PubMed Health⌕ Search

Biomedical subjects

Werner Bautz

Publications and source records attributed to Werner Bautz.

At least 19 recordsLinked to original sources

Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation.

BACKGROUND: Multidetector computed tomographic angiography (MDCT) has been shown to allow detection of coronary artery bypass graft (CABG) occlusions and stenoses. However, the assessment of native coronary arteries in addition to CABG has thus far not been sufficiently validated. METHODS AND RESULTS: Fifty patients with a total of 138 CABG (34 mammary grafts, 3 radial grafts, 101 venous grafts) were investigated by MDCT (0.6-mm collimation, 32 detector rows, 2 focal points, 330-ms rotation) 9 to 252 months (mean, 106 months) after surgery. CABG and all native coronary arteries with a diameter of > 1.5 mm were evaluated for the presence of significant stenoses (> or = 50% diameter reduction). Results were compared with quantitative coronary angiography. By MDCT, all CABG were evaluable and were correctly classified as occluded (n=38) or patent (n=100). Sensitivity for stenosis detection in patent grafts was 100% (16/16) with a specificity of 94% (79/84). For the per-segment evaluation of native coronary arteries and distal runoff vessels, sensitivity in evaluable segments (91%) was 86% (87/101) with a specificity of 76% (354/465). If evaluation was restricted to nongrafted arteries and distal runoff vessels, sensitivity was 86% (38/44) with a specificity of 90% (302/334). On a per-patient basis, classifying patients with at least 1 detected stenosis in a CABG, a distal runoff vessel, or a nongrafted artery or with at least 1 unevaluable segment as "positive," MDCT yielded a sensitivity of 97% (35/36) and specificity of 86% (12/14). CONCLUSIONS: We found that 64-slice MDCT permits the evaluation of bypass grafts and the assessment of the native coronary arteries for the presence of stenosis.

Adult↗

Contrast enhanced sonography of the gallbladder: a tool in the diagnosis of cholecystitis?

RATIONALE AND OBJECTIVES: To evaluate if contrast enhanced sonography (CES) can help to detect gallbladder inflammation and differentiate between acute and chronic cholecystitis. MATERIALS AND METHODS: Thirty-three patients with clinical suspicion of acute cholecystitis were examined with CES before cholecystectomy. Thirty patients with no history of gallbladder disease served as control. CES was performed using 2.5 mL SonoVue. A small mechanical index was chosen (0.1). The enhancement pattern of the gallbladder was ranked in a three-point scale: no enhancement, low enhancement and strong enhancement. 28/33 patients underwent surgery. Sonographic findings were compared to histological results. RESULTS: In 16/20 cases with histological proven acute cholecystitis, the gallbladder wall showed a strong enhancement. Low enhancement was found in four patients with acute and in six patients with chronic cholecystitis. The gallbladder wall of two patients with chronic inflammation and all patients (30/30) of the control group showed no enhancement. CONCLUSION: CES is a feasible tool for detecting gallbladder inflammation. Differentiating between acute and chronic cholecystitis seems to be possible.

Acute Disease↗

Assessment of coronary artery stent restenosis by 64-slice multi-detector computed tomography.

AIMS: We investigated the feasibility of assessing coronary artery stent restenosis using a new generation 64-slice multi-detector computed tomography-scanner (MDCT) in comparison to conventional quantitative angiography. METHODS AND RESULTS: MDCT was performed in 64 consecutive patients (mean age 58+/-10 years) with previously implanted coronary artery stents (102 stented lesions: mean stent diameter 3.17+/-0.38 mm). Each stent was classified as 'evaluable' or 'unevaluable', and in evaluable stents, the presence of in-stent restenosis (diameter reduction >50%) was determined visually. Results were verified against invasive, quantitative coronary angiography. Fifty-nine stented lesions (58%) were classified as evaluable in MDCT. The mean diameter of evaluable stents was 3.28+/-0.40 mm, whereas the mean diameter of non-evaluable stents was 3.03+/-0.31 mm (P=0.0002). Overall, six of 12 in-stent restenoses were correctly detected by MDCT [50% sensitivity (confidence interval 22-77%)] and in 51 of 90 lesions, in-stent restenosis was correctly ruled out [57% specificity (46-67%)]. In evaluable stents, six of seven in-stent restenoses were correctly detected, and the absence of in-stent stenosis was correctly identified in 51 of 52 cases [sensitivity 86% (42-99%) and specificity 98% (88-100%)]. CONCLUSION: Stent type and diameter influence evaluability concerning in-stent restenosis by MDCT. The rate of assessable stents is low, but in evaluable stents, accuracy for detection of in-stent restenosis can be high.

