Small-angle x-ray scattering studies of human breast tissue samples.

Small-angle x-ray scattering (SAXS) patterns are recorded from thin breast tissue samples containing healthy and cancerous regions. The SAXS patterns are compared with histo-pathological observations. The information available from SAXS is reviewed, and a model for scattering from collagen is presented. Scattering patterns of collagen at regions far from the tumours are essentially different from those at tumours. The axial period of collagen fibrils is 65.0 +/- 0.1 nm in healthy regions, and 0.3 nm larger in cancer-invaded regions. The average intensity of scattering from cancerous regions is an order of magnitude higher than the intensity from healthy regions. This is interpreted to arise from an increase of the specific surface area of the scatterers, which is due to a disruption of the molecular and supra-molecular structures in cancerous regions and invasion of new types of cells. The differences of the SAXS patterns are large and distinctive enough to suggest that these phenomena may be utilized in mammography.

Breast↗

Diffraction enhanced imaging contrast mechanisms in breast cancer specimens.

We have investigated the contrast mechanisms of the refraction angle, and the apparent absorption images obtained from the diffraction enhanced imaging technique (DEI) and have correlated them with the absorption contrast of conventional radiography. The contrast of both the DEI refraction angle image and the radiograph have the same dependence on density differences of the tissues in the visualization of cancer; in radiography these differences directly relate to the contrast while in the DEI refraction angle image it is the density difference and thickness gradient that gives the refraction angle. We show that the density difference of fibrils in breast cancer as measured by absorption images correlate well with the density difference derived from refraction angle images of DEI. In addition we find that the DEI apparent absorption image and the image obtained with the DEI system at the top of the reflectivity curve have much greater contrast than that of the normal radiograph (x8 to 33-fold higher). This is due to the rejection of small angle scattering (extinction) from the fibrils enhancing the contrast.

Absorption↗

Lack of cell death enhancement after irradiation with monochromatic synchrotron X rays at the K-shell edge of platinum incorporated in living SQ20B human cells as cis-diamminedichloroplatinum (II).

In this paper we describe the results of experiments using synchrotron radiation to trigger the Auger effect in living human cancer cells treated with a widely used chemotherapy drug: cis-diamminedichloroplatinum (II) (cisplatin). The experiments were carried out at the ID17 beamline of the European Synchrotron Radiation Facility, which produces a high-fluence monochromatic beam that is adjustable from 20 to 80 keV. Cisplatin was chosen as the carrier of platinum atoms in the cells because of its alkylating-like activity and the irradiation was done with monochromatic beams above and below the platinum K-shell edge (78.39 keV). Cell survival curves were comparable with those obtained for the same cells under conventional irradiation conditions. At a low dose of cisplatin (0.1 microM, 48 h), no difference was seen in survival when the cells were irradiated above and below the K-shell edge of platinum. Higher cisplatin concentrations were investigated to enhance the cellular platinum content. The results with 1 microM cisplatin for 12 h showed no difference when the cells were irradiated with beams above or below the platinum K-shell edge with the exception of the higher cell death resulting from drug toxicity. The intracellular content of platinum was significant, as measured macroscopically by inductively coupled plasma mass spectrometry. Its subcellular localization and particularly its presence in the cell nucleus were verified by microscopic synchrotron X-ray fluorescence. This was the first known attempt at K-shell edge photon activation of stable platinum in living cells with a platinum complex used for chemotherapy. Its evident toxicity in these cells leads us to put forth the hypothesis that cisplatin toxicity can mask the enhancement of cell death induced by the irradiation above the K-shell edge. However, K-shell edge photon activation of stable elements provides a powerful technique for the understanding of the biological effects of Auger processes. Further avenues of development are discussed.

Calibration↗

Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent.

Small airways play a key role in the distribution of ventilation and in the matching of ventilation to perfusion. The purpose of this study was to introduce an imaging method that allows measurement of regional lung ventilation and evaluation of the function of airways with a small diameter. The experiments were performed at the Medical Beamline of the European Synchrotron Radiation Facility. Monochromatic synchrotron radiation beams were used to obtain quantitative respiration-gated images of lungs and airways in two anaesthetized and mechanically ventilated rabbits using inhaled stable xenon (Xe) gas as a contrast agent. Two simultaneous images were acquired at two different energies, above and below the K-edge of Xe. Logarithmic subtraction of the two images yields absolute Xe concentrations. This technique is known as K-edge subtraction (KES) radiography. Two-dimensional planar and CT images were obtained showing spatial distribution of Xe concentrations within the airspaces, as well as the dynamics of filling with Xe. Bronchi down to 1 mm in diameter were visible both in the subtraction radiographs and in tomographic images. Absolute concentrations of Xe gas were calculated within the tube carrying the inhaled gas mixture, small and large bronchi, and lung tissue. Local time constants of ventilation with Xe were obtained by following the evolution of gas concentration in sequential computed tomography images. The results of this first animal study indicate that KES imaging of lungs with Xe gas as a contrast agent has great potential in studies of the distribution of ventilation within the lungs and of airway function, including airways with a small diameter.

