PubMed Health⌕ Search

Biomedical subjects

Werner Saggau

Publications and source records attributed to Werner Saggau.

10 recordsLinked to original sources

Evaluating a new method for maintaining body temperature during OPCAB and robotic procedures.

BACKGROUND: We evaluated the performance of a new temperature management system (Allon Thermowrap, MTRE, Israel) in maintaining normothermia during OPCAB (Off-Pump Coronary Artery Bypass) procedures and Zeus-robotic IMA (internal mammary artery) takedowns. MATERIAL/METHODS: One hundred patients were prospectively randomized to either a conventional temperature management method (thick blanket, warm intravenous fluids, operating room temperature 25 degrees C), or the new Allon Thermowrap system (pads with temperature-controlled water circulation placed on the patient's back, legs, and arms). The mean age, body surface area, total operating time, and OR air temperature were similar in both groups. RESULTS: The Allon Thermowrap system maintained a higher bladder and nasopharyngeal temperature (p<0.05). The SVR decreased (p<0.05) and the cardiac index increased (p<0.05) in patients with a body temperature>35.80 degrees C. Without reaching a significant level, the postoperative blood loss was lower in the Allon Thermowrap group. CONCLUSIONS: The Allon Thermowrap system significantly out-performed conventional techniques in achieving and maintaining normothermia during off-pump and robotic procedures.

Aged↗

Advanced sternal closure to prevent dehiscence in obese patients.

Sternal dehiscence is a frequent complication after cardiac surgical procedures. The objective was to evaluate a novel method for advanced sternal closure compared with standard techniques for preventing sternal dehiscence. Our investigation comprised 100 patients with a body mass index above 32. Patients were randomly assigned to receive either advanced sternal closure with three stainless steel double wires or standard techniques with stainless steel single wires. The incidence of sternal refixation was 6 of 50 patients in the standard techniques group and 1 of 50 in the advanced sternal closure group during a follow-up period of 6 months.

Aged↗

Low-dose international normalized ratio self-management: a promising tool to achieve low complication rates after mechanical heart valve replacement.

BACKGROUND: International normalized ratio (INR) self-management can significantly reduce INR fluctuations, bleeding, and thromboembolic events compared with INR control managed by general practitioners. However, even patients with INR self-management may have an increased risk of bleeding if their INR value is above 3.5. This study evaluated the compliance, clinical complications, and survival of patients after mechanical heart valve replacement with low-dose INR self-management compared with conventional-dose anticoagulation. METHODS: Group 1 (n = 908) received low-dose anticoagulation with a target INR range of 1.8 to 2.8 for aortic valve replacement and 2.5 to 3.5 for mitral or double valve replacement. Group 2 (n = 910) received conventional-dose anticoagulation with a target INR range of 2.5 to 4.5 for all heart valve prostheses. RESULTS: In groups 1 and 2, 76% and 75% of INR values, respectively, were in the target range. Results did not differ according to schooling and age. The rate of thromboembolic events per patient year was 0.18% in group 1 and 0.40% in group 2 (p = 0.210). The rate of bleeding complications was 0.74% for group 1 and 1.20% for group 2 (p = 0.502). In most patients with clinically relevant bleeding, these complications occurred although their measured INR values were below 3.5. The survival rate did not differ between the study groups (p = 0.495). CONCLUSIONS: Low-dose INR self-management is a promising tool to achieve low hemorrhagic complications without increasing the risk of thromboembolic complications. INR self-management is applicable for all patients in whom permanent anticoagulation therapy is indicated. Even INR values below 3.5 can bear the risk of bleeding complications.

Adolescent↗

Relationship between factor XIII activity, fibrinogen, haemostasis screening tests and postoperative bleeding in cardiopulmonary bypass surgery.

