PubMed Health⌕ Search

Biomedical subjects

Werner Bautz

Publications and source records attributed to Werner Bautz.

25 records · Page 2Linked to original sources

Peripheral vessels: MR angiography with dedicated phased-array coil with large-field-of-view adapter feasibility study.

At magnetic resonance (MR) angiography with conventional phased-array coils, visualization of the vascular tree from the infrarenal aorta to the pedal arch is not possible in most patients. For this purpose, the authors developed a dedicated adapter with a large field of view that allows coverage of a body length of approximately 1,380 mm. Among five patients with peripheral arteriosclerotic disease, four underwent both conventional angiography and MR angiography. One hundred fourteen vascular segments from the infrarenal aorta to the feet were evaluated. Agreement between findings at conventional angiography and those at MR angiography was 94.7% (108 of 114) for all segments (96.1% [25 of 26] in the abdomen or pelvis, 97.5% [39 of 40] in the thigh, and 91.7% [44 of 48] in the calf or foot).

Aged↗

Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

BACKGROUND: We analyzed the accuracy of multi-detector row spiral computed tomography (MDCT) using a 16-slice CT scanner with improved spatial and temporal resolution, as well as routine premedication with beta-blockers for detection of coronary stenoses. METHODS AND RESULTS: Seventy-seven patients with suspected coronary disease were studied by MDCT (12x0.75-mm cross-sections, 420 ms rotation, 100 mL contrast agent IV at 5 mL/s). Patients with a heart rate above 60/min received 50 mg atenolol before the scan. In axial MDCT images and multiplanar reconstructions, all coronary arteries and side branches with a diameter of 1.5 mm or more were assessed for the presence of stenoses exceeding 50% diameter reduction. In comparison to invasive coronary angiography, MDCT correctly classified 35 of 41 patients (85%) as having at least 1 coronary stenosis and correctly detected 57 of 78 coronary lesions (73%). After excluding 38 of 308 coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery in 77 patients) classified as unevaluable by MDCT (12%), 57 of 62 lesions were detected, and absence of stenosis was correctly identified in 194 of 208 arteries (sensitivity: 92%; specificity: 93%; accuracy: 93%; positive and negative predictive values: 79% and 97%). CONCLUSIONS: MDCT coronary angiography with improved spatial resolution and premedication with oral beta-blockade permits detection of coronary artery stenoses with high accuracy and a low rate of unevaluable arteries.

Adrenergic beta-Antagonists↗

Phase I trial of strictly time-scheduled gemcitabine and cisplatin with concurrent radiotherapy in patients with locally advanced pancreatic cancer.

PURPOSE: Maximal therapeutic gain in xenograft sarcoma and toxicity for jejunal mucosa is time dependent for concurrent gemcitabine and radiotherapy (RT). We used a time-dependent schedule to determine the maximal-tolerated dose and dose-limiting toxicities (DLTs; Grade 4 hematologic or Grade 3 other toxicity). METHODS AND MATERIALS: Patients with pancreatic cancer (n = 33), periampullary carcinoma (n = 1), or bile duct cancer (n = 2) were treated with 3-day conformal RT with 50.4 Gy (tumor, lymphatics) plus a 5.4-Gy boost. Concurrent cisplatin (20 mg/m(2)/d on Days 1-5 and 29-33) and gemcitabine (initially 600 mg/m(2), weekly on Fridays 68 h before RT) were administered. Because of DLT, the doses were reduced to 500 mg/m(2) weekly and then 500, 400, or 300 mg/m(2) on Days 2, 5, 26, 33. RESULTS: DLT occurred at all dose levels of gemcitabine >300 mg/m(2). Fourteen patients were treated at the recommended Phase II dose of gemcitabine (300 mg/m(2)) without DLT. The response to chemoradiation allowed 10 of 30 initially unresectable patients with primary pancreatic carcinoma to undergo radical surgery, including a complete response in 2 cases. CONCLUSIONS: At the recommended Phase II dose, chemoradiation with gemcitabine and cisplatin can be administered safely in pancreatic carcinoma. However, at higher dose levels, toxicity is severe and frequent. Patients with a chance for conversion to resection could benefit from this schedule.

Adult↗

Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography.

