PubMed Health⌕ Search

Biomedical subjects

Xingde Li

Publications and source records attributed to Xingde Li.

18 recordsLinked to original sources

Optical properties of Au-Ag nanoboxes studied by single nanoparticle spectroscopy.

The optical properties of two Au-Ag nanobox samples with average edge lengths of 44 and 58 nm and wall thicknesses of 6 and 8 nm, respectively, have been studied by single particle spectroscopy. The measurements gave an average line width of Gamma = 306 +/- 7 meV with a standard deviation of sigma = 30 meV for the 44-nm boxes, and Gamma = 350 +/- 9 meV with sigma = 35 meV for the 58-nm boxes. These line widths are much broader than those of gold nanorods with comparable resonance energies. The increased broadening is attributed to a combination of surface scattering of electrons, as well as increased radiation damping for the nanoboxes. Discrete dipole approximation calculations have been performed with and without surface scattering of electrons to compare with the experimental spectra. The calculations confirm that both electron-surface scattering and radiation damping are important effects in this system.

Algorithms↗

Gold nanostructures: engineering their plasmonic properties for biomedical applications.

The surface plasmon resonance peaks of gold nanostructures can be tuned from the visible to the near infrared region by controlling the shape and structure (solid vs. hollow). In this tutorial review we highlight this concept by comparing four typical examples: nanospheres, nanorods, nanoshells, and nanocages. A combination of this optical tunability with the inertness of gold makes gold nanostructures well suited for various biomedical applications.

Biomedical Engineering↗

Fiber-optic scanning two-photon fluorescence endoscope.

We report on the development of a miniature, flexible, fiber-optic scanning endoscope for two-photon fluorescence imaging. The endoscope uses a tubular piezoelectric actuator for achieving two-dimensional beam scanning and a double-clad fiber for delivery of the excitation light and collection of two-photon fluorescence. Real-time imaging of fluorescent beads and cancer cells has been performed.

Endoscopes↗

Real-time in vivo blood-flow imaging by moving-scatterer-sensitive spectral-domain optical Doppler tomography.

We present a moving-scatterer-sensitive optical Doppler tomography (MSS-ODT) technique for in vivo blood flow imaging in real time by using a spectral-domain optical coherence tomography system. In MSS-ODT the influence of stationary scatterers is suppressed by subtracting adjacent complex axial scans before calculating the Doppler frequency shift. We demonstrate that MSS-ODT is a useful technique for accurate determination of blood vessel size by imaging flow in a small capillary tube with a 75 microm inner diameter. The flow profile obtained with MSS-ODT yields a substantially more accurate tube diameter than that obtained with the conventional phase-resolved method, which underestimates the diameter by about 23%. We also demonstrate that MSS-ODT provides improved sensitivity over the conventional phase-resolved method for imaging in vivo blood flow in small vessels in a mouse ear.

Algorithms↗

Ultrafast laser studies of the photothermal properties of gold nanocages.

Au nanocages were synthesized via a galvanic replacement reaction. The extinction peak of these hollow structured particles is shifted into the near-IR compared with the Ag nanocube templates. Energy transfer from the Au nanocages into the surrounding environment (water) as well as the coherently excited vibrational modes of the nanocages were studied by femtosecond pump-probe spectroscopy. The time scale for energy relaxation was found to increase with the size of the particles, with the relaxation time being independent of the laser intensity. The time scales for relaxation are comparable to those for solid spherical gold particles and are consistent with energy relaxation being controlled by heat dissipation in the solvent. The period of the coherently excited vibrational mode is proportional to the dimensions of the nanocages. Intensity-dependent measurements show that in solution the nanocages maintain their integrity up to lattice temperatures of 1100 +/- 100 K.

Gold↗

Non-invasive imaging of carcinogen-induced early neoplasia using ultrahigh-resolution optical coherence tomography.

