Three-dimensional surface characterization for orthopaedic joint prostheses.

Abstract

This study attempts to investigate a range of 'better' methods for the characterization of the three-dimensional (3D) surface topography of orthopaedic joint prostheses. In this paper, a new characterization tool for the comprehensive identification and evaluation of functional features of these surface topographies is presented. For identification, the surface topography is investigated in a space-scale space, by employing wavelet analysis. The roughness, waviness and form involved in surface topography are consequently separated and recovered respectively. The multiscalar topographical features are identified and captured. The errors caused as a consequence of three-dimensional measurement methods can be reduced. After identification, the three-dimensional surface assessment techniques previously reported by Stout and co-workers are used for the quantitative evaluation of various surface roughness features of the orthopaedic joint prostheses. Moreover, the functional properties, such as bearing area, material volume and void volume which are significantly effected by large peaks, pits and scratches are studied and the location of isolated peaks, pits and scratches in the different scales is also clearly characterized. In this work, measurement of the femoral heads and acetabular cups is carried out to demonstrate the applicability of the characterization technique for the three-dimensional surface topography of orthopaedic joint prostheses.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

X Q Jiang, L Blunt, K J Stout. 1999. Three-dimensional surface characterization for orthopaedic joint prostheses.. https://doi.org/10.1243/0954411991534807

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement.

In Europe and the USA combined, over half a million people had a hip joint replaced in 2005, contributing to the increasing number of radiotherapy patients with metallic hip prostheses. The treatment plan for external beam radiation therapy is based on the delineation of the anatomy in the planning CT scan. When implanted objects of high atomic number (Z) material are present, however, severe image artefacts are generated in conventional CT, strongly hindering the ability to delineate some organs. This is particularly the case for the planning of prostate patients with hip prostheses. This short communication presents the use of a new imaging modality, megavoltage cone-beam CT, to complement the regular CT for target definition of prostate cancer treatment of patients with hip replacements.

Hip Prosthesis↗

Stem damage during implantation of modular hip prostheses.

Modular hip prostheses are commonly used today. Dedicated surgical auxiliary instrumentation is indispensable. A correct coupling between the prosthesis and the instrument is necessary to avoid damage. Based on a specific commercial design (AnCAFit, Wright Cremascoli Ortho, Toulon, France), the aim of this work was to assess if stem holders of modular prostheses can induce any stem damage, and if so, to identify the features that provide minimal damage. Two different stem holder connector designs were investigated. The surface of the stem cavity was inspected to identify the damage caused by the use of the two connectors after a simulated surgical handling. Both connectors induced some damage, with significantly more damage being caused by a supposedly improved design. Scars due to contact with the stem holder were observed on the stem cavity surface. This may be sufficient to trigger increased fretting damage during service life, causing the production of fretting debris.

Hip Prosthesis↗