Coronary Restenosis↗

Influence of mammographic density on the diagnostic accuracy of tumor size assessment and association with breast cancer tumor characteristics.

PURPOSE: The accuracy of breast cancer staging involves the estimation of the tumor size for the initial decision-making in the treatment. We investigated the accuracy of tumor size estimation and the association between tumor characteristics and breast density (BD). MATERIALS AND METHODS: A total of 434 women with a primary diagnosis of breast cancer were included in this prospective study at a specialist breast unit. Estimated tumor characteristics included tumor size, nodal status, estrogen/progesterone receptor status, Ki-67, HER2/neu, vascular invasion. Radiomorphological data included tumor size as assessed by mammography, breast ultrasonography, and clinical examination, and American College of Radiology (ACR) categories for BD. RESULTS: BD did not have a significant impact on the assessment of tumor size using breast ultrasound (deviation from ACR categories 1-4: 0.55-0.68 cm; P=0.331). The deviation in mammography was significantly different dependent on BD (0.42-0.9 cm; P<0.001). The clinical examination was not affected by BD. Age and tumor size were the only parameters associated with a denser breast in the multivariate analysis. Older women were less likely to have dense breasts (odds ratio 0.157 for women aged >or=70 years), and patients with larger tumors were less likely to have dense breasts (adjusted OR 0.36 for tumors>2 cm). CONCLUSION: Breast ultrasonography is more accurate than mammography for assessing tumor size in breasts with a higher BD. The difference in tumor size assessment needs to be taken into consideration in the design of clinical trials and treatment decisions.

Analysis of Variance↗

Coronary artery bypass graft (CABG) patency: assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography.

PURPOSE: To investigate the ability of 16-slice multidetector-row computed tomography (MDCT) to visualize coronary artery bypass graft (CABG) patency and to detect bypass stenoses. MATERIALS AND METHODS: Thirty-two patients with 94 grafts (20 mammary artery grafts, 74 venous grafts) were investigated by 16-slice MDCT using a scan protocol with 12 x 0.75 mm slice collimation (pitch 0.3), 420 ms rotation time and simultaneous electrocardiogram (ECG)-registration. One hundred milliliters iodinated contrast agent were injected with a delay according to the individually determined contrast agent transit time. Patients with heart rates above 60 bpm received oral beta-blockade. Cross-sectional images with a slice width of 1.0 mm (0.5 mm increment) were reconstructed using an ECG-gated half-scan reconstruction or a multisegment reconstruction algorithm depending on the heart rate. Bypass grafts were evaluated concerning patency and presence of stenoses > or = 50% diameter reduction on cross-sectional images, multiplanar reformations and maximum intensity projections by two independent observers. Results were compared to coronary bypass angiography. RESULTS: Sixteen-slice MDCT results were compared to those of invasive coronary angiography concerning absence or presence of bypass graft occlusion or relevant stenosis > or = 50% lumen reduction. Coronary CT angiography (CTA) permitted detection of bypass occlusion with 100% sensitivity (28/28) and 98% specificity (64/65). Seventy-eight percent (observer 1) and 84% (observer 2) of all patent grafts were found to be evaluable concerning presence or absence of stenosis. In 34 of 40 (observer 1) and 38 of 43 (observer 2) bypass grafts, high-grade stenoses were correctly ruled out (specificity 85% versus 88%, sensitivity 80% and 82%). Yet, if all patients with either unevaluable grafts/graft anastomosis or relevant graft stenosis were excluded, only 8/32 patients (25%) had fully diagnostic "negative" graft-CTA. According to Kappa statistics, agreement between the observers was 1.0 and 0.93 concerning occlusion and relevant stenosis, respectively. CONCLUSION: Sixteen-slice coronary CTA with sub-millimeter spatial resolution and premedication with oral beta-blockade permits non-invasive assessment of coronary artery bypass grafts with decreasing numbers of unevaluable graft segments. However, patient-based analysis reveals that only a relatively small number of patients ("negative" and completely evaluable graft-CTA) truly profits from noninvasive work-up and could be spared invasive angiography.

