PubMed HealthSearch

Biomedical subjects

Y Parikh

Publications and source records attributed to Y Parikh.

5 recordsLinked to original sources

Brain death: the evaluation of semi-quantitative parameters and other signs in HMPAO scintigraphy.

The aim of this study was to facilitate the diagnosis of brain death based on semi-quantitative parameters as well as the other scintigraphic signs and symptoms of brain death. Altogether, 72 studies were performed in 54 patients (35 males, 19 females) to evaluate the diagnoses of brain death which were confirmed in 49 cases. Perfusion dynamic acquisition and static imaging were performed after the intravenous injection of 700-900 MBq 99Tcm-hexamethylpropyleneamine oxime (HMPAO). We reviewed the following parameters retrospectively: (1) qualitative visual assessment of the presence or absence of delayed HMPAO deposition in the brain area; (2) qualitative visual assessment of a 'three-pronged fork' of the cerebral arteries during the first-pass study; (3) any evidence of 'hollow skull' during the first-pass study; (4) any evidence of 'hot nose'; (5) blood flow index (i.e. the ratio of the area under the brain time-activity curve vs that under the curve for the carotid arteries); and (6) delayed uptake index (i.e. the ratio of HMPAO deposition in the brain vs that in the facial regions of interest). We were able to demonstrate the validity of individual signs and symptoms and to confirm the highly reliable nature of semi-quantitative scintigraphic parameters.

Adolescent

Kidney volume estimation using 99Tcm-DMSA RSPECT: evaluation by phantom study.

Renal parenchymal volume is important for clinical interpretation. The phantom study was carried out to validate the volume calculation. The volume of kidney phantom was determined using reoriented single photon emission computed tomography (RSPECT). The phantom volume range was 20-300 ml. There are two major factors in the determination of volume which are radioactivity concentration and organ/background ratio. Our results showed that the effect of radioactivity concentration on the volume in the kidney phantom is -3.3 to 7.5% whereas the effect of organ/background ration was only 2.2%. Our relative volume deviation, therefore, from the real volume was 1.43%. We concluded that it is feasible to use kidney volume in clinical work.

Evaluation Studies as Topic

Comparison of planar and SPECT 99Tcm-dimercaptosuccinic acid scintigraphy in calculating differential kidney function.

An extensive study to compare planar and single photon emission computed tomographic (SPECT) 99Tcm-dimercaptosuccinic acid (DMSA) determination of differential kidney function (DKF) has been carried out. The study has demonstrated that it is possible to use SPECT differential kidney function in place of that obtained using planar scintigraphy. The SPECT DKF value correlated with the planar DKF value. Gradient shaded three-dimensional surface images, reoriented transaxial, sagittal and coronal slices were produced during the same processing method.

Adolescent