/substratum separation distances from the spatial pattern of TIRF image brightness. Phase-contrast and total internal reflection fluorescence microscopy (TIRFM) images were collected of bovine aortic endothelial cells (BAEC) plated onto glass microscope slides for 15 min, 30 min and 24 h. BAEC adherent for 15 min showed an absence of a focal contact morphology, with the region of closest apposition beneath the cell center. After 30 min, multiple contacts with the surface were established and the morphology became more irregular. BAEC attached for 24 h showed well-defined focal contact regions aligned in characteristically striated patterns. The relative distance between closest and farthest membrane/substratum separations are consistent with reported distance between focal and matrix contacts. Topographical maps of membrane/substratum separation distances over the entire ventral surface of the plated cells were constructed to demonstrate the utility of quantitative TIRF microscopy.

Animals↗

Integrated optical attenuated total reflection spectrometry of aqueous superstrates using prism-coupled polymer waveguides.

Attenuated total reflection (ATR) spectrometry of aqueous solutions in contact with polystyrene integrated optical waveguides has been investigated. The mode-dependent absorption of evanescent energy by fluorescein solutions adjacent to the waveguide surface was measured and compared to theoretical predictions based on a ray optics approach. Although enhanced sensitivity was observed with increasing mode number, the sensitivity for the highest order mode was less than that predicted by theory.

Chemistry Techniques, Analytical↗

Total internal reflection fluorescence (TIRF) microscopy. I. Modelling cell contact region fluorescence.

Total Internal Reflection Fluorescence (TIRF) is a powerful technique for visualizing focal and close contacts between the cell and the surface. Practical application of TIRF has been hampered by the lack of straightforward methods to calculate separation distances. The characteristic matrix theory of thin dielectric films was used to develop simple exponential approximations for the fluorescence excited in the cell-substratum contact region during a TIRF experiment. Two types of fluorescence were examined: fluorescently labeled cell membranes, and a fluorescent water-soluble dye. By neglecting the refractive index of the cell membrane, the fluorescence excited in the cell membrane was modelled by a single exponential function while the fluorescence in the membrane/substratum water gap followed a weighted sum of two exponentials. The error associated with neglecting the cell membrane for an incident angle of 70 degrees never exceeded 2.5%, regardless of the cell-substratum separation distance. Comparisons of approximated fluorescence intensities to more exact solutions of the fluorescence integrals for the three-phase model indicated that the approximations are accurate to about 1% for membrane/substratum gap thicknesses of less than 50 nm if the cytoplasmic and water gap refractive indices are known. The intrinsic error of this model in the determination of membrane/substratum separations was 10% as long as the uncertainties in the water gap and cytoplasmic refractive indices were less than 1%.

Cell Adhesion↗

Thrombogenesis: effect of molecular motions, surface order, and hydrophobicity of the polymer interface.

The effect and interrelationship between primary and secondary molecular motions, morphological order/disorder, and associated water on thrombogenesis are elucidated using an amorphous hydrophobic polymer of poly[trifluoroethoxy) ( fluoroalkoxy ) phosphazene ], a semicrystalline triblock copolymer of poly[(gamma-benzyl-L-glutamate) (acrylonitrile/butadiene) (gamma-benzyl-L-glutamate)] and a surface cross-linked hydrophilic/hydrophobic(core)/hydrophilic triblock copolymer of poly[(hydroxy propyl glutamine) (gamma-benzyl-L-glutamate) (hydroxy propyl glutamine)]. The thrombogenic response of the polymers indicated that for a semicrystalline polymer an epitaxial model can be employed to correlate and interrelate the ultrastructure morphology, surface chemistry, surface molecular motions, degrees and types of associated bound water and surface/subsurface ion binding to thrombogenesis. Further for an amorphous polymer, of given side chain length and chemistry, the results indicate that there is an initial effect of molecular motions on thrombogenesis, independent of morphological order/disorder and/or associated water.

Animals↗

Polyphosphazenes: effect of molecular motions on thrombogenesis.

The effect and interrelationship between primary (segmental backbone) and secondary (side chain) molecular motions on thrombogenesis, independent of morphological order/disorder, crystallinity, and/or associated water is elucidated using an amorphous hydrophobic polymer of poly-[(trifluoroethoxy) (fluoroalkoxy)phosphazene] PNF. The results indicate that thrombogenesis for an amorphous hydrophobic polymer is sensitive and dependent on the degrees and types of primary and secondary molecular motions at the polymer interface.