Adult↗

Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

UNLABELLED: Multi-detector computed tomography (CT) scanners, by virtue of their high temporal and spatial resolution, permit imaging of the coronary arteries. However, motion artifacts, especially in patients with higher heart rates, can impair image quality. We thus evaluated the performance of a new dual-source CT (DSCT) with a heart rate independent temporal resolution of 83 ms for the visualization of the coronary arteries in 14 consecutive patients. METHODS: Fourteen patients (mean age 61 years, mean heart rate 71 min(-1)) were studied by DSCT. The system combines two arrays of an X-ray tube plus detector (64 slices) mounted on a single gantry at an angle of 90 degrees With a rotation speed of 330 ms, a temporal resolution of 83 ms (one-quarter rotation) can be achieved independent of heart rate. For data acquisition, intraveous contrast agent was injected at a rate of 5 ml/s. Images were reconstructed with 0.75 slice thickness and 0.5 mm increment. The data sets were evaluated concerning visibility of the coronary arteries and occurrence of motion artifact. RESULTS: Visualization of the coronary arteries was successful in all patients. Most frequently, image reconstruction at 70% of the cardiac cycle provided for optimal image quality (50% of patients). Of a total of 226 coronary artery segments, 222 (98%) were visualized free of motion artifact. In summary, DSCT constitutes a promising new concept for cardiac CT. High and heart rate independent temporal resolution permits imaging of the coronary arteries without motion artifacts in a substantially increased number of patients as compared to earlier scanner generations. Larger and appropriately designed studies will need to determine the method's accuracy for detection of coronary artery stenoses.

Artifacts↗

Isotropic reconstruction of SPECT data using OSEM3D: correlation with CT.

RATIONALE AND OBJECTIVES: A statistical based iterative single-photon emission-computed tomography (SPECT) reconstruction algorithm (OSEM) modeling the depth-dependent collimator response in three dimensions has recently been introduced (OSEM3D). The aim of this study was to evaluate the axial shape fidelity of OSEM3D in comparison to OSEM, not taking this variable into account (OSEM2D). MATERIALS AND METHODS: SPECT and separate spiral CT were performed in a phantom containing spheres filled with In-111. In-111-pentetreotide-SPECT and separate spiral-CT imaging were also performed in 22 patients with neuroendocrine tumors. Using window settings adapting the transversal size of the SPECT hot spots to that on CT and the 50% isocontour as boundary, the three-dimensional extensions (dx, dy, dz) of the SPECT representation of the structures under study were measured. These variables were also determined for CT. Furthermore, an index of eccentricity was calculated by averaging the ratios between dz and dx and dz and dy (IE). For isotropically imaged spheres, IE is 1. RESULTS: For OSEM2D, IE was significantly different from 1 in the phantom data (P < .05); this was not the case for OSEM3D and CT. This finding was accounted for by a significantly greater dz on the OSEM2D-SPECT images. In the patient data, dz was by approximately 15.5% greater for OSEM2D than for the other two modalities (P < .05). CONCLUSIONS: The use of OSEM3D avoids deformation of hot SPECT lesions in z-direction. This may be of particular importance in SPECT/CT hybrid imaging capitalizing on the exact match of both modalities.

Algorithms↗

www.tnt-radiology.de: Teach and be taught radiology: implementation of a web-based training program based on user preferences as determined by survery.

