PubMed Health⌕ Search

Biomedical subjects

Wayne M Mullett

Publications and source records attributed to Wayne M Mullett.

8 recordsLinked to original sources

Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis.

The analysis of drugs in various biological fluids is an important criterion for the determination of the physiological performance of a drug. After sampling of the biological fluid, the next step in the analytical process is sample preparation. The complexity of biological fluids adds to the challenge of direct determination of the drug by chromatographic analysis, therefore demanding a sample preparation step that is often time-consuming, tedious, and frequently overlooked. However, direct on-line injection methods offer the advantage of reducing sample preparation steps and enabling effective pre-concentration and clean-up of biological fluids. These procedures can be automated and therefore reduce the requirements for handling potentially infectious biomaterial, improve reproducibility, and minimize sample manipulations and potential contamination. The objective of this review is to present an overview of the existing literature with emphasis on advances in automated sample preparation methods for liquid-chromatographic methods. More specifically, this review concentrates on the use of direct injection techniques, such as restricted-access materials, turbulent-flow chromatography and other automated on-line solid-phase extraction (SPE) procedures. It also includes short overviews of emerging automated extraction-phase technologies, such as molecularly imprinted polymers, in-tube solid-phase micro-extraction, and micro-extraction in a packed syringe for a more selective extraction of analytes from complex samples, providing further improvements in the analysis of biological materials. Lastly, the outlook for these methods and potential new applications for these technologies are briefly discussed.

Body Fluids↗

Combining restricted access material (RAM) and turbulent flow for the rapid on-line extraction of the cyclooxygenase-2 inhibitor rofecoxib in plasma samples.

Restricted access material (RAM) has been used in the packing of a solid-phase extraction (SPE) column for on-line extractions under turbulent flow conditions. The bio-compatible RAM material works by the principle of size exclusion in addition to conventional reversed-phase chromatography, thereby allowing the extraction and preconcentration of small analyte molecules from biological samples such as plasma. Using small column dimensions (0.76 mm x 50 mm) and a consequently high linear velocity, turbulent flow was achieved during online sample extractions. The improved mass-transfer rate characteristic of turbulent flow allows fast sample cleanup without decreased extraction efficiency. The novel use of the RAM column, connected upstream to a C18 monolithic column, allowed the direct injection, extraction, separation, and MS/MS detection of plasma samples spiked with rofecoxib in a span of 5 min. Calibration curves obtained using this RAM turbulent flow coupled column method showed good linearity (R2 > 0.99) and reproducibility (%RSD < or = 7%). The lower limit of quantitation of rofecoxib in plasma samples was found to be 40 ng/ml. The extraction method showed good recovery of rofecoxib from a plasma matrix with minimal signal loss and robustness after more than 200 plasma injections.

Chromatography, High Pressure Liquid↗

Stir bar sorptive extraction based on restricted access material for the direct extraction of caffeine and metabolites in biological fluids.

A biocompatible stir bar sorptive extraction (SBSE) device was prepared using an alkyl-diol-silica (ADS) restricted access material (RAM) as the SBSE coating. The RAM-SBSE bar was able to simultaneously fractionate the protein component from a biological sample, while directly extracting caffeine and its metabolites, overcoming the present disadvantages of direct sampling in biological matrices by SBSE, such as fouling of the extraction coating by proteins. Desorption of the analytes was performed by stirring the bar in a water/ACN mixture (3/1, v/v) and subsequently reconcentrating the sample solution in water to enable HPLC-UV analysis to be performed. The limit of detection, based on a signal to noise ratio of 3, for caffeine was 25 ng/mL in plasma. The method was confirmed to be linear over the range of 0.5-100 microg/mL of caffeine with an average linear coefficient (R2) value of 0.9981. The injection repeatability and intra-assay precision of the method were evaluated over ten injections, resulting in a %RSD of approximately 8%. The RAM-SBSE device was robust (>50 extraction in plasma without significant signal loss) and simple to use, providing many direct extractions and subsequent determination of caffeine and its metabolites in biological fluids. In contrast to existing sample preparation methods for the analysis of caffeine and selected metabolites in biological fluids, this feasibility study using a biocompatible SBSE approach was advantageous in terms of simplifying the sample preparation procedures.

Caffeine↗

A method for the direct analysis of drug compounds in plasma using a single restricted access material (RAM) column.

We describe an automated approach to analyzing whole plasma samples using online extraction without the need for an analytical column. A single restricted access material (RAM) column provided online extraction and pre-concentration of analytes while effectively removing proteins, salts and other biological materials found in the plasma sample matrix. The reduction in the plasma matrix enabled direct elution of the analytes from the extraction column to the mass spectrometer for selective detection. The precision of the method was evaluated using a proprietary therapeutic agent (Compound A) and was less than 5% over the range of 1-500ng/ml in spiked whole plasma, with an LOQ of 1ng/ml. A side-by-side comparison of RAM results from a pharmacokinetic study in rats was made with a traditional protein precipitation LC-MS method and a correlation of 0.993 was obtained between both methods. The injection-to-injection cycle time for the RAM method was 8min. Further automation was demonstrated by addition and mixing of the internal standard to all samples via an injection program of the autosampler.