BACKGROUND AND OBJECTIVE: Improved diagnostics capable of non-invasive detection of early stage carcinogenesis would benefit basic research, and potentially aid in clinical cancer diagnosis and management. The two-stage carcinogenesis protocol is widely used for studying the multi-stage nature of tumor development in mice and provides insight into tumor development in other animal models and humans. The objective of this study was to investigate the feasibility of non-invasive optical coherence tomography (OCT) for in vivo imaging of microanatomical changes in the epidermis and dermis during early carcinogenesis using a mouse skin model. MATERIALS AND METHODS: 10 NIH mice were treated with DMBA and TPA following the well-established two-stage carcinogenesis protocol. OCT imaging of treated skin from live mice was performed at five time points (Week 4-8) after tumor initiation to reveal the structural changes in the epidermis and dermis associated with the earliest, premalignant stages of tumor development. OCT images were compared with histology findings. In addition, OCT signals were quantitatively analyzed to evaluate tissue optical property changes during early carcinogenesis. RESULTS: Early structural changes in the epidermis, dermis and hair follicles during carcinogenesis were clearly delineated in vivo using OCT. OCT images correlated well with histological findings. Quantitative OCT signal analysis revealed a statistically significant change in the extinction coefficient for untreated (40.5 +/- 17.0 mm(-1)) and treated (9.6 +/- 3.6 mm(-1)) mouse epidermis (P < 0.005). The dermis extinction coefficient for the treated mouse skin (3.7 +/- 0.9 mm(-1)) was lower than the untreated one (4.7 +/- 1.6 mm(-1)), but was not statistically significant (P > 0.10). Furthermore, the papilloma extinction coefficient (2.9 +/- 0.3 mm(-1)) was significantly lower than the extinction coefficient for the treated epidermis (P < 0.005) and dermis (P < 0.01). CONCLUSION: OCT is a viable tool for assessing the earliest stages of carcinogenesis and has potential for early detection of neoplasia in skin, as well as in epithelial linings of other organs.

9,10-Dimethyl-1,2-benzanthracene↗

Gold nanocages as contrast agents for spectroscopic optical coherence tomography.

We describe gold nanocages as a new class of potential contrast agent for spectroscopic optical coherence tomography (OCT). Monodispersed gold nanocages of an approximately 35 nm edge length exhibit strong optical resonance, with the peak wavelength tunable in the near-infrared range. We characterized the optical properties of the nanocage by using OCT experiments along with numerical calculations, revealing an absorption cross section approximately 5 orders of magnitude larger than conventional dyes. Experiments with tissue phantoms demonstrated that the nanocages provide enhanced contrast for spectroscopic as well as conventional intensity-based OCT imaging.

Contrast Media↗

Continuous focus tracking for real-time optical coherence tomography.

We report an approach to achieving continuous focus tracking and a depth-independent transverse resolution for real-time optical coherence tomography (OCT) imaging. Continuous real-time focus tracking is permitted by use of a lateral-priority image acquisition sequence in which the depth-scanning rate is equivalent to the imaging frame rate. Real-time OCT imaging with continuous focus tracking is performed at 1 frame/s by reciprocal translation of a rapid lateral-scanning miniature imaging probe (e.g., an endoscope). The optical path length in the reference arm is scanned synchronously to ensure that the coherence gate coincides with the imaging beam focus. The image quality improvement is experimentally demonstrated by imaging a tissue phantom embedded with polystyrene microspheres and rabbit esophageal tissues.

Animals↗

High-resolution optical coherence tomographic imaging of osteoarthritic cartilage during open knee surgery.