We investigated the relationship between factor XIII, fibrinogen, blood coagulation screening tests and postoperative bleeding in 98 patients undergoing cardiopulmonary bypass (CPB) surgery. All patients received aprotinin. Blood samples were collected preoperatively (T1),after termination of CPB (T2),12 h (T3) and 24 h (T4) after surgery to determine FXIII activity, fibrinogen, platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT) and D-dimers (DD). Laboratory results were correlated with the chest tube drainage 24 h after surgery and compared between patients with 24-hour chest tube drain volumes in the lower (Group 1) with those in the upper tertile (Group 3). Median FXIII and fibrinogen levels dropped by 33.9% and 34.2%, respectively, during CPB. No association between FXIII activity and the extent of postoperative bleeding was found. However, chest tube bleeding was significantly correlated with preoperative and postoperative fibrinogen. This was confirmed by comparing Groups 1 and 3. Group 3 patients had significantly lower fibrinogen levels than Group 1 at T1 - T4, although most fibrinogen values were within or above the reference range (medians, g/l: 3.5 vs. 4.0, p = 0.043 at T1; 2.3 vs. 2.7, p = 0.015 at T2; 2.9 vs. 3.3, p = 0.008 at T3; 4.2 vs. 5.2, p = 0.002 at T4). There was also a significant relationship of platelet count, PT and APTT, as measured after CPB (T2), with postoperative chest tube drainage. In conclusion, plasma FXIII activity does not influence postoperative bleeding in patients undergoing CPB surgery. There is however an inverse association between preoperative or postoperative plasma fibrinogen levels and postoperative bleeding. These findings indicate a modulation of postoperative bleeding by fibrinogen levels.

Adult↗

Blood-air interface during cardiopulmonary bypass.

The aim of this study was to compare the systemic blood activation with open and closed perfusion management during cardiopulmonary bypass. In 30 patients undergoing coronary artery bypass grafting, we prospectively studied systemic blood activation, blood loss and the need for donor blood. In 15 patients we used an open venous reservoir consisting of a hard shell venous reservoir with an integrated cardiotomy filter. In another 15 patients we used a totally closed venous reservoir consisting of a collapsible venous reservoir, no coronary suction, modified vent and cell saver. Venous blood samples were collected pre, post and 24 hours postoperatively. Sex, age and perfusion times were identical in both groups. There were no statistically significant differences in concentrations of FXIIa and C3a, amount of blood loss and need for donor blood. Interleukin-6 and Elastase levels showed trends toward a lesser inflammatory reaction in closed venous reservoir patients. Modification of perfusion management with optimized air management does not seem to be an effective strategy in reducing the inflammatory response and influencing the coagulation system in this small cohort.

Adult↗

Atrial cardiomyoplasty in a Fontan circulation.

INTRODUCTION: The Fontan circulation is a direct connection between the systemic veins and the pulmonary artery (PA). Consequently, the pulmonary flow is passive due to the gradient between the right and left atrial pressure. In patients with increased pulmonary vascular resistance, the surgical procedure of atrio-pulmonary connection is therefore prone to failure. The goal of this experiment was to increase the pulmonary flow in an experimental model of a Fontan circulation by performing a right atrial cardiomyoplasty (ACMP). METHODS: In 19 Foxhounds the left m. latissimus dorsi (LD) was mobilised and transferred as a pedicle into the chest. After sternotomy a 'Fontan circulation' was created under cardiopulmonary bypass (CPB) by connecting the right atrium (RA) with the PA by a valveless conduit. The tricuspid valve was closed with a patch. In 11 dogs (group 1) a valve was implanted in the inferior vena cava (IVC) and pulmonary inflow impedance was increased by partial occlusion of the conduit to a gradient of 10 mmHg between RA and PA. In the other eight dogs (group 2) no valve was implanted, but flowmeters were placed in the IVC and the superior vena cava (SVC). In all dogs the RA was enlarged by a fascia lata patch before the LD was wrapped over the RA and stimulated synchronously to the R-wave with burst impulses. RESULTS: After coming off CPB, relatively high central venous pressures (22.5+/-5.8 mmHg) were necessary to maintain haemodynamic stability. With LD-stimulation in a 1:3 mode in group 1, RA pressure (P) increased from 23.1+/-7.7 to 45+/-10.5 mmHg (P<0.001), pulmonary atrial pressure (PAP) from 15.5+/-4.3 to 25.5+/-7.6 mmHg (P<0.001) and central venous pressure increased to 33.1+/-11.3 mmHg (P<0.05). Stroke volume increase from 11.4+/-4.7 to 17.2+/-4.3 ml and peak conduit-flow from 1286.3+/-880.3 to 2329+/-1173 ml/min (all P<0.001). In a 1:1 stimulation mode a pulsatile pressure/flow profile was obtained in the PA-conduit. Furthermore, at higher frequencies of about 120 beats/min muscle relaxation was still fast enough as not to interfere with the RA filling. In group 2 caval flow without stimulation occurred mainly during diastole. However, with LD-stimulation, a strong backflow into IVC and SVC was observed resulting in a less pronounced pressure/flow increase in the PA. CONCLUSIONS: Our experimental model demonstrates the possibility of a 'ventricularisation' of the RA by using the force of the LD. However, the haemodynamic benefit of ACMP was achieved only, when a valve was implanted in the ICV.