Animals↗

Multidimensional on-line sample preparation of verapamil and its metabolites by a molecularly imprinted polymer coupled to liquid chromatography-mass spectrometry.

A new molecularly imprinted polymer (MIP) material was synthesized selective for verapamil and utilized for on-line metabolic screening of this common calcium antagonist in biological samples. Since some metabolites of verapamil have also shown pharmacological properties, a selective and sensitive sample preparation approach that provides a metabolic profile in biologically relevant samples is important. The MIP material was coupled on-line to a restricted access material (RAM) precolumn. The multidimensional nature of this set-up removed large matrix interferents such as proteins from the sample, while the selectivity of the MIP enabled further cleanup of the smaller analytes. The selectivity and extraction efficiency of the MIP for verapamil and its metabolites was evaluated in various biological matrices, such as cell cultures and urine. The experimental set-up with the developed method enabled the direct injection of biological samples for the selective isolation, preconcentration, identification and analysis of verapamil and its phase I metabolites by LC-MS(n). This multidimensional approach provided much qualitative information about the metabolic profile of verapamil in various biological matrices. An analytical method was developed for the quantification of verapamil and gallopamil in urine, plasma and cell culture. Acceptable linearity (R(2)=0.9996, 0.9982 and 0.9762) with an average injection repeatability (n=3) of 10, 25 and 15% R.S.D. was determined for urine, plasma and cell culture, respectively. This is the first application of the procedure for the selective metabolic screening of verapamil in biological samples.

Animals↗

Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum.

A restricted access material (RAM), alkyl-diol-silica (ADS), was used to prepare a highly bio-compatible solid-phase microextraction (SPME) capillary for the automated and direct in-tube extraction of several benzodiazepines from human serum. The bifunctionality of the ADS extraction phase prevented fouling of the capillary by protein adsorption while simultaneously trapping the analytes in the hydrophobic porous interior. This the first report of a restricted access material utilized as an extraction phase for in-tube SPME. The approach simplified the required apparatus in comparison to existing RAM column switching procedures, and more importantly eliminated the excessive use of extraction solvents. The biocompatibility of the ADS material also overcame the existing problems with in-tube SPME that requires an ultrafiltration or other deproteinization step prior to handling biological samples, therefore further minimizing the sample preparation requirements. The calculated oxazepam, temazepam, nordazepam and diazepam detection limits were 26, 29, 22 and 24 ng/ml in serum, respectively. The method was linear over the range of 50-50 000 ng/ml with an average linear coefficient (R2) value of 0.9998. The injection repeatability and intra-assay precision of the method were evaluated with five injections of a 10-microg/ml serum sample (spiked with all compounds), resulting in an average RSD<7%. The ADS extraction column was robust, providing many direct injections of biological fluids for the extraction and subsequent determination of benzodiazepines.

Benzodiazepines↗

Automated in-tube solid-phase microextraction coupled with HPLC for the determination of N-nitrosamines in cell cultures.

An automated in-tube solid-phase microextraction (SPME) HPLC analysis method for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) and several metabolites has been developed. NNK is one of the tobacco-specific N-nitrosamines (TSNA), which has been linked to cancers associated with the use of or exposure to tobacco products. In-tube SPME is an on-line extraction technique in which analytes are extracted and concentrated from the sample directly into a coated capillary by repeated draw/eject steps. In this study, a tailor-made polypyrrole (PPY)-coated capillary and several commercially available capillaries (capillary GC columns) were used to evaluate their extraction efficiencies for NNK and several metabolites in cell cultures. Compared with commercial capillaries that were currently used for in-tube SPME, the PPY-coated capillary showed better extraction efficiency for all of the compounds studied. After optimization of the extraction conditions, NNK and five metabolite compounds were analyzed in spiked cell cultures, confirming the applicability of the developed method. Excellent linearity was observed for all compounds (av R2 = 0.9942) and detection limits that ranged from 20 to 250 ng/mL. The average within-day and between day variations (% RSD) were 2.9 and 3.6%, respectively. This automated extraction and analysis method simplified the determination of the TSNA, requiring a total sample analysis time of only approximately 30 min.

Animals↗

Direct determination of benzodiazepines in biological fluids by restricted-access solid-phase microextraction.

A biocompatible solid-phase microextraction (SPME) fiber was prepared using an alkyl-diol-silica (ADS) restricted-access material as the SPME coating. The ADS-SPME fiber was able to simultaneously fractionate the protein component from a biological sample, while directly extracting several benzodiazepines, overcoming the present disadvantages of direct sampling in biological matrixes by SPME. The fiber was interfaced with an HPLC-UV system, and an isocratic mobile phase was used to desorb, separate, and quantify the extracted compounds. The calculated clonazepam, oxazepam, temazepam, nordazepam, and diazepam detection limits were 600, 750, 333, 100, and 46 ng/mL in urine, respectively. The method was confirmed to be linear over the range of 500-50000 ng/mL with an average linear coefficient (R2) value of 0.9918. The injection repeatability and intraassay precision of the method were evaluated over 10 injections, resulting in a RSD of approximately 6%. The ADS-SPME fiber was robust and simple to use, providing many direct extractions and subsequent determination of benzodiazepines in biological fluids.

Anti-Anxiety Agents↗