PubMed Health⌕ Search

PubMed · 12187987

Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum.

Abstract

A restricted access material (RAM), alkyl-diol-silica (ADS), was used to prepare a highly bio-compatible solid-phase microextraction (SPME) capillary for the automated and direct in-tube extraction of several benzodiazepines from human serum. The bifunctionality of the ADS extraction phase prevented fouling of the capillary by protein adsorption while simultaneously trapping the analytes in the hydrophobic porous interior. This the first report of a restricted access material utilized as an extraction phase for in-tube SPME. The approach simplified the required apparatus in comparison to existing RAM column switching procedures, and more importantly eliminated the excessive use of extraction solvents. The biocompatibility of the ADS material also overcame the existing problems with in-tube SPME that requires an ultrafiltration or other deproteinization step prior to handling biological samples, therefore further minimizing the sample preparation requirements. The calculated oxazepam, temazepam, nordazepam and diazepam detection limits were 26, 29, 22 and 24 ng/ml in serum, respectively. The method was linear over the range of 50-50 000 ng/ml with an average linear coefficient (R2) value of 0.9998. The injection repeatability and intra-assay precision of the method were evaluated with five injections of a 10-microg/ml serum sample (spiked with all compounds), resulting in an average RSD<7%. The ADS extraction column was robust, providing many direct injections of biological fluids for the extraction and subsequent determination of benzodiazepines.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wayne M Mullett, Karsten Levsen, Dieter Lubda, Janusz Pawliszy. 2002-07-19. Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum.. https://doi.org/10.1016/s0021-9673(02)00216-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Molecularly imprinted solid-phase extraction of diazepam and its metabolites from hair samples.

An anti-diazepam, molecularly imprinted polymer (MIP) has been synthesized and used to extract diazepam and other benzodiazepines from hair samples via a molecularly imprinted solid-phase extraction (MISPE) protocol. Optimum retention of diazepam on the MIP columns was achieved using an apolar solvent, and the binding capacity of the polymer toward diazepam was found to be 110 ng of diazepam/mg of polymer. The recovery of a 50 ng diazepam standard spiked into blank hair was 93%, with good precision (RSD = 1.5%). The LOD and LOQ of diazepam in spiked hair samples were 0.09 and 0.14 ng/mg, respectively. The MISPE method was demonstrated to be applicable to the analysis of diazepam metabolites and other benzodiazepine drugs, in addition to diazepam itself. The application of the extraction method to postmortem hair samples yielded results that were in good agreement with the corresponding ELISA data (from blood samples) and data arising from the analysis of the same blood samples using a validated in-house SPE-LC-MS-MS method.

Benzodiazepines↗

Clopidogrel resistance: role of body mass and concomitant medications.

INTRODUCTION: Platelets have a central role in the development of arterial thrombosis and subsequent cardiovascular events. An appreciation of this has made antiplatelet therapy the cornerstone of cardiovascular disease management. Recent studies have described the phenomenon of clopidogrel resistance but the possible mechanisms are still unclear. PATIENTS AND METHODS: The aim of this study was to compare the characteristics (risk profile, previous diseases, medications, hemorheological variables and plasma von Willebrand factor and soluble P-selectin levels) of patients in whom clopidogrel provided effective platelet inhibition with those in whom clopidogrel was not effective in providing platelet inhibition. 157 patients with chronic cardio- and cerebrovascular diseases (83 males, mean age 61+/-11 yrs, 74 females, 63+/-13 yrs) taking 75 mg clopidogrel daily (not combined with aspirin) were included in the study. RESULTS: Compared with clopidogrel-resistant patients (35 patients (22%), patients who demonstrated effective clopidogrel inhibition had a significantly lower BMI (26.1 vs. 28.8 kg/m2, p<0.05). Patients with ineffective platelet aggregation were significantly more likely to be taking benzodiazepines (25% vs. 10%) and selective serotonin reuptake inhibitors (28% vs. 12%) (p<0.05). After an adjustment to the risk factors and medications BMI (OR 2.62; 95% CI: 1.71 to 3.6; p<0.01), benzodiazepines (OR 5.83; 95% CI: 2.53 to 7.1; p<0.05) and SSRIs (OR 5.22; 95% CI: 2.46 to 6.83; p<0.05) remained independently associated with CLP resistance. There was no significant difference in the rheological parameters and in the plasma levels of adhesive molecules between the two examined groups. CONCLUSION: The background of ineffective clopidogrel medication is complex. Drug interactions may play a role on clopidogrel bioavailability, on the other hand, the significant difference in BMI between the two examined groups suggests that clopidogrel therapy should be weight-adjusted.

Benzodiazepines↗