This study demonstrates the first real-time imaging in vivo of human cartilage in normal and osteoarthritic knee joints at a resolution of micrometers, using optical coherence tomography (OCT). This recently developed high-resolution imaging technology is analogous to B-mode ultrasound except that it uses infrared light rather than sound. Real-time imaging with 11-microm resolution at four frames per second was performed on six patients using a portable OCT system with a handheld imaging probe during open knee surgery. Tissue registration was achieved by marking sites before imaging, and then histologic processing was performed. Structural changes including cartilage thinning, fissures, and fibrillations were observed at a resolution substantially higher than is achieved with any current clinical imaging technology. The structural features detected with OCT were evident in the corresponding histology. In addition to changes in architectural morphology, changes in the birefringent or the polarization properties of the articular cartilage were observed with OCT, suggesting collagen disorganization, an early indicator of osteoarthritis. Furthermore, this study supports the hypothesis that polarization-sensitive OCT may allow osteoarthritis to be diagnosed before cartilage thinning. This study illustrates that OCT, which can eventually be developed for use in offices or through an arthroscope, has considerable potential for assessing early osteoarthritic cartilage and monitoring therapeutic effects for cartilage repair with resolution in real time on a scale of micrometers.

Aged↗

Optical coherence tomography imaging of the pancreas: a needle-based approach.

A novel, high-resolution, needle-based optical coherence tomography (OCT) device for improving the ability to detect early epithelial dysplasia in solid tissues/organs in vivo is currently in development. An instrument capable of real-time imaging of tissue microstructures in vivo could improve the ability to detect pathologic conditions such as dysplasia, and consequently improve patient outcomes. OCT is an emerging technology that can perform real-time cross-sectional imaging of tissue structures at micron-scale resolution in vivo. OCT has been shown to be effective in the imaging of luminal epithelium, capable of detecting epithelial dysplasia in Barrett's esophagus, and colonic polyps. However, OCT imaging depth with conventional probes is limited to the luminal surface (approximately 1-2 mm). The development of a technology and device that enables high-resolution, real-time imaging of solid tissues beyond 1- to 2-mm deep at or near the cellular level in vivo could improve the diagnosis of diseases of the pancreas and other solid organs.

Diagnosis, Differential↗

Gold nanocages: bioconjugation and their potential use as optical imaging contrast agents.

Gold nanocages of <40 nm in dimension have been synthesized using the galvanic replacement reaction between Ag nanocubes and HAuCl4 in an aqueous solution. By controlling the molar ratio between Ag and HAuCl4, the gold nanocages could be tuned to display surface plasmon resonance peaks around 800 nm, a wavelength commonly used in optical coherence tomography (OCT) imaging. OCT measurements on phantom samples indicate that these gold nanocages have a moderate scattering cross-section of approximately 8.10 x 10(-16) m2 but a very large absorption cross-section of approximately 7.26 x 10(-15) m2, suggesting their potential use as a new class of contrast agents for optical imaging. When bioconjugated with antibodies, the gold nanocages have also been demonstrated for specific targeting of breast cancer cells.

Cell Line, Tumor↗

Using optical coherence tomography to guide articular cartilage ablation.

Current clinical imaging technologies are not capable of accurately resolving the microscopic components of articular cartilage. Optical coherence tomography (OCT) is a recently developed imaging modality analogous to ultrasound--OCT measures backreflection of infrared light instead of sound. In the study reported here, we wanted to determine the efficacy of OCT for monitoring cartilage laser ablation. Real-time imaging was conducted on bovine cartilage ablated by an argon laser in vitro. Image sequences were generated illustrating the extent of tissue degradation postablation. The images accurately correlated with histology. These results indicate that current ablation procedures could benefit from OCT guidance.

Animals↗

Rapid-scanning forward-imaging miniature endoscope for real-time optical coherence tomography.

We developed a miniature endoscope that is capable of rapid lateral scanning and is suitable for real-time forward-imaging optical coherence tomography (OCT). The endoscope has an outer diameter of 2.4 mm, consisting of a miniature tubular lead zirconate titanate (PZT) actuator, a single-mode fiber-optic cantilever, and a graded-index lens. Rapid lateral scanning at 2.8 kHz is achieved when the fiber-optic cantilever is resonated with the PZT actuator. This allows OCT imaging to be performed by fast lateral beam scanning followed by slow depth scanning, which is different from the conventional OCT imaging sequence. Real-time OCT imaging with the endoscope operated in the new image acquisition sequence at 6 frames/s is demonstrated.

Computer Systems↗

Rapid scanning all-reflective optical delay line for real-time optical coherence tomography.

