Diffraction enhanced x-ray imaging.

Abstract

Diffraction enhanced imaging is a new x-ray radiographic imaging modality using monochromatic x-rays from a synchrotron which produces images of thick absorbing objects that are almost completely free of scatter. They show dramatically improved contrast over standard imaging applied to the same phantom. The contrast is based not only on attenuation but also the refraction and diffraction properties of the sample. This imaging method may improve image quality for medical applications, industrial radiography for non-destructive testing and x-ray computed tomography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Chapman, W Thomlinson, R E Johnston, D Washburn, E Pisano, N Gmür, Z Zhong, R Menk, F Arfelli, D Sayers. 1997. Diffraction enhanced x-ray imaging.. https://doi.org/10.1088/0031-9155%2F42%2F11%2F001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stochastic fractal behavior in concentration fluctuation and fluorescence correlation spectroscopy.

Fluctuations in the concentration of Brownian particles in one and two dimensions, or any reasonable measurement of the concentration such as in fluorescence correlation spectroscopy, is shown to be a stochastic fractal with a long tail. Being singular at omega = 0, the power spectrum of the fluctuation S(omega) approximately omega-1/2 for diffusion in one dimension, approximately log omega in two dimensions, but non-singular in three dimensions. This discovery provides one simple physical mechanism for possible long-memory fractal behavior, and its implications to various biological processes are discussed.

Biophysical Phenomena

Modular gradient coil: A new concept in high-performance whole-body gradient coil design.

A new concept in high-performance MR gradient coil design is presented which we have called the Modular Gradient Coil (MGC). This novel design approach results in an actively shielded whole-body gradient coil containing multiple and independent elements, integrated onto a single former, for generating gradient fields along each of the three axes (x, y, and z). These elements can be energized in a number of configurations, using a single gradient power supply unit (PSU), to generate a whole range of gradient performance levels. The design criteria for the MGC also include a requirement to prohibit peripheral nerve stimulation in all of its modes of operation. This requirement is achieved, while simultaneously providing high performance, by specifying different volumes of gradient linearity for each of the operating modes. Magn Reson Med 42:561-570, 1999.

Biophysical Phenomena