Animals↗

Characterization of implantable biosensor membrane biofouling.

The material-tissue interaction that results from sensor implantation is one of the major obstacles in developing viable, long-term implantable biosensors. Strategies useful for the characterization and modification of sensor biocompatibility are widely scattered in the literature, and there are many peripheral studies from which useful information can be gleaned. The current paper reviews strategies suitable for addressing biofouling, one aspect of biosensor biocompatibility. Specifically, this paper addresses the effect of membrane biofouling on sensor sensitivity from the standpoint of glucose transport limitations. Part I discusses the in vivo and in vitro methods used to characterize biofouling and the effects of biofouling on sensor performance, while Part II presents techniques intended to improve biosensor biocompatibility.

Biocompatible Materials↗

Protein patterning.

The current technology available for patterning proteins is reviewed. Examples of two-dimensional protein patterning using conventional photolithographic methods, photochemistry, and self-assembled monolayers are given. Consideration is also given to some major issues affecting protein patterning, including non-specific binding, protein pattern uniformity, and measurement techniques. S-layer nanopatterning and three-dimensional biochip patterning are discussed in possible future directions. In addition, a discussion of the impact of protein patterning technology on the field of biomaterials is discussed.

Biotechnology↗

Imaging of cell/substrate contacts on polymers by total internal reflection fluorescence microscopy.

A simplified model of total internal reflection fluorescence (TIRF) emission of fluorescently labeled cell membranes [Reichert, W. M.; Truskey, G. A. J. Cell Sci. 1990, 96, 219-230] was used to determine the topography of the cell membrane in apposition to a polymer-coated surface. The homopolymer substrates were spun cast films of hydrophilic poly(hydroxyethyl methacrylate) (polyHEMA) or hydrophobic poly(ethyl methacrylate) (polyEMA). Bovine aortic endothelial cells (BAEC) on preadsorbed fibronectin polymer substrates were either plated for 24 h, fixed, labeled, and examined by TIRF microscopy (TIRFM) and phase-contrast microscopy or plated for 2 h and tested for their adhesion strength in a parallel-plate flow chamber. BAEC attached to polyHEMA showed no evidence of focal contact formation. However, BAEC attached to polyEMA were well spread and showed an array of focal contacts. TIRFM data were transformed to construct a detailed topographical map of relative cell/substrate separation distances. Virtually all of the BAEC plated to polyHEMA were sheared from the surface when subjected to a 50 dyn/cm2 burst of laminar flow, whereas only 10% of the BAEC were sheared from the polyEMA surface. These data suggest that the polyHEMA and polyEMA surface properties (e.g., hydrophobicity) correlate with the presence of BAEC focal contacts and the BAEC attachment strength.

Animals↗

Short-term cell/substrate contact dynamics of subconfluent endothelial cells following exposure to laminar flow.

The manner in which fluid stresses are transmitted from the apical to the basal surface of the endothelium will influence the dynamics of cell/substrate contacts. Such dynamics could be important in the design of synthetic vascular grafts to promote endothelial cell adhesion. To examine whether the initial response of cell/substrate contact sites to flow depends on the magnitude of the applied shear stress, subconfluent monolayers of endothelial cells were exposed to flow at 10, 20, and 30 dyn cm-2 wall shear stresses for 20 min. Cell/substrate contact sites were visualized with total internal reflection fluorescence microscopy. Flow induced a rapid fluctuation in the membrane topography, which was reflected in dynamic changes in cell/substrate contacts. Exposure to flow caused marked changes in contact area. Contact movement occurred normal and parallel to the direction of flow. Contact sites demonstrated significant variability in contact area at 30 dyn cm-2 during the experiment but no significant movement of the contact sites in flow direction after 20 min of flow. Mean square displacements of the contact center of mass were described in terms of a directed diffusion model. Prior to onset of flow, contact movement was random. Flow induced a significant convective component to contact movement for 300-600 s, followed by reestablishment of diffusive growth and movement of contacts. These results suggest that fluid stresses are rapidly transmitted from the apical to the basal surface of the cell via the cytoskeleton.

Animals↗