PubMed Health⌕ Search

Biomedical subjects

X Q Jiang

Publications and source records attributed to X Q Jiang.

9 recordsLinked to original sources

ARID1A Mediates ROS-Induced Osteoclast Activation in TMJ Osteoarthritis.

Excessive osteoclast activation drives rapid subchondral bone destruction, serving as a critical early-stage event precipitating temporomandibular joint osteoarthritis (TMJ-OA). Although epigenetic remodeling is widely recognized as an important interface between pathological environmental signals and genomic response, the specific epigenetic mechanisms translating TMJ-OA-associated stimulation into pathological osteoclast activation remain to be elucidated. Here, using a mechanically induced TMJ-OA mouse model, we identify aberrant reactive oxygen species (ROS) accumulation as a critical upstream driver initiating excessive osteoclast activation and subsequent joint deterioration. By integrating transcriptomic and epigenomic analyses, we delineate the chromatin remodeler AT-rich interaction domain 1A (ARID1A) as an essential oxidative stress sensor within the osteoclast lineage. Mechanistically, ROS accumulation induces ARID1A upregulation and recruitment to the Src enhancer, transcriptionally activating Src and amplifying PI3K-AKT signaling to drive pathological osteoclastogenesis. Conditional knockout of Arid1a in myeloid cells effectively abrogates subchondral bone loss and cartilage destruction in TMJ-OA. Translating these mechanistic insights, we engineered an ROS-responsive, osteoclast-targeting hydrogel for the on-demand delivery of an ARID1A-dependent canonical BRG1/BRM-associated factor complex inhibitor, which successfully alleviates TMJ-OA progression. Our findings establish the epigenetic response to ROS accumulation as a key pathogenic mechanism in TMJ-OA and highlight ARID1A as a promising therapeutic target for early disease intervention.

biomaterial(s)↗

[Experimental research of NNB composite in repairing mandibular defects in rabbits].

OBJECTIVE: To study the effects of artificial bone composite of basic fibroblast growth factor(bFGF) with natural non organic bone(NNB)in repairing mandibular defects in rabbits,in order to provide an ideal bone replacement material for clinic. METHODS: 15mm x 6mm bilateral mandibular periosteum bone defects were made surgically in 30 New Zealand adult rabbits and each defect as an experimental unit. The defects were randomly repaired with composite bone, NNB,fresh autogenous bone at 3,6,12 weeks after surgery according to the total random design, blank control group was stayed. Specimens obtained were evaluated with general observation, X-ray as well as computerized histological microscopic analysis. RESULTS: New bone formed and calcified earlier in composite bone and the bone area was greater in the same period than that in NNB. The new bone area in composite bone was still smaller than that of autogenous bone at 6 weeks, while at 12 weeks they had no significant differences. The blank defects were not repaired even in the end. CONCLUSION: Composite bone had sound biocompatibility. It was much better than NNB and can be compared with autogenous bone 12 weeks after operation. So it can be an ideal alternative for bone replacement.

English Abstract↗

Three dimensional measurement of the surface topography of ceramic and metallic orthopaedic joint prostheses.

The comprehensive study of surface topography of the orthopaedic joint prostheses has become very important for analysis of the wear mechanism and the performance life of the joint replacement systems. The aim of the study to investigate "best" methods for the three-dimensional (3D) surface metrology of orthopaedic joint prostheses. Characterization techniques for the identification and evaluation of the functional features of the bearing surface topographies has been provided in previous work. This paper concentrates on addressing issues of measurement and application techniques for assessment of the 3D surface topography of the joint replacement systems by using contacting stylus instruments, atomic force microscopes (AFM), and non-contacting measurement supported by focus detection instruments and phase-shifting interferometers. The techniques are discussed according to different analysis requirements of the orthopaedic joint prostheses. This work also discusses the performances of the instruments in terms of the measurement of femoral heads. Finally, recommendations for acceptable measurement techniques and application for analyzing surface topography of orthopaedic joint prostheses are summarized.

Journal Article↗

[Treatment of nasofacial hemangioma with interventional embolization and pingyungmycin injection].

OBJECTIVE: To investigate a new method with interventional embolization and pingyugmycin injection for treating nasofacial Hemangioma. METHOD: The fillets and coil were used for interventional embolization facial artery, internal maxillary artery, temporal superficial artery, and pingyungmycin injected for 4 patients. RESULT: The tumor and vascular beat in this series of 4 patients were disappeared by follow up of one year. There are not nasal obstruction and epistaxis. CONCLUSION: Treatment with interventional embolization and pingyungmycin injection is a safe and effective method for nasofacial hemangioma.