RATIONALE AND OBJECTIVES: To create a Web-based training program addressing the needs of a large, heterogeneous audience of users. MATERIALS AND METHODS: We defined our target group as consisting of medical professionals who teach radiology, or who, by their own perception, would benefit from improving their radiologic image interpretation skills. We interviewed 483 members of this group, eliciting their preferences with regard to layout, interactivity, contents, and other categories (11 in total). Considering majority preferences as recommendations and using the help of a special interest group of medical students, we assembled 500 teaching cases over a 1-year period into an interactive training program and made it available on the World Wide Web. RESULTS: Important preferences expressed by majorities of interviewees were: high levels of interactivity, clear layout, intuitive usability, short page load times, permissibility of saving content locally, cost-free access, consideration of user input in the site development. To our knowledge, our web program TNT-Radiology, accessible at , is the first to implement all of these recommendations simultaneously. CONCLUSIONS: We have created a Web-based program usable for teaching and learning radiologic image interpretation that meets the needs of a heterogeneous target audience to an unprecedented extent.

Computer-Assisted Instruction↗

Anatomical accuracy of hybrid SPECT/spiral CT in the lower spine.

AIM: The anatomical accuracy of hardware-based registration of skeletal single photon emission computed tomography (SPECT) and X-ray computerized tomography (CT) has as yet not been studied. The aim of this study was to evaluate this variable in the lower spine for a newly introduced hybrid SPECT/spiral-CT camera. METHODS: In 22 patients referred for degenerative joint disease or tumours, whole-body bone scintigraphy including hybrid SPECT/spiral CT of the lower spine was performed. Subsequent analyses were performed on these pairs of images as well as on data sets obtained after using a rigid automated fusion procedure in addition. Two observers independently measured the distances between the visually determined centres of gravity of the CT and SPECT representation of the fourth and fifth lumbar vertebral body in the X-, Y- and Z-directions (X-, Y- and Z-distances). RESULTS: The distances determined by the two observers for the two vertebral bodies correlated significantly and were averaged for further analysis. For hybrid SPECT/spiral CT without consecutive automated registration, the mean X-, Y- and Z-distances were 1.6+/-1.9 mm, 1.7+/-1.3 mm and 0.9+/-0.5 mm, respectively. Additional automated registration lowered these values to 1.2+/-0.9 mm, 1.1+/-0.7 mm and 0.8+/-0.4 mm, respectively. The difference for the Y-distance proved statistically significant (P<0.05). Additional automated registration significantly reduced the number of subjects in whom at least one of the distances determined was greater than the SPECT pixel size of 4.6 mm from 14% (n=3) to 0% (P<0.05). CONCLUSION: Hardware-based fusion between skeletal SPECT and CT offers a nearly perfect data match in the lower spine. The additional use of a tool for automated rigid registration has the potential to reduce the error of alignment even further and may be useful in patients with reduced compliance leading to movements between the two examinations.

Aged↗

SPECT-guided CT for evaluating foci of increased bone metabolism classified as indeterminate on SPECT in cancer patients.

UNLABELLED: Hybrid cameras combining SPECT and spiral CT offer the opportunity to obtain a diagnostic-quality CT image of scintigraphically suggestive lesions that directly correlates with the SPECT image. The field of view of the CT scan can be adapted on the basis of the SPECT findings ("SPECT-guided CT"). The aim of the present study was to investigate the value of SPECT-guided CT in the assessment of foci of increased bone metabolism classified as indeterminate on SPECT. METHODS: Of 272 consecutively examined patients with histologically confirmed malignancy who underwent bone scintigraphy, 112 (41%) required further workup by SPECT because a definite diagnosis could not be established using whole-body planar scintigraphy alone. In 57 of these patients, SPECT was accompanied by inline CT over the body region of interest; the remaining 55 subjects underwent only stand-alone SPECT for logistic reasons. The 57 SPECT/CT studies were retrospectively evaluated by readers who were unaware of the clinical pretest probability and the findings on the planar scans. In total, 52 lesions in 44 patients were rated as indeterminate on the SPECT images. Afterwards, the corresponding SPECT/CT images were analyzed and the findings previously rated as indeterminate were classified either as definitely benign, indeterminate, or definitely malignant. RESULTS: Of the 52 indeterminate findings on SPECT, 33 (63%) could be correlated with benign findings on CT. These findings involved mostly osteochondrosis, spondylosis, and spondylarthrosis of the spine. Fifteen lesions (29%) could be correlated with osteolysis or sclerotic metastases on CT. Even after analysis of the SPECT/CT images, 4 lesions (8%) remained indeterminate. These lesions were in the ribs and the scapula. CONCLUSION: SPECT-guided CT was able to clarify more than 90% of SPECT findings classified as indeterminate in an analysis that was masked as to clinical pretest probability and the planar scan findings. Further studies carefully addressing the cost efficiency of this new technology and its actual clinical value are encouraged by this observation.