RATIONALE AND OBJECTIVES: To compare the image quality of electron beam tomography (EBT) and multislice spiral CT (MSCT) for coronary artery visualization. MATERIALS AND METHODS: Two groups of 30 patients without coronary stenoses were studied by MSCT (4 x 1 mm collimation) or EBT (3 mm slice thickness). Contrast-to-noise ratio (CNR), overall length of the visualized arteries and vessel length free of motion artifacts were measured. RESULTS: Length of visualized arteries was equal in MSCT and EBT. In EBT, longer segments were depicted free of motion artifacts (MSCT: 73%, EBT: 92% of visualized length, P< 0.001) and CNR was significantly higher than in MSCT (15.4 vs. 9.0; P< 0.001). In both modalities, vessel diameters correlated closely to quantitative coronary angiography. CONCLUSIONS: EBT and MSCT permit reliable coronary artery visualization and measurement of vessel diameters. For the used scan protocol, MSCT images had a lower CNR and were more frequently affected by motion.

Aged↗

High-resolution, contrast-enhanced magnetic resonance angiography with elliptical centric k-space ordering of supra-aortic arteries compared with selective X-ray angiography.

BACKGROUND AND PURPOSE: The objective of this study was to evaluate the relative value of high-resolution, contrast-enhanced MR angiography (CE MRA) with elliptical centric k-space ordering compared with intra-arterial x-ray angiography for imaging carotid stenosis. METHODS: Thirty patients with suspected stenosis of the carotid arteries were examined with CE MRA (1.5-T scanner) and x-ray angiography (aortic arch survey and selective imaging of both common carotid arteries). For the first time, not only the extracranial carotid bifurcation but all the vessel segments from the aortic arch to the circle of Willis were assessed by independent investigators. RESULTS: For the internal carotid artery in the region of the extracranial carotid bifurcation, there was a very close correlation between CE MRA and x-ray angiography (sensitivity, 100%; specificity, 92%). The initially suspected overestimation of stenosis on CE MRA in 3 cases was ultimately revealed to be an underestimation on x-ray angiography. CE MRA showed slightly poorer imaging of the basal vessel segments at the level of the aortic arch (because of breathing artifacts) and the intracranial vessel segments (because of small vessel caliber and venous superimposition due to delayed sequence starts). CONCLUSIONS: The MRA technique described here provides reliable results in the diagnosis of carotid stenosis and is thus suitable for replacing the invasive conventional x-ray angiography method in most cases. Further technical developments with regard to spatial resolution are still required for improved visualization of small vessels (terminal carotid branches and intracranial vessels).

Aged↗

Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection.

OBJECTIVE: Although multidetector CT (MDCT) with retrospectively ECG-gated image reconstruction has been shown to permit noninvasive visualization of the coronary arteries, the 125-250 msec required for image acquisition frequently causes motion artifacts. We investigated the influence of a patient's heart rate on the presence of motion artifacts and on accuracy of stenosis detection on contrast-enhanced MDCT. MATERIALS AND METHODS: In 100 patients, MDCT was performed, and ECG-gated cross-sectional images were retrospectively reconstructed. From the 10 data sets obtained for each patient (reconstructed at 0-90% of the cardiac cycle in increments of 10%), we chose the best data set for every coronary artery. The images of the arteries were evaluated for occurrence of artifacts and the presence of high-grade stenosis (diameter reduction exceeding 70%) or occlusions. MDCT results were compared with coronary angiographic findings. RESULTS: Of the 400 coronary arteries, 115 (29%) could not be evaluated because of motion artifacts (n = 84) or other reasons (n = 31). Overall, 51 (49%) of 104 stenoses were revealed on MDCT. For detecting stenosis in those arteries that we could evaluate, MDCT had a sensitivity of 91% (51 of 56 stenoses detected) and a specificity of 89%. As the heart rate increased, the number of arteries that could be evaluated decreased, and overall sensitivity for stenosis detection decreased from 62% (heart rate < or = 70 beats per minute) to 33% (heart rate > 70 beats per minute). CONCLUSION: MDCT can reveal coronary stenoses, but the usefulness of MDCT as an aid in accurately evaluating stenoses decreases as a patient's heart rate increases.

Adult↗