Adolescent↗

Three-dimensional surface characterization for orthopaedic joint prostheses.

This study attempts to investigate a range of 'better' methods for the characterization of the three-dimensional (3D) surface topography of orthopaedic joint prostheses. In this paper, a new characterization tool for the comprehensive identification and evaluation of functional features of these surface topographies is presented. For identification, the surface topography is investigated in a space-scale space, by employing wavelet analysis. The roughness, waviness and form involved in surface topography are consequently separated and recovered respectively. The multiscalar topographical features are identified and captured. The errors caused as a consequence of three-dimensional measurement methods can be reduced. After identification, the three-dimensional surface assessment techniques previously reported by Stout and co-workers are used for the quantitative evaluation of various surface roughness features of the orthopaedic joint prostheses. Moreover, the functional properties, such as bearing area, material volume and void volume which are significantly effected by large peaks, pits and scratches are studied and the location of isolated peaks, pits and scratches in the different scales is also clearly characterized. In this work, measurement of the femoral heads and acetabular cups is carried out to demonstrate the applicability of the characterization technique for the three-dimensional surface topography of orthopaedic joint prostheses.

Hip Prosthesis↗

Portal dosimetry using a liquid ion chamber matrix: dose response studies.

Current intensive investigations of electronic portal imaging devices (EPIDs) have prompted their potential application to portal dosimetry. In this paper, the progress made in using a commercial liquid ion chamber matrix EPID for portal dosimetry is discussed. The pixel value of the liquid ion chamber element was calibrated against dose by exposing the imager to 6-MV x-ray beams of various intensities obtained with various thicknesses of lead attenuators and a range of source to detector distances. Absolute dose values were determined using an ion chamber on the central axis at the depth of maximum dose in a solid water phantom. The pixel values of the matrix were determined for various field sizes in order to evaluate the dependence of pixel value on dose at those field sizes. It was confirmed that the pixel value was proportional to the square root of the dose rate and was nearly independent of the field size. The 2D pixel values were converted to 2D dose maps in the water phantom after applying a correction for the effect of horns in the flood calibration field. The flood calibration field was used to obtain the relative sensitivity of each pixel. Good agreement was observed (normally better than 1% in relative standard deviation) between the converted dose distribution obtained from the pixel matrix and the direct dose measurement using an ion chamber scanned in a water phantom in regions of shallow dose gradient. For application to on-line portal dosimetry, both the short- and long-term stability of this EPID system were found to be within 1% relative standard deviation.(ABSTRACT TRUNCATED AT 250 WORDS)

Biophysical Phenomena↗

[Hepatic hemodynamic changes in liver cancer patients during intrahepatic arterial angiotensin II infusion induced hypertension and chemoembolization].

In this report, hepatic hemodynamics were studied by pulsed ultrasound doppler during the process of intrahepatic arterial angiotensin II infusion induced hypertension and chemoembolization (IHCE) in 20 liver cancer patients. It was found that at 90 seconds after I-HCE, tumor blood supply increased by an average of 1.786 times while the blood flow of proper hepatic artery decreased to an average of 0.5665 times of its original level. At the same time patients' peripheral blood pressure increased by 3.7kPa. It is evidenced that angiotensin II infusion augments blood flow to tumor region while decreases blood supply in healthy tissues.

Angiotensin II↗

[In situ detection of EBV DNA in various types of carcinomas derived from the nasopharynx and neighboring regions].

A sensitive and reliable technique for in situ hybridization of DNA-DNA with biotin labelled probe on routine paraffin sections was developed. Using BamH I-W fragment of EBV as probe, a variety of biopsies from nasopharynx and its neighboring regions were examined for EBV distribution. It was discovered that the existence of EBV was related to the histological type and degree of differentiation of carcinomas, but not limited to the nasopharynx region. The EBV DNA positive ratios in (1) poorly, (2) moderately and (3) well differentiated nasopharyngeal squamous cell carcinomas, (4) poorly differentiated nasopharyngeal adenocarcinoma, (5) poorly differentiated squamous cell carcinomas derived from palate and (6) tonsil were 39/41, 1/7, 0/3, 2/8, 3/4 and 2/9 respectively. No EBV DNA was detected in other moderately and well differentiated squamous cell carcinomas or benign tumors of the head and neck. EBV DNA was detected in nearly all malignant cell nuclei of positive sections, whereas all morphologically normal and hyperplastic epithelial cells, stroma cells, infiltrating lymphocytes and epithelium in chronic nasopharyngitis were negative.

Adenocarcinoma↗