Administration, Inhalation↗

First human transvenous coronary angiography at the European Synchrotron Radiation Facility.

The first operation of the European Synchrotron Radiation Facility (ESRF) medical beamline is reported in this paper. The goal of the angiography project is to develop a reduced risk imaging technique, which can be used to follow up patients after coronary intervention. After the intravenous injection of a contrast agent (iodine) two images are produced with monochromatic beams, bracketing the iodine K-edge. The logarithmic subtraction of the two measurements results in an iodine enhanced image, which can be precisely quantified. A research protocol has been designed to evaluate the performances of this method in comparison with the conventional technique. Patients included in the protocol have previously undergone angioplasty. If a re-stenosis is suspected, the patient is imaged both at the ESRF and at the hospital with the conventional technique, within the next few days. This paper reports the results obtained with the first patients. To date, eight patients have been imaged and excellent image quality was obtained.

Angioplasty, Balloon, Coronary↗

Research at the European Synchrotron Radiation Facility medical beamline.

The application of synchrotron radiation in medical research has become a mature field of research at synchrotron facilities worldwide. In the relatively short time that synchrotrons have been available to the scientific community, their characteristic beams of UV and X-ray radiation have been applied to virtually all areas of medical science which use ionizing radiation. The ability to tune intense monochromatic beams over wide energy ranges differentiates these sources from standard clinical and research tools. At the European Synchrotron Radiation Facility (Grenoble, France), a major research facility is operational on an advanced wiggler radiation beamport, ID17. The beamport is designed to carry out a broad range of research ranging from cell radiation biology to in vivo human studies. Medical imaging programs at ID17 include transvenous coronary angiography, computed tomography, mammography and bronchography. In addition, a major research program on microbeam radiation therapy is progressing. This paper will present a very brief overview of the beamline and the imaging and therapy programs.

Animals↗

In vivo K-edge imaging with synchrotron radiation.

We present in this paper two imaging techniques using contrast agents assessed with in vivo experiments. Both methods are based on the same physical principle, and were implemented at the European Synchrotron Radiation Facility medical beamline. The first one is intravenous coronary angiography using synchrotron radiation X-rays. This imaging technique has been planned for human studies in the near future. We describe the first experiments that were carried out with pigs at the ESRF. The second imaging mode is computed tomography using synchrotron radiation on rats bearing brain tumors. Owing to synchrotron radiation physical properties, these new imaging methods provide additional information compared to conventional techniques. After infusion of the contrast agent, it is possible to derive from the images the concentration of the contrast agent in the tumor area for the computed tomography and in any visible vessel for the angiography method.

Animals↗

Diffraction enhanced x-ray imaging.

Diffraction enhanced imaging is a new x-ray radiographic imaging modality using monochromatic x-rays from a synchrotron which produces images of thick absorbing objects that are almost completely free of scatter. They show dramatically improved contrast over standard imaging applied to the same phantom. The contrast is based not only on attenuation but also the refraction and diffraction properties of the sample. This imaging method may improve image quality for medical applications, industrial radiography for non-destructive testing and x-ray computed tomography.

Biophysical Phenomena↗

Monochromatic energy-subtraction radiography using a rotating anode source and a bent Laue monochromator.

A system for area-beam energy-subtraction monochromatic radiography was developed and tested. It utilizes a bent Laue crystal monochromator developed at the National Synchrotron Light Source (NSLS), and a compact rotating anode X-ray source developed at the Science Research Laboratory (SRL). The K(alpha) characteristic lines (both K(alpha 1) and K(alpha 2) of the cerium and barium targets were diffracted by the monochromator and used for the above- and below-K-edge imaging, respectively, of phantoms with iodine contrast agents. Digital subtraction of the images produced an iodine image.

Angiography, Digital Subtraction↗