MR imaging of chronic osteomyelitis.

Magnetic resonance (MR) at 1.5 T was used preoperatively and prior to aspiration to determine extent and location of infection in eight patients with chronic osteomyelitis. There was excellent correlation between MR and surgical findings in all cases. Infected areas, both intraosseous and extraosseous, displayed increased signal intensity on T2-weighted images. Sequestra, sinus tracts, and soft tissue abscesses were seen. By directly imaging foci of infection MR may have certain advantages over CT and scintigraphy in the evaluation of chronic osteomyelitis.

Chronic Disease↗

Juxtaacetabular ganglionic (or synovial) cysts: CT and MR features.

Radiographic findings include supraacetabular bone erosions, subchondral acetabular cysts, soft tissue masses with or without radiolucent inclusions representing nitrogen gas, joint space narrowing, and abnormal hip configuration. Associated tears of the acetabular labrum were confirmed by arthrography in two patients. Computed tomography and magnetic resonance imaging afforded improved delineation of soft tissue ganglia and their relationship to the acetabular bone, labrum, and hip joint. We report our experience with seven patients in whom various imaging examinations clearly documented the presence of soft tissue cystic lesions adjacent to the acetabulum; in six of the seven patients, significant clinical manifestations were evident in the affected hip. Such cysts, whether designated synovial or ganglionic in type, appear to be a frequently overlooked yet important cause of hip symptomatology.

Acetabulum↗

Automated testing of arrhythmia monitors using annotated databases.

Arrhythmia-algorithm performance is typically tested using the AHA and MIT/BIH databases. The tools for this test are simulation software programs. While these simulations provide rapid results, they neglect hardware and software effects in the monitor. To provide a more accurate measure of performance in the actual monitor, a system has been developed for automated arrhythmia testing. The testing system incorporates an IBM-compatible personal computer, a digital-to-analog converter, an RS232 board, a patient-simulator interface to the monitor, and a multi-tasking software package for data conversion and communication with the monitor. This system "plays" patient data files into the monitor and saves beat classifications in detection files. Tests were performed using the MIT/BIH and AHA databases. Statistics were generated by comparing the detection files with the annotation files. These statistics were marginally different from those that resulted from the simulation. Differences were then examined. As expected, the differences were related to monitor hardware effects.

Algorithms↗