Bone and Bones↗

Usefulness of multidetector row spiral computed tomography with 64- x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses.

Eighty-four patients with suspected coronary artery disease were studied to determine the accuracy of noninvasive coronary angiography using a multidetector computed tomographic scanner with 64- x 0.6-mm collimation and 330-ms gantry rotation. All coronary artery segments with a diameter >1.5 mm were assessed with respect to stenoses >50% decreased diameter. Results were compared with quantitative coronary angiographic findings. After exclusion of unevaluable coronary segments (4%), multidetector computed tomography demonstrated a sensitivity of 93%, a specificity of 97%, and a negative predictive value of 100% in a per-segment analysis. In a per-artery analysis, 15 of 336 arteries (4%) were unevaluable. Sensitivity and specificity in evaluable arteries were 95% and 93%, respectively. In a per-patient analysis (81 of 84 patients included), sensitivity and specificity were 96% and 91%, respectively.

Adult↗

Contrast-enhanced MR angiography of peripheral arteries including pedal vessels at 1.0 T: feasibility study with dedicated peripheral angiography coil.

PURPOSE: To prospectively determine feasibility of contrast material-enhanced magnetic resonance (MR) angiography of the peripheral arteries from distal aorta to pedal arteries with a 1.0-T system and a dedicated phased-array coil. MATERIALS AND METHODS: Twenty-seven patients with peripheral arteriosclerotic occlusive disease underwent contrast-enhanced MR angiography with an automatic moving-table technique. In addition, lower-leg and pedal arteries were examined without table movement (hybrid technique). Two radiologists independently reviewed MR angiograms to assess image quality and grade stenosis in 13 segments per leg. Each was blinded to patients' clinical data. Twenty-five of the patients also underwent conventional angiography. Stenosis grade at conventional angiography was assessed by two radiologists in consensus. Interobserver variability for stenosis grade at MR angiography was calculated with Cohen kappa test. Specificity and sensitivity of MR angiography in detection of stenosis of more than 50% and occlusion were calculated for both observers. The study was approved by the local ethics committee. RESULTS: In 14 of the 27 patients, hybrid technique was superior to moving-table technique because there was less venous overlap (11 patients), fewer motion artifacts (one patient), or both (two patients). In nine patients, there was no difference between techniques; in four patients, moving-table technique was superior. Stenosis grade was analyzed in 698 segments with MR angiography and in 638 segments with both conventional and MR angiography. Kappa analysis of interobserver agreement with MR angiography yielded a score of 0.84. For the 638 segments evaluated with both conventional and MR angiography, observers 1 and 2 assigned same grade of stenosis with both modalities in 558 and 555 segments, respectively. Sensitivity for stenoses greater than 50% and occlusion was 94.4% and 91.1% for observers 1 and 2, respectively, and specificity was 90.6% and 91.3%. More distal runoff vessels were shown with MR angiography in seven cases and with conventional angiography in two cases. CONCLUSION: Contrast-enhanced MR angiography of the peripheral vessels with a 1.0-T system and dedicated peripheral angiography coil is feasible, and in some cases, it provides additional information compared with conventional angiography.

Aged↗

Magnetic resonance angiography of the carotid arteries using three different techniques: accuracy compared with intraarterial x-ray angiography and endarterectomy specimens.

