PubMed Health⌕ Search

Biomedical subjects

Xianwei Meng

Publications and source records attributed to Xianwei Meng.

3 recordsLinked to original sources

A simple solution route to single-crystalline Sb2O3 nanowires with rectangular cross sections.

We report a simple solution route to large-scale synthesis of uniform, single-crystalline, and well-faceted orthorhombic antimony trioxide (Sb(2)O(3)) nanowires with rectangular cross sections by direct air oxidation of bulk metal antimony (Sb) in a mixed solution made of ethylenediamine (EDA) and deionized water (DIW). The as-synthesized products were analyzed by range of methods, such as XRD, SEM, EDX, TEM, SAED, HRTEM, FTIR, Raman, UV-vis absorption, and photoluminescence (PL) spectra. The as-synthesized Sb(2)O(3) nanowires with rectangular cross sections are usually hundreds of micrometers in length, typically 80-100 nm in width, and 60-80 nm in thickness. The novel room temperature photoluminescence properties of Sb(2)O(3) nanowires with rectangular cross sections displayed a significant UV luminescence with a strong emission band at 374 nm, which was reported for the first time, indicating the as-synthesized products with an optical band gap E(g) = 3.3 eV. It is expected that as-synthesized Sb(2)O(3) nanowires would be a new member of functional materials and used in the manufacture of advanced nanodevices.

Antimony↗

Effects of applied voltages on hydroxyapatite coating of titanium by electrophoretic deposition.

Hydroxyapatite (HA) coatings were deposited on titanium substrates by electrophoretic deposition (EPD) at constant voltage and dynamic voltage, respectively. Various surface morphologies were observed under different type of voltages. Under a constant voltage of 20 V, a dense HA coating could be prepared. Under a constant voltage of 200 V, big HA particles were deposited and the coating was porous. Under a dynamic voltage, a continuous gradient HA coating could be obtained. HA coatings were characterized with a field emission-scanning electron microscopy (FE-SEM) and an X-ray diffraction (XRD). XRD indicated no significant HA decomposition when the coatings were sintered for 2 h at 800 degrees C.

Coated Materials, Biocompatible↗

Using silver nanoparticle to enhance current response of biosensor.

In this paper, we present a simple procedure to increase the sensitivity of a glucose biosensor. The feasibility of an amperometric glucose biosensor based on immobilization of glucose oxidase (GOx) in silver (Ag) sol was investigated for the first time. GOx was simply mixed with Ag nanoparticles and cross-linked with a polyvinyl butyral (PVB) medium by glutaraldehyde. Then a platinum electrode was coated with the mixed solution. The effects of the amount of the Ag particles used, with respect to the current response for enzyme electrodes, were studied. A set of experimental results indicate that the current response for the enzyme electrode containing hydrophobic Ag sol increased from 0.531 to 31.17 microA in the solution of 10 mmol/L beta-D glucose. The time reaching the steady-state current response reduced from 60 to 20s, three times less than those without Ag particles involved.

Biosensing Techniques↗