Animals↗

Topical application of aprotinin in cardiac surgery.

The aim of our study was to compare a systemic and a local aprotinin application in patients during coronary artery bypass graft (CABG) surgery. The advantage of a topical aprotinin application is seen in the fact that this may not lead to systemic side effects. A prospective, randomized study comprising 97 patients was conducted. A dose of 5 x 10(6) KIU aprotinin was given systemically to 49 patients and four doses of 1.25 x 10(6) KIU aprotinin were applied topically to 48 patients by spraying the substance on the target area (A. mammaria interna region and pericardium). We determined markers for the inflammatory response, coagulation system, standard haematological markers and postoperative complications. Exclusion criteria were defined as surgical bleeding, redo operations, neurological, haematological, liver and kidney disorders. Sex, age, perfusion times, mortality, renal failure and strokes were identical in both groups. Biochemical markers and clinical outcome demonstrated no significant differences between the systemic and local applications. Interleukin 6 and elastase were tendentially higher (p = 0.1) in the local group, but with a high standard deviation in each patient. Our results suggest that there is no difference between the perioperative application of 5 x 10(6) KIU systemically given aprotinin and 1.25 x 10(6) KIU locally applied aprotinin.

Administration, Topical↗

Robotic surgery using Zeus MicroWrist technology: the next generation.

BACKGROUND: The use of computer-animated surgical instruments for various cardiac operations has been shown to be feasible, but to date, the available information regarding the operative and technical details of these procedures is still inadequate. METHODS: We used the Zeus (Computer Motion Inc., Goleta, Calif, USA) telemanipulation system to perform the internal mammary artery (IMA) takedown in 56 patients, in 12 of whom we used the newest model with MicroWristTM (Computer Motion Inc., Goleta, Calif, USA) technology. Port orientation was based on thoracic anatomy, the decisive landmarks being the mammillary line and the axillary line. The distance between ports was at least 9 cm, and the patient's arm was positioned with the left shoulder raised and angulated by not more than 90 degrees. RESULTS: Mean setup time was 44 +/- 18 minutes for the first five patients and 16 +/- 7 minutes for the last five patients, with an overall average of 24 +/- 12 minutes. IMA harvest time at the beginning reached a mean of 95 +/- 23 minutes and decreased to 44 +/- 18 minutes in the last five cases. Average IMA takedown time was 58 +/- 17 minutes. The IMA was patent with a good flow in all 56 patients. CONCLUSIONS: The introduction of robotic technology into clinical routine has resulted in safe procedures with a short learning curve. However, basic training in the modality is a must in order to achieve technical excellence.

Cardiac Surgical Procedures↗

Intracardiac left ventricular support in beating heart, multi-vessel revascularization.

BACKGROUND: Less invasive operation procedures without support of extracorporeal circulation are becoming increasingly important. A basic requirement for good long-term results in such cases is, however, the complete revascularization of the affected coronary vessels. The unsatisfactorily high conversion rate from bypass operations originally planned as off-pump to conventional operations with heart-lung machines, because of the failure to reach the target vessels on the rear wall of the heart through hemodynamic instability led to investigation of the efficiency of a microaxial pump (Impella elect) placed in the left ventricle. METHODS: In a prospective project 15 of 38 consecutive patients selected for coronary revascularization with beating heart had a micro pump transaortically implanted in the left ventricle to support the heart during the operation with a flow rate of 2.5 to 3.9 l/min. RESULTS: With 8 of 23 patients operated on without pump support, the operation had to be converted to conventional methods with a heart-lung machine. Only one patient out of the left-ventricle-supported group had to be further operated on conventionally because of a deep intramyocardial positioned left anterior descending coronary artery (LAD) (p < 0.05). The investigated laboratory parameters, especially creatine kinase (CK), CK-MB isoenzyme, and clotting showed no significant difference. There tended to be a higher blood loss recorded with the pump-supported patients. CONCLUSION: In summary, it appeared that the application of a left ventricular coaxial pump with comparable results seemed to make possible complete revascularization in nearly all patients.

Aged↗