PURPOSE: To compare three different magnetic resonance angiography (MRA) techniques with x-ray angiography and endarterectomy specimens. MATERIALS AND METHODS: Twenty-one patients underwent x-ray angiography, three-dimensional time-of-flight (TOF) focusing on the carotid bifurcation, high-resolution (HR) contrast-enhanced (CE) MRA, and time-resolved CE MRA. Stenoses of internal carotid arteries were evaluated by three independent observers on identical projection of x-ray angiography and MRA. Maximum stenosis grades on MRA were assessed additionally and correlated with endarterectomy specimens in 12 cases. RESULTS: Sensitivity for the detection of severe stenoses was excellent (100%) for all MRA techniques, and specificity was superior for three-dimensional TOF (96.7%) compared with HR CE MRA (80.6%) and time-resolved CE MRA (83.9%). The correlation between x-ray angiography and MRA for all stenoses was slightly superior for three-dimensional TOF and HR CE MRA compared with the time-resolved technique (kappa = 0.87 and 0.86 vs. 0.84). The same trend was seen for the interobserver agreement and for the correlation with endarterectomy specimens. Eleven up to 17 stenoses (depending on the MRA technique) were graded higher using additional projections. CONCLUSION: Three-dimensional TOF MRA yielded even more accurate results than HR CE MRA in grading of stenoses near the carotid bifurcation. Therefore, a combination of both methods seems to be advantageous.

Aged↗

[Pioneers of medical physics--Theophil Christen (1873-1920)].

The Swiss mathematician and physician Theophil Christen was one of the first important pioneers in Medical Physics. He structured the previously confused field of physical concepts and definitions for medical applications of X-rays and paved the way for the modern understanding of dosimetry.

Health Physics↗

[The development of betatrons in the Siemens centers of Berlin and Erlangen].

Starting from the fundaments set by Rolf Wideroe and Max Steenbeck, the first medical betatron was developed by Konrad Gund at the Siemens centre in Erlangen. This was the first highly sophisticated, large-scale technical device in medicine. Over a period of 30 years Siemens has manufactured a total of 137 betatrons with different maximum energies and sold them worldwide to scientific institutes and radiotherapy departments, among them the most prestigious therapy centres in Germany and Europe. Methodological investigations on high energy electrons und ultrahard X-rays have paved the way for the establishment of the modern high-energy radiation therapy. The interdisciplinary and increasingly more biophysics-oriented research on and with betatrons has had a decisive influence on the establishment of the profession of the medical physicist.

Berlin↗

SPECT/Spiral-CT hybrid imaging in unclear foci of increased bone metabolism: a case report.

In bone scintigraphy, the differentiation between degenerative processes and bone metastases is still difficult. Therefore, additional radiological studies are regularly needed after bone scintigraphy. The now introduced hybrid-cameras combining single-photon emission computed tomography (SPECT) and spiral-CT are unique in the sense that they offer the opportunity to correlate the functional information with morphology in one session. We herein present two patients in whom this technological setup allowed a definite diagnosis in scintigraphically unclear vertebral lesions. In a patient with breast cancer, hypermetabolic lesions were clearly correlated with osteolyses. In another patient with synovial carcinoma, spondylosis and spondylarthrosis caused focal tracer uptake in the lumbar spine. In addition to an improved diagnostic accuracy, SPECT/Spiral-CT will considerably abbreviate the diagnostic process.

Adult↗

[Segmental embolization of the gastroduodenal artery in a case of a perforated pseudoaneurysm and gastrointestinal massive bleeding].

We present the history of a woman suffering from an extensive gastrointestinal bleeding due to liver cirrhosis and chronic pancreatitis. Selective angiogram of the celiac artery revealed a pseudoaneurysm of the gastroduodenal artery caused by inflammatory wall penetration. The life-threatening hemorrhage was completely stopped by embolization with three stainless steel coils after microcatheter engagement of the gastroduodenal artery. The particularity of this case is the restricted embolization of the aneurysm vessel segment, so the collateral circulation of the gastroduodenal and pancreaticoduodenal artery could be preserved.

Aneurysm, False↗