We describe a dispersion-free high-speed scanning optical delay line that is suitable for real-time optical coherence tomography, in particular, when an ultrabroadband light source is used. The delay line is based on all-reflective optics consisting of two flat and one curved mirrors. We achieve optical path-length scanning by oscillating one of the two flat mirrors with a resonant galvanometer. The delay line is compact and easy to implement. A total scanning depth of 1.50 mm with an 89% duty ratio, a maximal scanning speed of approximately 9.1 m/s, and a 4.1-kHz repetition rate has been demonstrated.

Animals↗

High-speed path-length scanning with a multiple-pass cavity delay line.

Techniques for high-speed delay scanning are important for low-coherence interferometry, optical coherence tomography, pump probe measurements, and other applications. We demonstrate a novel scanning delay line using a multiple-pass cavity. Differential delays are accumulated with each pass so that millimeter delays can be generated with tens of micrometer mirror displacements. With special design criteria, misalignment sensitivity can be dramatically reduced. The system is demonstrated to scan 6 m/s at 2-kHz repetition rates. Real-time optical coherence tomography imaging with 500 pixel images at four frames/s is performed. Using a Cr:forsterite laser source, we obtained axial image resolutions of 6 microm with 92-dB sensitivity.

Models, Theoretical↗

Guidance of aortic ablation using optical coherence tomography.

PURPOSE: There is a significant need for an imaging modality that is capable of providing guidance for intravascular procedures, as current technologies suffer from significant limitations. In particular, laser ablation of in-stent restenosis, revascularization of chronic total occlusions, and pulmonary vein ablation could benefit from guidance. Optical coherence tomography (OCT), a recently introduced technology, is similar to ultrasound except that it measures the back-reflection of infrared light instead of sound. This study examines the ability of OCT to guide vascular laser ablation. METHODS: Aorta samples underwent laser ablation using an argon laser at varying power outputs and were monitored with OCT collecting images at 4 frames. Samples were compared to the corresponding histopathology. RESULTS: Arterial layers could be differentiated in the images sequences. This allowed correlation of changes in the OCT image with power and duration in addition to histopathology. CONCLUSIONS: OCT provides real-time guidance of arterial ablation. At 4 frames, OCT was successfully able to show the microstructural changes in the vessel wall during laser ablation. Since current ablation procedures often injure surrounding tissue, the ability to minimize collateral damage to the adjoining tissue represents a useful advantage of this system. This study suggests a possible role for OCT in the guidance of intravascular procedures.

Animals↗

Detection limit enhancement of fluorescent heterogeneities in turbid media by dual-interfering excitation.

We report on a quantitative comparison between the single-source and the dual-interfering-source configurations for the detection of fluorescent heterogeneities embedded in a piecewise highly scattering homogeneous fluorescent background. The study is based on simulations with analytical solutions of the frequency-domain fluorescent diffuse photon density waves and practical signal-to-noise ratio considerations. Results show that dual-interfering sources outperform single-source techniques for the detection of heterogeneities in terms of fluorophore concentration and lifetime contrast. To detect the same inhomogeneity, less concentration and lifetime contrast is required with dual-interfering sources.

Coloring Agents↗

Noninvasive assessment of cutaneous wound healing using ultrahigh-resolution optical coherence tomography.

Ultrahigh-resolution optical coherence tomography (OCT) was used for noninvasive in vivo evaluation of the wound healing process. Cutaneous wounds were induced by 2.5-mm diameter full-thickness punch biopsies on the dorsal surface of seven mice. OCT imaging was performed to assess the structural characteristics associated with the healing process. The OCT results were compared to corresponding histology. Two automated quantitative analysis routines were implemented to identify the dermal-epidermal junction and segment the OCT images. Hallmarks of cutaneous wound healing such as wound size, epidermal migration, dermal-epidermal junction formation, and differences in wound composition were readily identified on the OCT images. Blister formation was also observed. Preliminary findings suggest OCT is a viable tool to noninvasively monitor wound healing in vivo.

Algorithms↗